Specifications

400sq mm power cable High-voltage 110~220KV XLPE insulated electrical cable copper cable made in China
manufacturer's price

400 sq mm power cable High-voltage 110~220KV XLPE insulated electrical cable copper cable made in China  

Brief introduction of the 110~220KV XLPE high-voltage cable products

1. The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PVC sheathed power cable.

Type

YJLW02,YJLLW02

Specification

240mm2~3000mm2

Voltage

110~220KV

Usage

Suitable for damp areas and the places with a lower underground water level and to be used underground, in tunnels or pipes. Such cables bear a bigger pulling force and pressure.

2. The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PE sheathed power cable.

Type

YJLW03,YJLLW03

Specification

240mm2~3000mm2

Voltage

110~220KV

Usage

Suitable for the places with a higher underground water level and to be used underground, in the tunnels or pipes. Such cables bear a bigger pulling force and pressure.

Structure diagram of the 110KV~220KV XLPE high-voltage cable product

  1. Circular or sliced conductor

  2. Conductor screen

  3. Insulator

  4. Insulated screen

  5. Waterproof buffer layer

  6. Metal sheath

  7. Outer-sheath & semiconducting layer

Specific property for usage of 110KV~220KV XLPE high-voltage cable

  1. Cable’s conductor highest working temperature is allowed up to 90, and overload when meet an emergency is 130 ,When short circuit (in 5 seconds) the highest temperature is 250

  2. When installing or laying cable, the ambient temperature should be less than -20, and have to give a preheat to cable.

  3. The minimum bending diameter:

                Cable type

Bending diameter

Metal sheathed

After laying

30D0

During laying

40D0

Note: In form, D0 is a real test value to cable’s outer diameter.

 4.  Allowed biggest axial traction force to outer diameter when laying cable (not consider the radial lateral-pressure at bent section) T=K×core NO. ×section (kg), in formula, the coefficient K value should be: the copper core get 7, the aluminum core get 4.

5.   Allowed biggest lateral-press P, when cable is being bent

The single core cable is required P500kg/m.

P=T/R (T is indicated axial traction force; R is indicated radius of bent-wheel), Knowing from above formula, as the traction force is made up by length and weight of cable. So it lets P to applying requirement as above. Then the diameter of bent-wheel should be widened.

6.  Cable laying is not being restricted by drop.

The structure parameter and functions table to 110KV, 220KV XLPE high-voltage cable products

  1. Rated voltage 64/110KV XLPE copper core and PE insulated wrinkled aluminum wrapper waterproof layer PE(or PVC) sheathed power cable.

Type: YJLW02(or YJLW03)   Specifications: 1×240mm2~1×1200mm2

Conductor section mm2

Conductor diameter mm

Insulator thickness mm

Aluminum wrapper mm

Sheath thickness mm

Cable’s outer diameter mm

kg/km

Cable’s weight

PVC sheath

PE sheath

240

18.4

19.0

2.0

4.5

89.9

8348

7708

300

20.6

18.5

2.0

4.5

91.1

8990

8341

400

23.8

17.5

2.0

4.5

92.3

9731

9073

500

26.6

17.0

2.0

4.5

94.5

10882

10208

630

30.0

16.5

2.0

4.5

96.9

12352

11660

800

34.0

16.0

2.0

4.5

99.9

14168

13454

1000

38.2

16.0

2.0

4.5

105.0

16460

15708

1200

42.6

16.0

2.0

4.5

109.4

18685

17900

Conductor section mm2

(Ω/km)

Conductor resistance

Capacitance μF/km

Carrier current capacity A

Short circuit current

20℃DC

90℃AC

Conductor

Metal sheath

240

0.0754

0.0961

0.135

543

20

22

300

0.0601

0.0766

0.146

597

25

22

400

0.0470

0.0599

0.165

657

33

22

500

0.0366

0.0467

0.182

718

41

23

630

0.0283

0.0361

0.201

779

52

24

800

0.0221

0.0282

0.223

837

66

25

1000

0.0176

0.0224

0.246

914

83

26

1200

0.0151

0.0193

0.266

962

99

27

Note: Current carrier capacity is made up by laying in soil abreast. The axial distances between cables are 200mm. Soil temperature is 25. The working temperature of cable is 90℃. The coefficient of soil heat-resistance is 1.2km/W.

  1. Rated voltage 127/220KV XLPE copper core and PE insulated wrinkled aluminum wrapper waterproof layer PVC (or PE) sheathed power cable.

Type: YJLW02(or YJLW03)   Specifications: 1×400mm2~1×2500mm2

Conductor section mm2

Conductor diameter mm

Insulator thickness mm

Aluminum wrapper mm

Sheath thickness mm

Cable’s outer diameter mm

kg/km

Cable’s weight

PVC sheath

PE sheath

400

23.8

27

2.4

5.0

128.7

14348

13369

500

26.6

27

2.4

5.0

131.5

15697

14696

630

30.0

26

2.4

5.0

132.8

17064

16052

800

34.0

25

2.5

5.0

134.9

18913

17885

......

1800

52.1

24

2.7

5.0

152.0

30214

29050

2000

55.2

24

2.8

5.0

155.3

32548

31359

2200

57.5

24

2.8

5.0

157.6

34643

33436

2500

61.2

24

2.9

5.0

161.5

37958

36719

Conductor section mm2

(Ω/km)

Conductor resistance

Capacitance μF/km

Carrier current capacity A

(KA/3S)

Short circuit current

20DC

90AC

Conductor

Metal sheath

400

0.0470

0.0613

0.120

689

33

46

500

0.0366

0.0485

0.127

763

41

47

630

0.0283

0.0384

0.139

839

52

48

800

0.0221

0.0311

0.153

918

66

51

......

2000

0.0090

0.0128

0.217

1282

165

67

2200

0.0083

0.0121

0.223

1310

182

68

2500

0.0073

0.0110

0.233

1367

206

73

Note: Current carrier capacity is made up by laying in soil abreast. The axial distance between cables are 200mm. Soil temperature is 25. The working temperature of cable is 90℃. The coefficient of soil heat-resistance is 1.2km/W.


Q: What is the power cable accessories used to do?
Shield For uniform conductive wire and insulated electric field, 6kV and above in the high-voltage power cables generally have a conductive shield and insulation shield, part of the low-voltage cable is not set shield
Q: my mac is fairly new, but is not charging. Are mac power cables this bad?..does anybody know if they need to be replaced often?
Umm well we have had our Mac for about 9 months now and we have had to replace it once. So I think so, just like in iPod touches the headphone jack is screwed up.
Q: I'm trying to run a cable and power outlet into a closet for a media space but im not sure how to add the outlets in there. The area where the closet is, is on a wall that has no outlets and behind the closet is a bathroom which has no outlets on that side of the wall either so theres nothing to tap into. please help.thank you.
This is so situation and construction specific that it can't be answered. Anyone answering this would have to be there in order to tell you what the solution is. Tell ya what, give us full mechanical, structural, and electrical blueprints for your house and I'll tell you what to do. LOL. I'm sorry that your question is impossible to answer. I guess the real answer is to find someone handier than yourself.
Q: need to buy for sharp aquas 52 inch flat screen
It's a universal AC power cord. The same one you would use for most other flat panels, desktop pcs, and the PS3. Go to your local Best Buy. They have them in 2 places: Playstation 3 accessories or the PC cable isle in Computers. $10 give or take a couple bucks.
Q: What is the outer diameter of the copper cable 3 * 25 + 2 * 16? What is the cable diameter of 4 * 50 + 1 * 25?
You can use, but look at your LCD TV there is no DVI port or HDMI port, the best use of HDMI port or DVI port, the specific look at your TV size, if your TV support 1080P, it is best to use HDMI or D fans ridicule guest Piji nine Depends on the end VI, because the VGA can only 1080I can not 1080P, with HDMI or DVI display will be better.
Q: Copper and Aluminum are being considered for the cables in a high-voltage transmission line where each must carry a current of 50A. The resistance of each cable is to be .15ohms per kilometer.A. If the line carries power from Niagra Falls to New York (500Km), mow much power is lost along the way in the cable? Compute for each choice of cable materialB. the necessary cable diameterC. mass per meter of cable Please correct if you see anything that may be offSolving for part a:Power = I deltaV, since deltaV was not given IR=deltaVso Power = (I^2)R = 50^2 x 75 = 187.5 kW lt;-- answerR= 75 since R= .15 ohms/ km x 500kmB) resistivity of copper = 1.7 x 10^-8 ohm m resistivity of al = 2.82 x 10^-8 ohm m R = (resistivity x length)/Areawhat do i use for R? is it the 0.15 ohm/km or 75 ohm?using the 75 ohm as R, I get that the radius of the copper wire is 0.0000361 m and the diameter is then 0.0000722.Am i on the right track?
As the resistivity of copper and aluminum are different,to have the the same resistance,the sections are different. The losses per cable are Ri^2 = 0.15*500*50^2 ( just for the sake of completness,the power transmission lines have three cables) If you take lenght 1km you have to use0.15 ohm,which is the same as using 500km and R =75 ohm Be careful to use the same units of lenght in resistivity and distance. You are on the right track
Q: I am looking to replace a broken power cable for my DigiTech RP1000 guitar effects board, but I am curious as to whether I need to find a cable specifically for this device, or if I can look up any cable with an output of 9V AC; 1.3 Amps.
Hi at such low current and voltage it really doesn't matter that much.
Q: I have a hp laptop from south asia. The adapter connects with the laptop and the power cable. The power cable has a 3 round pin plug which says 6A 240V~. On the hp adapter for the input it says: 100-240V~ 1.6A 5-60Hz. It also says Connect Only to Grounded outlets.Now I am in canada. All i know is that here they have 120 V in normal power plugs. Also they have 1 round and 2 rectangular pins to plug in the outlet.I bought this adapter which basically connects the 3 round pin plug into the adapter and the adapter has 3 canadian pins. The thing is that it says 250V 10A on the adapter. So I am not sure if it will hurt my laptop if I use it. I am a bit confused because Canada has 120V and the adapter accepts 250V. The HP adapter has a range from 100-240V. Will this be ok to use since the HP adapter will just convert the 120V into the proper output for the laptop or do I need one the expensice Voltage converters for the laptop?
ok here is what i would do .. (get a cheap 5 dollar volt meter at radio shack or such. ) it dont have to be digital or fancy , just need voltage reads.. unplug the lap top from the cord, plug in the adapter with the cord NOT IN THE COMPUTER. take the volt meter , and set it to read dc voltage 250v or above . read the volts comming out of the end of the cord using the meter.. is it less then 250 volts , then you should be good .. if you dont know how to read a volt meter, or know a handy neighbor with one , who knows how to us it , go ask them to read the cord for you , tell them you need to know the voltage output while connected to canadian power from the cord..
Q: What is the cable for the YJV33 cable?
If there is a mutation in the target fragment, all the dideoxy-terminated fragments that are larger than a certain size corresponding to the mutant position have no wild-type system, and the rate of detection of mutations is improved for each occurrence of multiple changes in the mobility The ddF method overcomes the difficulty of SSCP analysis due to the effect of DNA length on SSCP, and produces a specific single stranded DNA by a dideoxycyclic acid to show that the DNA fragments with suitable length indicate SSCP changes
Q: i hooked up all my 4 gauge power ground cable from the batteries of my truck i passed both of them thru the fire wall but what i was wondering is will i have a problem since its the power ground coming thru the same hole thru the fire wall or will i be all good ? somebodyy help
Make sure the edges of the hole aren't sharp or rough, to prevent the wire insulation being damaged. Usually, the ground wire on the amp is mounted to nearby metal instead of running a line all the way to the engine. Then, you can beef up the wire from the battery to frame in the engine compartment if necessary.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords