Horizontal Multistage Designed Stainless Steel Pumps

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
2000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1. Description of Horizontal Multistage Designed Stainless Steel Pumps.

  1>Horizontal multistage stamping welding impeller and diffuser,three different type of choice.

  2>Single phase motor up to 2.2kw,Class F and IP55 motor is standard.

  3>Standard supply for liquid temperature up to 70 degree centigrade,high temperature pump are available on request.

 

2. Application for the Horizontal Multistage Designed Stainless Steel Pumps. 

  1>cooling water system

  2>agriculture

  3>domestic water supply

  4>general industrial services

  5>washing

  6>enviroment protection

 

3. Performance range for Horizontal Multistage Designed Stainless Steel Pumps. 

  capacity: Q up to 32m3/h

  head H up to 110 degree centigrade

  speed: n 2900rpm or 3500rpm

  power: P up to 55kw *2

 

4. Standard material of Horizontal Multistage Designed Stainless Steel Pumps. 

  All the parts contact with liquid made of 304 stainless steel on request.The pump head and suction & discharge can be  made of cast iron on request too.

 

5. RFQ

1>Are CNBM pumps available in DIY stores?

Yes, currently, we’re available for DIY stores all over the world.

2 > Where do I have to send pumps for service?

You must send them to the CNBM PUMP Service Point or, after contacting Customer Care, to the CNBM PUMP service center in China.

3>Are your pumps acid-proofed?

To choose the right pumps for chemical applications, we do need further details on hydraulic operations as well as on the type, concentration and temperature of the liquid.



Horizontal Multistage Designed Stainless Steel Pumps

Horizontal Multistage Designed Stainless Steel Pumps




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Significance of water pump model ISO50-160
Meaning of water pump model ISO50-160: ISO- stands for international standard code (IS). 50- indicates that the inlet diameter of the pump is 50 mm (the complete model IS50-32-160 32- indicates that the outlet diameter of the pump is 32 mm). 160- represents impeller diameter.
Q:Roots pump and dry pumpRecently, the work involved in the vacuum pump, do not understand this, is a ads602 vacuum pump
Different working conditions, our company does dry claw pump alone can also achieve the vacuum of 133 PA.
Q:What are the application areas of pumps?
Water pump has different uses, different transmission liquid medium, different flow, lift range, therefore, its structure form is not the same, the material is also different, summed up, can be roughly divided into:
Q:What should I pay attention to when buying a pump?
Four, packing inspection1. with the pump supply documents shall include: product certification, specification, packing list, agricultural pumps (such as submersible pumps, centrifugal pumps, mixed flow pumps, self-priming pump etc.) should be "Three Guarantees certificate", the implementation of the production permit (such as pump submersible pump, high pressure pump, high temperature pump 5 pump) we should have a production license.2. plugging of the orifice, to withstand wind and rain invasion, and should be strong, can withstand accidental damage.3. pumps and all supplied bulk parts supplied with the pump shall have the required identification number and shall be clear.4. pairs of oil lubricated bearings, bearings tank oil should be discharged, and fixed with "need oil filling" warning signs.
Q:What are the failures and causes of the replacement of the fuel pump assembly?
Gasoline pump is the gasoline from the gasoline tank suction and the gasoline tank has a certain pressure, thereby, it overcome the resistance of the pipeline, pipeline and fuel filter into the carburetor float chamber or electronically controlled injection engine in the guide frame.
Q:What is a gear pump for?
Internal wear of oil pumpOil pump parts wear will cause leakage. The large leakage area between the floating axle sleeve and the end face of the gear is the main part of the inner leakage. This part of the leakage accounted for about 50%~70% of the total leakage. The pump efficiency of the gear pump is much lower than the input power when the gear pump is worn and leaked. All of its losses are converted to heat energy, which will lead to overheating of the oil pump. If the joint plane is pressed, the movement of the floating axle sleeve will cause a little wear and tear when the work is in use, so that the farm tools can be lifted slowly or can not be improved, so the floating axle sleeves must be replaced or repaired.
Q:How should the water pump be installed?
(8) check the suitability of the foundation and whether the size of the foundation corresponds to the size of the pump.(9) find the position of positive pump and motor, pump set and anchor bolt and the inlet and outlet flanges, to ensure that the flange torque of the pump conforms to the standard. Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition. It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
Q:Why adjust the centrifugal pump outlet valve can adjust the flow?
The centrifugal pump at a fixed speed, the head is fixed, adjust the outlet valve to adjust the diversion area
Q:Brief description of centrifugal pump on / off operation
First, the preparation before the start(1) carefully check the inlet and outlet pipe line, valve, flange and pressure gauge joint of the pump, whether the installation is safe, comply with the requirements, whether the flow is correct, whether the anchor bolt and other connecting parts are loose or not.(2) add lubricating oil to the bearing case, and the oil level is 2/3 of the gauge of the bearing box.
Q:What is the difference between the ground pump and the pump in the commercial concrete?
What you should say here is the concrete pump.Ground pump: the pump will be placed in a position on the site, the pipeline will be sent to the construction of concrete surface,

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range