• STA/SWA/AWA armour High voltage XLPE cable System 1
  • STA/SWA/AWA armour High voltage XLPE cable System 2
STA/SWA/AWA armour High voltage XLPE cable

STA/SWA/AWA armour High voltage XLPE cable

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
500 m
Supply Capability:
50000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

STA/SWA/AWA armour High voltage XLPE cable

 

General Conditions

Rated Voltage: 3.6/6kv,6/10(11)kv,8.7/10(15)kv,12/20(24)KV,18/30(33)kv,26/35kv.

Conductor: Cu or Al.

Insulation: XLPE.

Armor: (Stainless)Steel tape armored,(Stainless) steel wire armored,Aluminum wire armored.

Jacket: PVC/PE

Usage: Construction,underground

Standard: IEC0502,IEC60228 for conductor,other standards allowed.

 

1.Usage

This product is suitable for use in rated AC voltage (U0/U)6/6-26/35KV system transmitting and 

distributing lines.According to different sheath make ups,they can be used for laying in the air(cable bridges,indoor well supports and groove boxes) and in soil (direct burying,cable canals

and pipe lines,etc).

 

2.Properties and functions

For XLPE insulated power cable,either chemical method or physical method had been employed to transform the 

molecular structure of PE from linear chain into three dimensional network,that is thermoplastic PE had 

been transformed into thermosetting XLPE.

After crosslinking,the heat mechanical properties of the cable have been greatly improved while its excellent electrical 

properties are still maintained.

The nominal conductor operating temperature of XLPE insulated power cable is 90 degrees.

The cable has the advantages of simplicity in construction,lightness in weight beside its excellent electrical,heat mechanical and anti-chemical corrosion properties.

It can also be laid with no limitation of level difference along the route.

 

3.Properties of applications

1).Max.permissible continuous operating temperature f conductor of 6~35KV cable shall not exceed 90 degrees.

2).Conductor short circuit temperature should not be exceed 250degrees. Max.sustaining period not exceed 5 seconds.

3).Bending radius:

 a).Bending radius of single core cable:20(d+D)±5%.

 b).Bending radius of multi-core cable:15(d+D)±5%.

 c).D is actual outer diameter of cable sample(mm),d is actual diameter of the conductor(mm).

4).Not restricted by the difference of level along the route.

5).Insulation temperature:it should be heated while ambient temperature is below 0 degree.

STA/SWA/AWA armour High voltage XLPE cable

Q: What kind of cable does the power cable 3 (1 * 240) +2 (1 * 120) Is it a separate cable?
The size of the jumper varies with the specifications of the bridge, which is uncertain; the so-called repetitive ground is at least two that is the beginning and end of the end, if the length is enough, the need for intermediate isolation to do the appropriate length of the ground. Stressed that a certain attention to the ground is connected to the power grid on the ground, not directly into the ground.
Q: What is the name of this computer psu power adapter cable from psu to 9600 graphics card....?
PCI express 4 pin to 6 pin power adapter it takes the 2 4 pin molex connectors that connect to a fan or a CD rom or hard drive/ect into 1 pci express 6 pin adapter. People use them if they don't have the 6 pin pci express on their power supply they use the adapter to connect extra 4 pin molexes to use for their video card/devices
Q: Hi. I have a Marina Power Filter (Slimline S15) and the power cable that is connected to it appears to need to be submerged in the water. That doesn't seem safe at all but the instructions (although poorly written) seem to point to that being the case,Advice please.
First, I would get a filter that you trust, I have Stingray 15 by Elite, and the cables of that are submerged as well. Although the cables are wrapped in a waterproof and insulated tube so no water cannot get in and the electricity cannot get through to the water and kill the fish. So the cables are not a problem if you have a trustworthy filter.
Q: Ok, i know it is definitely a NO-NO to run my power cable through walls, but, what if I run the power cord through only to pull it out behind my entertainment center from the wall-plate my other cables come out, and plug in a surge protector?
Try running a plastic conduit on the face of the wall and paint it the color of the wall instead.
Q: I live in Chicago, and I want to know if somebody can help me. The next house on mine have electrical power cable, telefon and cable from my back yard and pas my propriety aprox 60 tf, the last two stay on my garage, its legal ?Know haw i can do to move the cable? some codes or regulation, samething? Thanks, Best regards.
I do not know the codes or regulations in Chicago but i do know in most states it against the law to have power lines resting on a structure. Those two lines resting on the garage could be the cable and phone company's and that is not against the law. However you could call the phone company and cable company and ask them to move them for you. If you can make a valid point that those lines are causing you harm or disturbing you in anyway possible then the company's will have to move it. And for the power cables there is probably nothing you can do unless it is really resting on your garage. But they will just tighten the line and not actually move it.
Q: i bought a new graphics card a while ago, an nvidia 9400gt (i now realize how LOL that is). i connected it, but i noticed there were no extra power cables hanging around that would fit on the small six pin slot on top of the card. the performance increase has basically been negligible, and i don't really want to mess with the power box. should i take it into a computer shop, or is there an easier solution?yes, i installed it correctly and everything. i'm 100% sure.
i does not subject with a GT220 or GT240, they are not lots better if no longer worse than the cardboard you have already. those are not gaming enjoying cards, they're particularly for video accelerating etc. Get a HD 4850 in case you will stumble on one, if no longer maybe a HD 5750 which grants comparable overall performance, yet i does not bypass above this as you will start to be bottlenecked via your processor. maximum enjoying cards merely take one 6pin connection, the only exception being the perfect end enjoying cards such because of the fact the Nvidia GTX 470 or ATI HD 5870. desire i've got helped ;)
Q: Please i need help
u can find about your power supply cable . its hp parts direct store number.
Q: And my other drive has the only analog audio cable on my motherboard hooked up to it, and i know i need to plug in one more cable, because windows wont start up the way i set it up and idk what needs to go into which port.
Are your drives IDE, SCSI or SATA? If they are IDE, are the jumpers set correctly for master/slave or cable select?
Q: power supply, however it comes with some cables that can be attached to the peripheral 4 point cable then ran into the card itself. can this setup work? Or will I need a new power supply with 2 6 point pci express power cables? Oh by the way its a 600 watt power supply I currently have.
i think you should be ok
Q: My amp was working this morning. On my way home, the power cable came out somehow. I put it back in and it wasn't powering on. The amp fuses were blown, I replaced them. Then I went to hook the battery terminal back and the fuse in my power cable blew instantly. I replaced it and tried again and it blew again. Also the fuses in the amp are fine now. I did the same process when I installed my amp the first time and it was fine so I don't know why it's doing this now. The amp is a Boston Acoustics 800w RMS amp and an 80a fuse. Any ideas?
you got a short to ground, make sure ANY part of the Positive (hot) wire is not touching the chassis

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches