• Open Type Perkins Diesel Generating Set  for Building Use System 1
  • Open Type Perkins Diesel Generating Set  for Building Use System 2
Open Type Perkins Diesel Generating Set  for Building Use

Open Type Perkins Diesel Generating Set for Building Use

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
500 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Open Type Perkins Diesel Generating Set  for Building Use

Founded in 1932 in the United Kingdom, Perkins annual output nearly 400,000 engines.The diesel and natural gas engines are widely used in various industries due to their advantages of economy, reliability and durability.As the world class A certified company, Perkins diesel generator sets have genuine trend internationalization. Today, Perkins has established production departments in 13 countries and formed a global service network consisting of more than 1,000 distribution points and service centers. In the field of power generation, the 7kw-1811kw diesel generator sets have excellent performance, reliability, durability and other advantages.


OPEN TYPE PERKINS DIESEL GENERATING SET DATA SHEET

Genset Model

Standby Power

Prime Power

Fuel Consumption

Overall Size

Weight

Fuel Tank Capacity

Engine Description

Alternator Model

KVA

KW

KVA

KW

100%    L/H

L x W x H (mm)

KG

L

 Model

Oil Capacity(L)

Coolant Capacity(L)

Stamford

ZOP10PK

10

8

9

7

2.6

1500x650x1225

425

160

403A-11G1

4.9

5.2

LSA40VS1

ZOP10PK

10

8

9

7

2.6

1500x650x1225

425

160

403D-11G

4.9

5.2

LSA40VS1

ZOP14PK

14

11

13

10

3.67

1500x650x1225

496

160

403D-15G

6

6

LSA40VS2

ZOP14PK

14

11

13

10

3.48

1500x650x1225

496

160

403A-15G1

6

6

LSA40VS2

ZOP16PK

16

13

15

12

3.48

1500x650x1225

496

160

403A-15G2

6

6

LSA40S3

ZOP22PK

22

18

20

16

5.3

1500x650x1225

610

160

404D-22G

10.6

7

LSA40M5

ZOP22PK

22

18

20

16

5.3

1500x650x1225

610

160

404A-22G1

10.6

7

LSA40M5

ZOP30PK

30

24

27

22

6.7

1500x650x1225

660

160

404D-22TG

10.6

9.3

LSA42.3VS2

ZOP33PK

33

26

30

24

6.98

1650x750x1280

780

221

1103A-33

7.9

10.2

LSA42.3VS3

ZOP50PK

50

40

45

36

10.6

1650x750x1280

887

221

1103A-33T/DK83398S

7.9

10.2

LSA42.3M7

ZOP65PK

65

52

60

48

13.8

1650x750x1280

908

221

1104C-44TG2

8

13

LSA42.3L9

ZOP65PK

65

52

60

48

13.8

1650x750x1280

908

221

1103A-33T/DK83399S

7.9

10.2

LSA42.3L9

ZOP75PK

73

58

65

52

14.8

1750x850x1300

923

221

1104A-44TG1

8

13

LSA44.3S2

ZOP88PK

88

70

80

64

18.4

1750x850x1300

1037

221

1104A-44TG2

8

13

LSA44.3S3

ZOP88PK

88

70

80

64

18.4

1750x850x1300

1037

221

1104C-44TAG1

8

12.6

LSA44.3S3

ZOP100PK

100

80

90

72

20.5

2240x850x1320

1175

300

1104C-44TAG2

8

12.6

LSA44.3S4

ZOP110PK

110

88

100

80

24

2240x850x1320

1190

300

1104C-44TAG2

8

12.6

LSA44.3S5

ZOP150PK

150

120

135

108

29.9

2900x900x1536

1760

685

1106A-70TG1

16.5

21

LSA44.3M8

ZOP158PK

158

126

142

115

39.7

2900x900x1536

1760

685

1106D-E70TAG2

16.5

21

LSA44.3L10

ZOP165PK

165

132

150

120

33.4

2900x900x1536

1760

685

1106A-70TAG2

16.5

21

LSA44.3L10

ZOP175PK

175

140

160

128

42.3

2900x900x1536

1760

685

1106D-E70TAG3

16.5

21

LSA44.3L12

ZOP200PK

200

160

180

144

41.6

2900x900x1536

1796

685

1106A-70TAG3

16.5

21

LSA46.3S2

ZOP200PK

200

160

180

144

49.3

2900x900x1536

1830

685

1106A-E70TAG4

16.5

21

LSA46.3S2

ZOP220PK

220

176

200

160

45.8

2900x900x1536

1830

685

1106A-70TAG4

16.5

21

LSA46.3S3

ZOP220PK

220

176

200

160

44.6

3000x1200x2000

2760

1100

1506A-E88TAG1

41

29.6

LSA46.3S3

ZOP250PK

250

200

225

180

48.6

3000x1200x2000

2760

1100

1506A-E88TAG2

41

29.6

LSA46.3S4

ZOP275PK

275

220

250

200

50

3000x1200x2000

2760

1100

1506A-E88TAG3

41

29.6

LSA46.3S5

ZOP300PK

300

240

275

220

60.2

3000x1200x2000

2860

1100

1506A-E88TAG4

41

33.2

LSA46.3M7

ZOP330PK

330

264

300

240

64.9

3000x1200x2000

2860

1100

1506A-E88TAG5

41

33.2

LSA46.3M8

ZOP400PK

400

320

350

280

70

3200x1206x1980

2932

1200

2206A-E13TAG2

40

51.4

LSA46.3L11

ZOP400PK

400

320

350

280

70

3200x1206x1980

2932

1200

2206C-E13TAG2

40

51.4

LSA46.3L11

ZOP450PK

450

360

400

320

82.7

3200x1206x1980

3069

1200

2206A-E13TAG3

40

51.4

LSA47.2S4

ZOP450PK

450

360

400

320

82.7

3200x1206x1980

3069

1200

2206C-E13TAG3

40

51.4

LSA47.2S4

ZOP500PK

500

400

450

360

95.6

3500x1540x1850

3400

1200

2506A-E15TAG1

62

58

LSA47.2S5

ZOP500PK

500

400

450

360

95.6

3500x1540x1850

3400

1200

2506C-E15TAG1

62

58

LSA47.2S5

ZOP550PK

550

440

500

400

106

3500x1540x1850

3551

1200

2506A-E15TAG2

62

58

LSA47.2M7

ZOP550PK

550

440

500

400

106

3500x1540x1850

3551

1200

2506C-E15TAG2

62

58

LSA47.2M7

ZOP650PK

650

520

600

480

126.6

3500x1540x2050

3813

1450

2806C-E18TAG1A

87

61

LSA47.2L9

ZOP660PK

660

528

600

480

126.6

3500x1540x2050

3813

1450

2806A-E18TAG1A

87

61

LSA47.2L9

ZOP700PK

700

560

650

520

129.3

3500x1540x2050

3925

1450

2806A-E18TAG2

87

61

LSA49.3S4

ZOP825PK

825

660

750

600

152.3

4350x1750x2270

5525

1800

4006-23TAG2A

113.4

140

LSA49.3M8

ZOP880PK

880

704

800

640

171.8

4350x1750x2270

5570

1800

4006-23TAG3A

113.4

140

LSA49.3M8

ZOP1000PK

1000

800

900

720

188

4700x2070x2414

6667

1400

4008TAG1A

153

234

LSA49.3L9

ZOP1100PK

1100

880

1000

800

215.2

4700x2070x2414

6792

1400

4008TAG2

153

234

LSA49.3L10

ZOP1100PK

1100

880

1000

800

215.2

4700x2070x2414

6792

1400

4008TAG2A

153

234

LSA49.3L10

ZOP1250PK

1250

1000

1125

900

237.2

4700x2070x2414

6850

1400

4008-30TAG3

153

234

LSA50.2M6

ZOP1375PK

1375

1100

1250

1000

258.1

4800x2200x2477

9950

3000

4012-46TWG2A

177

187

LSA50.2M6

ZOP1500PK

1500

1200

1375

1100

279.1

4900x2200x2477

10205

3000

4012-46TWG1A

177

274

LSA50.2L7

ZOP1500PK

1500

1200

1375

1100

279.1

4900x2200x2477

10205

3000

4012-46TWG3A

177

187

LSA50.2L7

ZOP1600PK

1600

1280

1500

1200

299

4900x2200x2477

10435

3000

4012-46TWG4A

177

187

LSA50.2L8

ZOP1650PK

1650

1320

1500

1200

299

4900x2200x2477

10435

3000

4012-46TAG2A

177

274

LSA50.2L8

ZOP1875PK

1875

1500

1688

1350

367.3

5100x2200x2477

11200

3000

4012-46TAG3A

177

274

LSA52.3S5

ZOP2000PK

2000

1600

1850

1480

381.3

6100x2740x3120

13780

3000

4016TAG1A

237

368

LSA52.3S5

ZOP2000PK

2000

1600

1850

1480

381.3

6100x2740x3120

13780

3000

4016-61TRG1

237

376

LSA52.3S5

ZOP2250PK

2250

1800

2000

1600

434

6100x2740x3120

13875

3000

4016TAG2A

237

368

LSA52.3S6

ZOP2250PK

2250

1800

2000

1600

422

6100x2740x3120

13875

3000

4016-61TRG2

237

376

LSA52.3S6

ZOP2500PK

2500

2000

2250

1800

467.6

6100x2740x3120

14900

3000

4016-61TRG3

237

376

LSA52.3L9

 


Q: if a diesel generator(say of negligible mass) is used to power an electric car powered by an electirc motor how efficient will it be when compared to a car that uses an i.c engine thats uses diesel directly?
Most Efficient Diesel Generator
Q: I am wondering if you can burn home heating oil in a diesel engine, I have a diesel generator and I am curious if I ran out of diesel say in a bad storm and couldn't get to a station for more could i but some home heating oil in it and run it with out messing things up?
They answer to that would be aye. although, only temporary as you said.
Q: ANDwhat kind is it? How many times have you had to use it? How many things could you run on it? How much did you spend? Would you buy one with more power next time, or is the one you have sufficient? What types of problems have you had with running it. Do your neighbors always ask to hook up to it?
PEP BOYS HAS' EM REAL CHEAP (CHINESE) TWO WAY TO LOOK AT IT GET ONE BIG ENOUGH TO TO LIVE LIKE YOU DO NOW VERY EXPENSIVE, NO MATTER WHAT TYPE OR FUEL! IF YOU HAVE CITY WATER SEWER, GET ONE BIG ENOUGHT TO RUN YOU REFER., A SMALL WINDOW UNIT. YOU ONLY NEED TO RUN WHILE ASLEEP MAYBE A LITTLE DURING DAY. THE CITY CAN RUN THE CITY WATER PUMPS ON GENERATOR, ALTHOUGH IT MAY NOT SEEM LIKE IT, STUFF LIKE A WATER PUMP STATION ETC GET FIRST PRIORITY AFTER A STORM. THIS IS ASSUMING YOU DON'T LIVE IN NEW ORLEANS ALL OF YOUR STATE LOCAL OFFICIALS ARE MORONS, YOUR NEIGHBORS ARE WELFARE CRACK HEADS! THE SMALLER YOU CAN GET BY WITH ( REMEMBER ITS AN EMERGENCY) THE LESS; LUGGING IT AROUND, ITS SMALLER LESS FUEL - IT RUNS LONGER ON WHAT FINITE SOURCE YOU HAVE ( LIKE MAYBE A TANK OF GAS OUT OF YOUR SECOND CAR)! LET THE KIDS SLEEP ON THE FLOOR OF YOUR ROOM YEE-HAAA CAMPING!
Q: I drive a TATA Indica DLS (not turbo), I understand that it has a base diesel engine which has 55 bhp. I have heard that CNG kits are available in the market and CNG is much economic and eco friendly. Please comment if you know about it. Is it possible ? and how much will be the cost for the conversion ? What are the steps involved ?
Not completely. A diesel engine is a compression engine hence it's the compression that ignites the fuel, natural gas doesn't ignite easily under compression and therefore requires a spark for ignition. However, it's possible to mix natural gas with the intake air but reduce the diesel fuel injectors so that a small amount of diesel fuel is injected, the diesel fuel ignites under pressure and this ignites the natural gas. Basically, it can mostly run on natural gas. Such a conversion requires some way of reducing but not eliminating the diesel injected as well as mixing in the natural gas preferably in proportion to the amount of air or according to the needs of the engine somehow. As it requires changing the fuel injector programming, this is not a conversion that is easily available but kits are available. A more practical conversion for a diesel car would be a waste vegetable oil conversion though I would consider a natural gas conversion suitable for a backup power generator especially if the conversion still allows for full diesel operation when needed. Diesel keeps much longer than gasoline when stored.
Q: Does one gas power station make a lot of energy? Or would you need more than one of them? :D X
One power station will have many gas turbines and generators. This depend upon the availability of gas,power consumption in that area,pollution problems etc.
Q: I don't see why I couldn't use my car's engine as a power generator. I would only need maybe 1000 watts. The car is a 1990 Ford F350 diesel.
you cant its too big. its a waste time u are better off selling the engine in the paper to buy a power generator
Q: Hi, I'm fifteen and going to Tanzania in February on a Mission trip. I don't know what to wear, because I don't wanna wear Nike Shorts and offend people. I'm on a mission trip so I definitley wanna be representing Christ. I also need a pack list so I wont be forgetting anything. Also, what do I take money-wise? Cash, debit nfused. First time over seas. HELP! God Bless! Merry Christmas!:) -Emma
Hello okorder
Q: fuel oil operated generator (called also heavy oil) can be a dual fuel engine e.g. fuel oil w diesel backup.engine only or a generator set.generator 150~250 Kvaif engine only: 200~300 HPused in working condition
What the heck is the question?!
Q: I may soon have to relocate to a place where the electricity is infrequent but my livelihood depends on the internet. my plan is to access the internet through the telephone and run the computer on a diesel generator and also an inverter. is it possible, what precautions should i take to make this work. will this plan work.
Yes you can run a computer on a generator. I would recommend that you use a stabilizer and a ups together with it to safeguard against any fluctuation in voltage and not lose your work if at any time it fails. Wish you all the best.
Q: I planned that the factory be fully mechanised. Public power supply is very poor. I wanted to purchase diesel generators but i have been advised by a friend that solar generators are more cost effective. Is solar a good source of energy to power such a factory?
Yes, it can be fully solar. Very power comsuming factories are autonomous. If you dont find how to, if you want e-mail me and i will put you in touch with some companies. For your info, some companies not only are autonomous, they resell power while they dont use it.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords