Hot Dipped Galvanized Iron Wire For Chain Link Fence
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Packaging & Delivery
Packaging Detail: | inner with plastic film,outside with weaving bag or hessian cloth,pallet |
Delivery Detail: | 7days after the advance payment |
Specifications
Galvanized Iron wire
hot-dipped galvanized iron wire and electro galvanized wire according to the differences of processing
Galvanized Iron wire :
Type: hot-dipped galvanized iron wire and electro galvanized wire according to the differences of processing.
Sizes of hot-dipped galvanized wire: 8# to 36#(wire diameter ranging from 3.8mm to 0.19mm)
Sizes of electro galvanized wire: 8# to 38# (wire diameter ranging from 3.8mm to 0.15mm)
Applications: of galvanized wire: Communication devices, medical treatment equipment,weaving of wire mesh, making of brushes, steel rope, filter wire mesh,high pressure pipes, construction, arts and crafts, etc.
Specifications: other specifications available
Galvanized Wire | |||
Wire Gauge | SWG(mm) | BWG(mm) | Metric(mm) |
8 | 4.05 | 4.19 | 4.00 |
9 | 3.66 | 3.76 | 4.00 |
10 | 3.25 | 3.40 | 3.50 |
11 | 2.95 | 3.05 | 3.00 |
12 | 2.64 | 2.77 | 2.80 |
13 | 2.34 | 2.41 | 2.50 |
14 | 2.03 | 2.11 | 2.50 |
15 | 1.83 | 1.83 | 1.80 |
16 | 1.63 | 1.65 | 1.65 |
17 | 1.42 | 1.47 | 1.40 |
- Q: how do I wire the generator so it can spin 360 on the pole with out snapping the wires.... Thanks
- You need some ring contacts and brushes that will be touching those rings that will be spinning while the generator does to complete a circuit without twisting wires. Make sure you get the right size rings and wire for the amount of current
- Q: How to connect a 5 wire Harley LED tail light
- My tail light wires are black,, blue and red/white stripes , 2001 Road King police. , which is for brake light?
- Q: How much does it cost to install telephone wires in your household?Does it cost around $200.00 ?
- It entirely depends on how hard it is to run the wires form location to location. If you have an attic it probably won't be too bad. If you have a two story home it can get really expensive.
- Q: What exactly is 6 AWG stranded grounding wire usually used for?
- To connect parts of the electrical system that you want to stay very near Earth potential to the actual Earth. They carry lightning strike current to the Earth if the electrical system is struck. Ground wires and grounding electrodes metal stakes driven into the Earth they connect to) keep the exposed metal parts of appliances safely close to Earth potential when there is an insulation failure inside the appliance that connects those parts to the the hot side of the circuit. The ground path resistance has to be low to soak up this fault current while keeping the appliance case voltage below about 50 volts (above which you might get a serious shock) until a protective device (fuse, circuit breaker or ground fault breaker) opens the hot line. So its main purposes are lightning protection and shock prevention. -- Regards, John Popelish
- Q: I have a 1997 Dodge Neon 2DR and i did a electric door and mirror conversion but i cannt figure out the wiring... how would i go about figuring it out... can some explain or better show me how a basic lock and mirror controls are wired
- i own a repair shop,and if you,ll get a good Haynes repair manual on it,this will have the wiring diagrams in it,for doing this ,that's about the only way you can wire it up right on this job,good luck,i hope this help,s.
- Q: I am replacing a 2 wire circuit for a fan/light combo with a 3 wire fan/light combo switch. I ran a new 12/2 w/grnd to the switch box. I ran a 12/3 w/grnd to the ceiling box for the fan. I have a ceiling fan and light control switch that control light and fan separately. I can't figure out which wires go to what.
- To make that easy to understand we take fan as light and to turn on the fan you need one neutral wire one hot wire and one ground wire.Switch is a cut circuit device which will install in hot wire(simple circuit).If already it's wired you will have 4 connected wires in the light box which one of the hot wires and neutrals are directly to the light and separate from other wires,(BLACK AND WHITE) so connect them to the fan wires as same color and if you see green wire in fan connect it to the ground(COPPER). Now 3-way wiring is using 2 control for fan. 3-way switch has 3 entry 2on top and 1 in bottom (COMMON) SHOT DOWN POWER FIRST then: 1- connect main hot to first switch (TOP LEFT) 2-connect free hot wire 3/12(RED)to the (COMMON) 3- connect BLACK hot to (TOP RIGHT) 4-connect neutral to neutral and ground to ground 5-send 12/3 after connecting as above to the fan box. 6-IN other switch with another 3/12 wire connect BLACK to (TOP LEFT) 7-connect RED to (TOP RIGHT) 8-Connect WHITE to (COMMON)and by wire tape put a black sign to white wire as return HOT. 9-Send that wire to fan box . A-NOW in fan box connect RED TO RED and BLACK TO BLACK . B-connect NEUTRAL from first switch to the fan neutral wire C-connect all the ground to gather. D-connect WHITE wire from second switch to the BLACK wire of the fan and put the black tape on it to separate that from neutral wire. Before close the switches turn on power and try both switch to make sure one will turn off and another will turn on and opposite.
- Q: i need thin insulated wire like this.
- it is called enameled magnet wire. try an electronics supply house or a motor and transformer electrical supply house. you can also purchase it online. you could also just take apart an old electric fan or door bell and unwind the magnetic wire. ~the other answerers don't understand wire, enameled magnet wire has a fine enamel insulation that needs to be sanded off in order to make a connection, as the enamel electrically insulates it to prevent an obvious short, but allows the inductive fields to easily pass through. it is used in all motors and most xfmr's.
- Q: Broken dryer, 4 bladed wire, Old dryer available to me, has a 3 wire cord, can I swap the cords?
- Yes, download the owners manual, it will tell you how to the unground neutral, and use 4 wire cord, but generally you will just need to disconnect a jumper that connects the center terminal to ground, then connect the ground wire to the frame. Post the model number if you need help finding it. I am a little confused, it seems your first and second question are opposite, but doesn't matter, all dryers in North America can work with either type. The code says you have to use the 4 wire receptacle unless you only have three wires in the junction box. NEC 250.140 Frames of Ranges and Clothes Dryers Frames of electric ranges... shall be connected to the equipment grounding conductor... Exception: for existing branch-circuit installation only where an equipment grounding conductor is not present in the outlet or junction box, the frames of electric ranges...clothes dryers, and outlet or junction boxes that are part of the circuit for these appliances shall be permitted to be connected to the grounded circuit conductor... The Equipment grounding conductor is the green wire. The grounded circuit conductor is the white/neutral wire.
- Q: I have a 200 amp main breaker just below my meter, which is mounted on a pole. The neutral wire coming in is run to ground. From this box, I've run 2 cables (1/0) ~80 ft to another box with a 150 amp main breaker. This box is grounded to an 8ft ground rod. I am wondering whether this setup (no neutral wire from meter pole to building) would potentially allow a ground fault without tripping the 200 amp main. For example, if somebody dug into the line with a backhoe? Oh yeah, the cable is in a 3ft deep trench that will be covered. I have an abridged version of the NEC, but I haven't found this particular topic covered. Thanks.
- what you did should be alright
- Q: Why would I want to upgrade the wires on my airsoft gun? What does it do?
- I think it prevents the wires from overheating and melting the insulation which could lead to a short.
Send your message to us
Hot Dipped Galvanized Iron Wire For Chain Link Fence
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords