Home Storage All in one Battery with IP65 VPP and IOT JX Good Quanlity
- Loading Port:
- China main port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 50 pc
- Supply Capability:
- 5000 pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification
Home Storage All in one Battery with IP65 VPP and IOT JX
Model | WH-SPHA3.6H-5.12kwhWH-SPHA3.6H-10.24kWh | WH-SPHA4.6H-5.12kwhWH-SPHA4.6H-10.24kWh | WH-SPHA5.0H-5.12kwhWH-SPHA5.0H-10.24kWh | WH-SPHA6.0H-5.12kwhWH-SPHA6.0H-10.24kWh |
Absolute Max Voltage(d.c.V) | 600 | |||
MPPT Voltage Range(d.c.V) | 100-500 | |||
Max.DC Input Power(w) | 4800 | 6200 | 6650 | 8000 |
Start-up Voltage(d.c.V) | 90 | |||
Rated Operating Voltage(d.c.V) | 360 | |||
Max.Input Current(d.c.A) | 12.5/12.5 | |||
Max.inverter backfeed current to array(d.c.A) | 0 | |||
Isc PV(d.c.A) | 18 | |||
No.of MPP Trackers | 2 | |||
No.of Strings per MPP Tracker | 1 | |||
Battery Model | WH-BXB5.12 | WH-BXB10.24 | ||
Battery Capacity | 5.12kWh | 10.24kWh | ||
Nominal Battery Voltage(dc.V) | 204.8 | 409.6 | ||
Battery Voltage Range(dc.V) | 160-227.2 | 320-454.4 | ||
Max.Charge/Discharge Current(dc.A) | 25/25 | |||
Cycling times | 6500 | |||
Depth of Discharge(%) | 90 | |||
AC Input/Output | ||||
Rated output power(W) | 3600 | 4600 | 5000 | 6000 |
Rated Apparent Power to Grid(VA) | 3600 | 4600 | 5000 | 6000 |
Max.Apparent Power to Grid(VA) | 3600 | 4600 | 5000 | 6000 |
Max.Apparent Power from Grid(VA) | 7200 | 9200 | 10000 | 12000 |
Rated Voltage(ac.V) | 220/230/240 | |||
Rated Frequency(Hz) | 50/60 | |||
Rated AC Current to Grid(acA) | 15.6 | 20 | 21.7 | 26.1 |
Max.output current(ac.A) | 17.2 | 22 | 23.9 | 28.7 |
Max.Current from Grid(ac.A) | 31.2 | 40 | 43.4 | 52.2 |
Inrush current(acA) | 16 a.c.A (peak), 11.3 us (duration) | |||
Max.output fault current(ac.A) | 57 (peak), 40 (rms) | |||
AC output Maximum output overcurrent protection(ac.A) | 40 | |||
AC input power factor | -0.8~+0.8 | |||
AC output power factor | 1 (-0.8...+0.8 adjustable) | |||
THDi | <3%< td=""> | |||
EPS Output | ||||
Max.output power(W) | 3600 | 4600 | 5000 | 6000 |
Rated Apparent Power(VA) | 4320 | 5520 | 6000 | 7200 |
Max.Apparent Power(VA) | 4320 | 5520 | 6000 | 7200 |
Rated Voltage(ac.V) | 230 (±2%) | |||
Nominal Frequency(Hz) | 50/60 (±0.2%) | |||
Max.Output Current(ac.A) | 18.8 | 24 | 26.1 | 31.3 |
Inrush Current(ac.A) | 16 a.c.A (peak), 11.3 us (duration) | |||
Max.output fault current(ac.A) | 57 (peak), 40 (rms) | |||
EPS output Maximum output overcurrent protection(ac.A) | 40 | |||
Switch time(ms) | <10< td=""> | |||
THDv@Linear Load (%) | <2< td=""> | |||
Power Factor | -0.8~+0.8 | |||
Efficiency | ||||
PV Max.Efficiency(%) | 97.6 | |||
PV Europe Efficiency(%) | 97 | |||
PV Max.MPPT Efficiency(%) | 99.9 | |||
Battery Charge by PV Max.Efficiency(%) | 98 | |||
Battery Discharge Efficiency(%) | 96.7 | |||
Protection | ||||
Over/Under voltage protection | Yes | |||
DC isolation protection | Yes | |||
DC injection monitoring | Yes | |||
Residual current detection | Yes | |||
Anti-islanding protection | Yes | |||
Over load protection | Yes | |||
Battery Input reverse polarity protection | Yes | |||
PV reverse polarity protection | Yes | |||
Surge protection | Yes | |||
Over heat protection | Yes | |||
General Data | WH-BXB5.12 | WH-BXB10.24 | ||
Dimension(W/D/H)(mm) | 550 × 233 × 1125mm | 550 × 233 × 1750mm | ||
Dimension of packing(W/D/H)(mm) | 655 × 302 × 1390mm | 655 × 302 × 2085mm | ||
Net weight(kg) | 68 | |||
Gross weight(kg) | 78 | |||
Operation Temp(°) | -10~+55 | |||
Relative Humidity(%) | 0~95 | |||
Altitude(m) | ≤3000 | |||
Ingress Protection | IP65 | |||
Cooling | Natural | |||
Inverter Topology | Non-isolated | |||
Over Voltage category | Ⅲ(AC), Ⅱ(DC) | |||
Protection class | ClassⅠ | |||
Active anti-islanding method | frequency shift | |||
Human Interface | LED/APP | |||
BMS Communication Interface | RS485/CAN | |||
Meter Communication Interface | RS485 | |||
Noise Emission(dB) | <25< span=""> | |||
Stand by Power Consumption(w) | <5 | |||
Safety and Approvals | ||||
Safety | IEC62040.1:2019 IEC 62109-1&-2 IEC62619 UN38.3 IEC60730-1 EN IEC 61000-6-2:2019 EN IEC 61000-6-3:2021 | |||
Country | AS/NZS 4777.2:2020 VDE-AR-N 4105:2018-11 MEA:2015 PEA:2016 EN 50549-2:2019 EN 50549-1+Poland deviation G99/1-6:2020 G98/1-6:2021 RD1699+UNE Distribution Code VDE0126+UTE C10/11: 2021 |
Product Introduction of Home Storage All in one Battery with IP65 VPP and IOT JX
Agave-SH, a hybrid all-in-one BESS, compatible with high voltage LFP battery system, can achieve the best function to maximize clean solar power usage for your home.
Convenient: Battery pre-installed
Quiet: Less than 25dB, no noise pollution
Flexible: IP65 Inverter up to 6KW, battery capacity up to 10KWh
Adaptative: Self-power, backup, and load shifting modes
Independent: No additional modules and inverters are required
Smart: Support VPP and IOT
Application Scenario of Home Storage All in one Battery with IP65 VPP and IOT JX
Certificates:
Our company
- Q: How to determine the battery is good or bad?
- Observe the battery electrolyte is turbid, turbidity that the battery positive plate softening. Observe the bottom of the battery whether there is sediment, if the plate off the battery capacity has been inadequate. Hand hit the battery two electrode piles If you hear an empty voice that pole pile and plate break. With a thick wire short-circuit positive and negative pile observation of the battery filling holes, such as the discovery of a bubble appears that the interval has been damaged.
- Q: What are the hazards of battery over discharge?
- When the battery discharge current is large, the heat will become more obvious, there will be serious heat generated when the battery deformation, when the concentration of lead sulfate is particularly large, will form a larger crystal particles, that lead to the battery Internal irreversible sulfation.
- Q: What battery does the van use?
- The battery is mainly composed of tube positive plate, negative plate, electrolyte, separator, battery compartment, battery cover, pole, injection liquid cover and so on. The electrode of the exhaust type battery is made of lead and lead oxide, and the electrolyte is an aqueous solution of sulfuric acid. The main advantage is the voltage stability, the price is cheap; the disadvantage is lower than the energy (that is, per kilogram of battery storage power), short life and routine maintenance frequently. Old ordinary battery life of about 2 years, and the need to regularly check the height of the electrolyte and add distilled water. However, with the development of science and technology, lead-acid battery life becomes longer and maintenance is also more simple.
- Q: 80ah how much battery storage capacity?
- The size of the battery storage power refers to the battery capacity. Battery capacity is generally calculated in AH (safety). You 80Ah battery capacity is 80Ah, meaning that if you discharge current to 80A, you can put an hour.
- Q: The role of the battery?
- Battery is widely used, can be used for ups, electric cars, scooters, cars, wind energy solar systems, security, and so on.
- Q: How does the battery increase the voltage?
- Chemical energy can be converted into electrical energy device called chemical battery, generally referred to as the battery. After discharge, the internal active material can be regenerated by charging - the electrical energy stored as chemical energy; chemical energy can be converted to electrical energy again when the discharge is required. This type of battery is called a battery (Storage Battery), also known as secondary battery.
- Q: What is a maintenanceable battery?
- Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water.
- Q: Battery 200ah / 104 what does that mean?
- This should be refers to 2V200AH battery 104, power with the 220V. Lead-acid battery nominal voltage is 2V / (each or monomer), but in fact will be higher than 2V, so the actual use and charging equipment for the matching will use 104, also useful 103, also useful 108 Only.
- Q: How does battery activation work?
- Always keep the battery surface clean. Found that the surface of dust and acid, it should be timely wipe, wipe can be wiped with soda water wipes wipe again, after rinse with water.
- Q: Lead-acid battery how to maintain?
- When receiving the battery should first check whether the phenomenon of short circuit, first short circuit repair and then fill the distilled water.
Send your message to us
Home Storage All in one Battery with IP65 VPP and IOT JX Good Quanlity
- Loading Port:
- China main port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 50 pc
- Supply Capability:
- 5000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords