Single Stage End Suction Centrifugal Water Pump

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

               Single Stage End Suction Centrifugal Water Pump

1.Single Stage End Suction Centrifugal Water Pump

End Suction Centrifugal Pump complies fully to the European Standard BS EN733 / DIN24255 of performance and dimensions. They are used for pumping clean water or liquids similar to water, achieving wide application on plants, mines, city water supplies, air-conditioning coolers, firefighting system and irrigation. Pumps of the same model have different performance levels basing on different diameter after impeller trimming. Overall the whole series, there are only four sizes of shaft and five of bearing housing. As long as their bearing housings are of the same size, different pumps can interchange chief parts such as shaft, shaft sleeve, shaft seal, impeller nut, etc.

End Suction Centrifugal Pump is also very easy to be installed and maintained. Back pull-out design, driven through flexible coupling, so that pump casing and motor can remain in position while other spare parts are removed.

2.Main Features of Single Stage End Suction Centrifugal Water Pump

very easy to be installed and maintained

Back pull-out design

•Driven through flexible coupling

•Customized design is available, OEM and ODM are welcomed.

•Horizontally and vertically installation as different pipeline system

3.Single Stage End Suction Centrifugal Water PumpSpecification

 

Material

Cast iron

Pump diameter

350-1600mm

Flow range

1~200L/s

Pressure range

0.2~2.25MPa

Motor power range

1.5~200kW

Inlet/outlet Diameter

DN50~DN200mm

 

Casing

Cast Iron Standard, Ductile Iron, Stainless Steel Optional

Impeller

Bronze Standard ,Cast Iron, Stainless Steel Optional

Shaft

ASTM420Standard,ASTM304,ASTM316,ASTM1045 Optional

Shaft Seal

Mechnical Seal, Gland Pakcing Optional

 

Flow rate

2-1100m3/h

Head

2-152m

Speed

1450 or 2900(50hz),1750 or 3500(60hz)

Working Pressure

1.6PMa or 2.0PMa

 

4.Picture of Single Stage End Suction Centrifugal Water Pump

Single Stage End Suction Centrifugal Water Pump

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also provide the pump model you are using now, price will be calculated as per the pump model, if not, we will recommend relevant product for reference.

 

 

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The working principle of magnetic pump
Control of cooling fluid flowThe pump is running, you must use a small amount of liquid in the magnetic separation between the rotor and the casing annulus area and sliding friction bearings for flushing cooling. The cooling liquid flow pump design flow is usually 2%-3%, the annular area between the magnetic rotor and sleeve of eddy current generated because of high heat. When the cooling and lubrication the liquid is not enough or poor flushing holes to plug, will result in permanent magnet medium temperature is higher than the operating temperature of the inner magnetic rotor gradually loses magnetism, the magnetic actuator failure. When the medium is water or water-based liquid, can make the annulus area temperature maintained at 3-5 DEG C; when the medium or hydrocarbon oil that can make the annulus area temperature maintained at 5-8 degrees.
Q:Rotary vacuum pump does not meet the requirements of vacuum, what are the reasons?
(1) pump connected outside pipes, containers, pipes, joints and other leakage test instrument, large leakage, rotary gas plug exhaust sound big, and the gas and oil mist discharge, should find leakage cancellation.(2) the assembly of rubber of intake pipe is not proper, damage or aging should be adjusted or replaced.(3) plug hole, the vacuum degree can be decreased, put the oil, remove the tank, loosen the nozzle plate, pull out the oil inlet nozzle, dredge oil hole, try not to use cotton wipe parts.(4) the vacuum system has serious pollution, including containers, pipes and so on. It should be cleaned.(5) the spring of the vane is broken and should be adjusted.
Q:Suction stroke and lift of water pump
The absorption process is also called the "largest self-priming height" (also can be understood as "the degree of self suction). Micro pumps do not add water at the circumstances, can automatically water suction pump up the maximum height (the vertical distance from the pump to be pumped from the mouth of pumping liquid).Generally lower than the water pump positioned equal when there is self-priming pump required capacity. For example, outdoor tourism, need to extract the water in the river, with the best micro pump self-priming ability (impossible to people ran to the river water inlet pipe with water. It) or pumping the liquid corrosion, easy to add water and so on occasions.
Q:Troubleshooting of diaphragm pump
In the application of the pump, these conditions are likely to encounter. Each situation can be divided into several possible reasons. This guide lists the causes of failures and gives appropriate corrective maintenance measures. The meaning of all the specific terms in the guide is listed later.Air valves - copper or stainless steel valves are bolted to the center of the pump by four bolts.The piston aluminum cylinder is enclosed in the air valve to control the gas flow.Cavitation - because the pump inlet for the amount of fluid to reduce or lack, the pump discharge is less than the amount of quantitative. In fact, the fluid chamber is full of fluid before it is discharged.Static pressure drop - the inlet pressure from the pump centerline to the free point - the inlet is measured in pounds, including the specific gravity and velocity of the fluid.
Q:The water tank of the fish tank does not air out and only has the water outlet
The air inlet pipe is connected with the oxygen burst, the entrance also pulled out, we can see that it is the design of a miter, the oblique incision back to the direction of the water flow speed, this outflow, negative pressure is formed in the oblique incision, the air can be sucked in. As shown.
Q:What's the difference between non negative pressure and variable frequency water pump?
Re pressure to a given pressure pressure zone water supply, than frequency conversion water pump energy savingFrom a health perspective, a water tank variable frequency water pump, water tank and the atmosphere, easy occurrence of water pollution two, no negative pressure equipment without negative pressure tank and pump and valve fittings etc., no water tank, the whole process of water supply of water is completed in a closed system, with air contact to avoid two pollution problems water supply.From the management point of view, no negative pressure is fully automatic intelligent operation, reduce management costs, no water tank, reducing the trouble of tank cleaning. No negative pressure is the upgrading of variable frequency water pump products
Q:What is the difference between centrifugal pump and self suction pump? Which is better?
Centrifugal pumps are vertical, horizontal, single-stage, multi-stage, single suction, double suction, self suction and other forms. The centrifugal pump drives the water to rotate through the high speed rotating impeller blade, and the water is thrown out so as to achieve the purpose of pumping water. The impeller rotates at high speed, forcing the liquid at the center of the impeller to be removed at high speeds, resulting in a low pressure at the center of the impeller, and the liquid in the lower trough is continuously sucked.
Q:What are the differences between the sewage pump and the clean water pump?
Sewage pump is a pump and motor conjoined, and at the same time submerged into the work of pump products, and general horizontal pump or vertical sewage pump compared to the sewage pump compact structure, small footprint.The water pump is for the transport of water and physical and chemical properties similar to water and other liquids used, suitable for the industry and the city water supply and drainage, water pressure high-rise buildings, garden sprinkler, fire booster, long-distance transportation, HVAC refrigeration cycle, irrigation, bathroom, cold and hot water circulation pressurization and equipment.
Q:What is the name of the day pump and ground pump? Specific introduction
PumpGround pumps are used very frequently in many large basements, because they have no boom, so they need to be taken over manually. In addition to the site, for those days to pump the high-rise buildings, such as 200 meters or 200 meters altitude, can also take over to transport concrete by pump, but the premise is to have enough power to pump concrete will hit above the height and the length of nozzle can reach the height of the floor.Thus, the day pump and ground pump have their respective advantages. The pump is easy to use, but the ground pump can make up for the height that the pump can not reach. At the same time, the price is relatively cheap, so users can choose the corresponding concrete pump when they are in use.
Q:What is a solution pump?
2.1 advantages of canned pumps(1) fully enclosed. There is no dynamic seal in the structure. Only the static seal in the outer shell of the pump can be made without leakage. It is especially suitable for transporting flammable, explosive, precious liquids and toxic, corrosive and radioactive liquids(2) high safety. The rotor and stator each have a shielding sleeve, so that the rotor and stator of the motor are not in contact with the material, even if the shield is broken, it will not produce the risk of leakage and leakage(3) compact structure and small footprint, the pump and motor is a whole, disassembly and assembly do not need to find the center. The base and foundation requirements are low, and the daily maintenance workload is low, and the maintenance cost is low

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range