PE physical foaming insulated coaxial RF cable SYWV(Y)-75-5
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product properties:
Uses: This product is applicable to shared antenna systems, closed circuit television system and other signal transmission, and such cable has the characteristics of small attenuation and strong anti-interference
Structure and size of YWV (Y) PE physical foaming insulated coaxial RF cable products
Items | Sizes | ||||
SYWV(Y)-75-5 | SYWV(Y)-75-7 | SYWV(Y)-75-9 | SYWV(Y)-75-12 | ||
Inner conductor diameter | 1.00±0.02 | 1.66±0.02 | 2.15±0.03 | 2.77±0.03 | |
Outer diameter of foaming medium (insulator) | 4.80±0.20 | 7.25±0.20 | 9.00±0.25 | 11.50±0.30 | |
Outer conductor | Aluminum-plastic composite belt or aluminum foil + tinned soft copper wire braiding, and the nominal diameter when the tinned copper wire is used in braid | 0.12~0.15 | 0.12~0.15 | 0.12~0.18 | 0.12~0.20 |
The maximum diameter braided angle of outer conductor ≤ 45 °, filling factor of 0.23 (minimum) | 5.8 | 8.3 | 10.1 | 12.6 | |
Jacket | Thickness | 0.70 | 0.85 | 0.96 | 1.00 |
Outer diameter | 7.2±0.30 | 10.3±0.30 | 12.2±0.40 | 15.40±0.40 | |
Delivery length | Length of each volume | 100 | 100 | 200 | 200 |
Short break | 20 | 50 | 50 | 50 | |
As for length of each conducting wire of -7, -9, -12, the order requirements shall prevail |
Electrical performance of SYWV (Y) polyethylene physical foaming insulated coaxial RF cable products
Items | Sizes | ||||
SYWV(Y)-75-5 | SYWV(Y)-75-7 | SYWV(Y)-75-9 | SYWV(Y)-75-12 | ||
Core cable dielectric strength | 1.6 | 1.6 | 1.6 | 1.6 | |
Insulation Resistance 500V DC > | 10000 | 10000 | 10000 | 10000 | |
Sheath dielectric strength | Spark test | 3.0 | 5.0 | 8.0 | 8.0 |
Water immersion test | 2.0 | 3.0 | 5.0 | 5.0 | |
Characteristic impedance 200MHZ | 75±3.0 | 75±2.5 | 75±2.5 | 7.5±2.0 | |
Voltage decrease constant | 50MHz | 4.9 | 3.1 | 2.6 | 2.0 |
200MHz | 9.9 | 6.5 | 5.2 | 4.1 | |
550MHz | 16.8 | 10.7 | 8.5 | 6.7 | |
800MHz | 21.0 | 13.9 | 11.5 | 92 | |
Return loss | VHF | 20 | 20 | 20 | 23 |
VHF | 18 | 18 | 18 | 20 |
- Q: Did not find the relevant norms. Fiber optic cable should not be affected by interference, electric corrosion this piece without taking into account? More
- Cable bridge at both ends to be installed across the ground wire, ground wire diameter can not be less than 16mm2. Wire ends and wire ends of the middle box to be installed at both ends of the ground wire, grounding wire diameter can not be less than 6mm2. Full length bridge with the grounding system connected to not less than 2. Cable bridge is divided into trough, tray and ladder-type, mesh and other structures, by the bracket, arm and installation accessories and other components. Can be set up independently, can also be attached to a variety of structures (structures) and corridor stent, reflecting the structure is simple, handsome in appearance, flexible configuration and easy maintenance features, all parts are required galvanized, installed in the building Outside the bridge, if it is in the vicinity of the sea or belong to the corrosion area, the material must have anti-corrosion, moisture resistance, good adhesion, high impact resistance of the physical characteristics. According to the relevant provisions of the specification, galvanized cable bridge for a good grounding. galvanized cable tray direct board each fixed bolt contact resistance should be less than 0.005Ω, then the cable bridge can be used as a ground trunk (dusting cable tray should not be used as a grounding line), the resistance of each cable bridge can be the following formula Calculate: r = ρ · L / S where: ρ = 15 × 10Ω-6 / cm (20 ℃); L = length calculated by 100mm; S = cross-sectional area of ??cm2. The unit resistance value of the ladder on the pallet is shown in Table 2. The unit resistance value of the cable duct is shown in Table 3 The resistance of each ladder (or each cable slot) after the installation of the cable tray is the total: R = R (r + 1 / 3r ') where: R - ladder, that is, (cable trough) total length of the total resistance (mΩ); r - ladder unit length resistance (mΩ / m)
- Q: Does it also come with the cable that connects it to the monitor? Thanks!
- Yeah, it comes with a three prong power cable and a bunch of internal cables, one or two for the motherboard, one or two for graphics cards, and a bunch for drives.
- Q: It is a Gateway Desktop AMD Athlon 64X2 4200, 2048 DDR2, running Win XP Media center edition with Update Rollup 2. It first started when I put it in quot;stand-bymode and the computer refused to wake up. It has now gotten so bad I have to unplug the power several times with waiting periods in-between, before it will start up. I don't know much about computers but have been reading and trying different set-ups as I read about possible causes. If anyone can help, I'd appreciate.
- its a dodgey PSU....get a new 1...( or take it to a shop and get it fitted if u dont know what ur doing)
- Q: when you install a power cable you usually route it through the door seal and under the carpet. If there are existing speaker wires that go to your rear speakers, will the power cable create an interference?
- I have my power wire and speaker wires touching each other under my carpet. no interference at all. I'll say that it may be possible, I have just never experienced it. So I would say that it won't interfere with your speaker wires. Actually I have my power wire, all speaker wires, and the Remote wire right next to each other. no problems at all.
- Q: ok, i want to install and upgrade the sound system in my car, volkswagen 2006, but i dont know where to run the power cable from the battery in engine compartment to the trunk where i place the amplifiers, anyone who knows, please help me out. thanks
- Think outside the box. Literally. You don't have to go through the passenger compartment...you can run the wires under the vehicle. Just be sure to tie them up well. Good luck.
- Q: I have a 2003 Honda Accord. I'm trying to put an amp and sub in it. My problem is, I'm not sure how to get the power cable from the batter to the inside of the car. I know it needs to go through the firewall, but I need to know exactly where. I couldn't find any unoccupied holes. I also need to know where the other side of the hole will be so that I can grab the wire from the other side. Pictures would be really great if you have them.
- completely authentic, i found out as quickly as I left domicile for greater then in basic terms a month or 2.. there is truly no such place that would make you experience like domicile different than your place of birth or usa.
- Q: Some said that living near the power cable line might cause cancer because of the radiation from this powerline. Please help me decide. Thanks.
- I grew up in Scarborough, this isn't any longer that undesirable! yet Kennedy Station is unquestionably no longer one among its' highlights. I observed a guy get stabbed there as quickly as. attempt to no longer stay very close to a station if obtainable. Meadowvale and Ellesmere is quite super, I lived there and this isn't any longer impossible to get to Kennedy or different public shipping. North York is greater advantageous.
- Q: I recently purchased a Nvidia 8300gs for PCI-E x16.I know that not all graphics cards need a power cable but i'm going to buy one partially because the seller said PCI-E power cable required so is this a common item? would i be able to pick one up at best buy?
- If okorder and order it online, they might not have them at Bestbuy.
- Q: What fuse should I use to run my power cable to the amp?
- Measure the current (A) drawn in operation, increase by 50% and round up to the nearest standard ampacity: If the drawn current in normal operating conditions is 10A @ 12Vdc, 10*1.5 = 15A, which is one of the standard fuse ampacities (no need to round up).
- Q: I recently bought a 750watt power inverter and there are two small cables to connect to it that look like small jumper cables. Can i connect my regular (longer/bigger) jumper cables to the car battery and connect the other end to the inverter cables??Ive been told that this will blow the inverter, and i've been told otherwise. Please let me know if you've had any experience doing this.Thanks,
- That's fine for a temporary use situation. However, if you are going to be using this regularly in the same vehicle, I would recommend a more permanent installation using 4 ga power wire directly to the positive terminal of the battery. Make sure you install a fuse on that wire as close to the battery as possible. If the jumper cables are cheap and thin, or the contacts are coroded or not making good contact, this can cause the voltage to drop to your inverter and cause it to draw more current and possibly fry the power supply.
Send your message to us
PE physical foaming insulated coaxial RF cable SYWV(Y)-75-5
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords