1. Description of Horizontal Multistage Designed Stainless Steel Pumps.

  1>Horizontal multistage stamping welding impeller and diffuser,three different type of choice.

  2>Single phase motor up to 2.2kw,Class F and IP55 motor is standard.

  3>Standard supply for liquid temperature up to 70 degree centigrade,high temperature pump are available on request.

 

2. Application for the Horizontal Multistage Designed Stainless Steel Pumps. 

  1>cooling water system

  2>agriculture

  3>domestic water supply

  4>general industrial services

  5>washing

  6>enviroment protection

 

3. Performance range for Horizontal Multistage Designed Stainless Steel Pumps. 

  capacity: Q up to 32m3/h

  head H up to 110 degree centigrade

  speed: n 2900rpm or 3500rpm

  power: P up to 55kw *2

 

4. Standard material of Horizontal Multistage Designed Stainless Steel Pumps. 

  All the parts contact with liquid made of 304 stainless steel on request.The pump head and suction & discharge can be  made of cast iron on request too.

 

5. RFQ

1>Are CNBM pumps available in DIY stores?

Yes, currently, we’re available for DIY stores all over the world.

2 > Where do I have to send pumps for service?

You must send them to the CNBM PUMP Service Point or, after contacting Customer Care, to the CNBM PUMP service center in China.

3>Are your pumps acid-proofed?

To choose the right pumps for chemical applications, we do need further details on hydraulic operations as well as on the type, concentration and temperature of the liquid.



Horizontal Multistage Designed Stainless Steel Pumps

Horizontal Multistage Designed Stainless Steel Pumps




Q: What are the general water pump failure, how to repair?
(2) in contact with the water pump inlet of the horizontal application of reverse flow direction, fell more than 0.5% slope, connect one end of the highest import pumps, do not completely level. If the upward tilt, the intake pipe will retain air, reducing the water pipes and pumps in the vacuum, water absorption.
Q: What are the internal losses in centrifugal pumps? How did they come about?
Hydraulic loss: the loss of water by friction, eddy, impact, etc in a flow;
Q: The function of centrifugal pump
The basic structure of the centrifugal pump is composed of six parts, namely: impeller, pump body, pump shaft, bearing, sealing ring, stuffing box.1, the impeller is the core part of the centrifugal pump, it is high speed, large output, the impeller blade and play a major role in the impeller before assembly, through the static equilibrium experiment. The inside and outside surfaces of the impeller are required to be smooth, so as to reduce the friction loss of the water flow.
Q: What is the "variable" of a variable pump? Is the displacement change or the flow change? Thank you
Variable pump variable refers to the flow can be changed to distinguish from the constant flow of quantitative pumps.
Q: Why does the centrifugal pump start and close first when the outlet valve is closed?
The contact is burned out, the bond and so on the accident, therefore closes the outlet valve, starts the electric machinery, at this time the electric machinery belongs to the no-load current movement, greatly reduces the big current impact
Q: What are the main performance parameters of hydraulic pumps?
Displacement and flowDisplacement refers to the pump (or motor) every turn a week, by the size of the sealing chamber geometry variable discharge (or enter) the volume of liquid, commonly used unit is ml/r (ml / rev). Displacement can be changed as a variable pump (or variable motor), and the displacement can not be changed into a quantitative pump (or a quantitative motor).Actual flow is the amount of flow at the outlet (or inlet) when the pump (or motor) is operating. As the pump itself leaks, the actual flow is less than the theoretical flow. As the motor itself has an internal leakage, to achieve the specified speed, in order to compensate the leakage, the actual flow of input must be greater than the theoretical flow.
Q: What is the pumping property of concrete?
Under a certain pump pressure, the farther or higher the concrete can deliver, the lower the probability of clogging, the better the concrete pumping performance.
Q: Harm of air pump and pump
If the liquid is not full, this situation is generally the suction pipe or pump shell leakage, then easy to cause cavitationHit the pump for centrifugal pumps, centrifugal pump is recommended to start closed, the discharge valve closed, starting is in the state of pump
Q: Pneumatic diaphragm pump compressed air pressure is 4 kg, the discharge pressure is how big?
Have to know the ratio, pneumatic pump, if high pressure, you can have 2:1,3:1
Q: How many concrete pump tube diameter
High pressure is the outer diameter is Phi 140 Type 150 type low pressure pipeline; pipe diameter is Phi 159 pipeline, high pressure pipeline diameter is phi 168.