PVC Insulated Wire and Cable of Rated Voltage up to and Including 450/750V
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
PVC Insulated Wire and Cable of Rated Voltage up to and Including 450/750V
Specification
Type | Designation | Rated voltage (V) | Standard |
227 IEC 01 (BV) | Single-core rigid conductor non-sheathed cable for general purpose | 450/750 | GB 5023 |
227 IEC 02 (RV) | Single-core flexible conductor non-sheathed cable for general purpose | 450/750 | GB 5023 |
227 IEC 05 (BV) | Single-core solid conductor non-sheathed cable for internal wiring with conductor temperature of 70℃ | 300/500 | GB 5023 |
227 IEC 06 (RV) | Single-core flexible conductor non-sheathed cable for internal wiring with conductor temperature of 70℃ | 300/500 | GB 5023 |
227 IEC 07 (BV-90) | Single-core solid conductor non-sheathed cable for internal wiring with conductor temperature of 90℃ | 300/500 | GB 5023 |
227 IEC 08 (RV-90) | Single-core flexible conductor non-sheathed cable for internal wiring with conductor temperature of 90℃ | 300/500 | GB 5023 |
227 IEC 10 (BVV) | Light-duty PVC sheathed cable | 300/500 | GB 5023 |
227 IEC 42 (RVB) | non-sheathed parallel flexible cable | 300/300 | GB 5023 |
227 IEC 43 (SVR) | Flexible cable for indoor decorative illumination loops | 300/300 | GB 5023 |
227 IEC 52 (RVV) | Light-duty PVC sheathed flexible cable | 300/300 | GB 5023 |
227 IEC 53 (RVV) | Ordinary PVC sheathed flexible cable | 300/500 | GB 5023 |
BV | Copper conductor PVC insulated cable | 300/500 | JB 8734 |
BLV | Aluminum conductor PVC insulated cable | 450/750 | JB 8734 |
BVR | Copper conductor PVC insulated flexible cable | 450/750 | JB 8734 |
BVV | Copper conductor PVC insulated PVC sheathed round cable | 300/500 | JB 8734 |
BLVV | Aluminum conductor PVC insulated PVC sheathed round cable | 300/500 | JB 8734 |
BVVB | Copper conductor PVC insulated PVC sheathed parallel cable | 300/500 | JB 8734 |
BLVVB | Aluminum conductor PVC insulated PVC sheathed parallel cable | 300/500 | JB 8734 |
RVS | Copper conductor PVC insulated twisted flexible cable for connection | 300/300 | JB 8734 |
AV | Copper conductor PVC insulated wire for internal wiring of equipment | 300/300 | JB 8734 |
AVR | Copper conductor PVC insulated flexible wire for internal wiring of equipment | 300/300 | JB 8734 |
AVRB | Copper conductor PVC insulated parallel flexible wire for internal wiring of equipment | 300/300 | JB 8734 |
AVRS | Copper conductor PVC insulated twisted flexible wire for internal wiring of equipment | 300/300 | JB 8734 |
AVVR | Copper conductor PVC insulated and sheathed flexible cable for internal wiring of equipment | 300/300 | JB 8734 |
AV-90 | Copper conductor PVC insulated wire with temperature rating of 90℃ for internal wiring of equipment | 300/300 | JB 8734 |
AVR-90 | Copper conductor PVC insulated flexible wire with temperature rating of 90℃ for internal wiring of equipment | 300/300 | JB 8734 |
AVP | Copper conductor PVC insulated shielded wire for internal wiring of equipment | 300/300 | JB 8734 |
RVP | Copper conductor PVC insulated shielded flexible wire | 300/300 | JB 8734 |
RVVP | Copper conductor PVC insulated and sheathed shielded flexible wire | 300/300 | JB 8734 |
RVP-90 | Copper conductor PVC insulated shielded flexible wire with temperature rating of 90℃ | 300/300 | JB 8734 |
AVP-90 | Copper conductor PVC insulated shielded wire with temperature rating of 90℃ for internal wiring of equipment | 300/300 | JB 8734 |
NLVV | Aluminum conductor PVC insulated and sheathed direct-buried cable for rural area | 450/750 | JB 2171 |
Description
The product listed is applicable for power installations, fixed wiring and connection of electrical appliance of rated voltage up to and including 450/750V.
The maximum long-term permitted operating temperature of the cables with the type of 227 IEC 07 (BV-90)、227 IEC 08 (RV-90)、AV-90、AVR-90 or RVP-90 and AVP-90 shall be 90℃, and 70℃ for all the other types of cables. The ambient temperature of installation of the cable shall not be less than 0℃.
FAQ
Q:How about your quality?
A:Quality is our culture, our products has to be checked with engineer, QC and sales, customer together, The products’ qualified rate need to be over 95%.
Picture
- Q: VV3 * 120 + 2 * 70 cable what does it mean
- YJV cable is cross-linked polyethylene insulation, VV cable is PVC insulation, the former temperature level higher than the latter, such as the former conductor temperature can be 90 degrees, while the latter can only to 70 degrees!
- Q: Does anyone know where i can find a power cable for sale for a 'Seagate Expansions 500GB External Desktop USB 2.0 Hard Drive ' ?
- Radio Shack or any computer store can sell you a generic replacement power cable for the drive. You can also get a replacement USB cable for it while you're at it in case that cable is wearing out. - Stuart
- Q: I bought a LG Plasma TV, it comes with 3 Ferrite cores, two of them is a little bigger than the diameter of the power plug and it's not tight on it and one is small, is it effective to but the bigger one one the power cable?
- They should be tight or glue to the cable. Many cheap made products ignoring this simple process to speed time consume to produce more. Because those workers were paid by piece work.
- Q: everything was working great! and then i blew the main fuse! i replaced it everything was fine after that but then out of nowhere i only have power in half of the power cable connected to the amp!! What can i do??
- I okorder /... Under the column for 90 degree cable in copper pick the wire gauge that is closest to your amp requirements without being under. For example: 1200 watt amp = 100 amps of power 2 gauge copper can handle 130 amps (This chart is missing 3 gauge which some places do carry, which can handle 110 amps) 4 gauge is only good for 95 amps. These ratings are about heat build up from inductance of the current. When the heat exceeds the rating, the sheathing melts and conductor degrades at it's weakest point. I recommend use of THHN electrical wire. It is gas and oil resistant and has heavy strands that hold up well to the stress of vehicle install situations. If your wire and fuses are properly sized, then check all of your connections. Often times heat and vibration will loosen screws on amplifier contacts. Also, under the hood, heat can melt your fuse holder causing plastic to coat the contact points (in which case you'll need a small file to clean the contacts) There's really a lot of possibilities here and your question is quite vague and convoluted. Please give more details or take some time and analyse the problem carefully. Chances are that you will discover the source of the problem in a matter of just 15 minutes or so of checking.
- Q: I am usng a ripspeed R2100 Amp JMB 1000W Sub speaker the amp has 2 25amp fuses attatched, but I do not know what fuse to use in the main audio power cable, I have been upto 40 amp it blew that, I dont know if I maybe have wire something wrong, can anyone help, thanks
- you always take wat amp fuses you have in the amp and add them all together and thats the minimun fuse amp you can have in your power, your amp has 2 25amp fuses so you need at least a 50amp fuse on ur power wire, and if you have the lil fuses you cant go beyond 40 so youll have to go get a MAXI fuse block and get a 60amp fuse and you will b fine, you can find them on OKorder for less than 10bucks or at walmart for 15-20bucks, good luck
- Q: And twisted pair cable parallel to the laying of the same route with 10kVA 380V power cable, the minimum spacing between the two cables should be how much? Knowledge related to integrated wiring. The The The The
- PLC and computer communication cable, different manufacturers of PLC connection is not the same
- Q: What is the difference between a power cable and a cross-linked cable?
- I do not know, I do the task, although we also engage in cable
- Q: I have a be quiet! dark power pro 850W. The sleeving is too thick for cable management!! It is a complete mess with the antec 900. its ridiculous as I bought it with cable management in my mind. Can I buy thinner cables on their own? Is there a standard modular fitting size?Thank you.
- the capability connectors that plug into the slots on a modular capability furnish are no longer common -- they are particular to that distinctive style of furnish (there is a few standardization for modular PSUs made by a particular producer, yet i does no longer even confirm approximately that). So, in case you opt for further cables, you ought to touch client service on your style of PSU or examine help boards at their internet site to work out what the technique is for paying for them.
- Q: And if so how much would that cable be and could you supply a link to get it from that place?Im really struggling to find any details of where i can get one so could you possibly check out the item and see if there is any help on there?I currently have a 3A 250v Power cable and i'm wondering if that can help?Thanks alot and if it helps ill pick a best answer soon. Thank you!
- High input cable ...? Not really sure what that is, Also, that power supply is junk. 750W and it only has a single 6-pin PCI? That's sad. Good 750W power supplies are at least ?70 and have four 6-pin PCI cables. Heck, a good 430W costs more than that and it's guaranteed to perform better.
- Q: Should I call 911 if a frayed power line fell in my driveway?
- Leave 911 for emergency calls. You should call the power company. Do not approach the cable, and if it is in water, do not step into it !
Send your message to us
PVC Insulated Wire and Cable of Rated Voltage up to and Including 450/750V
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 100000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches