• Gel Battery the AcmeG Series Battery  AG12V125F System 1
  • Gel Battery the AcmeG Series Battery  AG12V125F System 2
  • Gel Battery the AcmeG Series Battery  AG12V125F System 3
  • Gel Battery the AcmeG Series Battery  AG12V125F System 4
  • Gel Battery the AcmeG Series Battery  AG12V125F System 5
Gel Battery the AcmeG Series Battery  AG12V125F

Gel Battery the AcmeG Series Battery AG12V125F

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
2000 unit
Supply Capability:
400000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Range summary

The AcmeG range front access gel batteries is designed based on  the Acme series, using the polymer gel electrolyte with real front access structure. The state-of  the-art internal and external design ensures   AcmeG the high reliability and makes the  installation quite simple and safe when  placed on a standard relay rack tray or  in a closed cabinet. AcmeG range gel battery   is designed with high energy density and    suitable for 19". 23" rack or  cabinet.











Technical features

  • Long life
     Using the polymer gel electrolyte
     4BS paste technology
     Special paste formula
     Special patented grid alloy

  • Wide operational temperature range
     Excellent charging and discharging ability  at low temperature 
     Decline the water-loss at high temperature 

  • special structure
      real front access structure makes the installation and maintenance squite simple  and safe 
      suitable for 19". 23" rack or cabinet
      The specially centralized venting system  ensures the small gas be vented our of the closed cabinet



Type:

  AG12V125F

Voltage:

  12V

Nominal Capacity:

  125Ah(C10)  125Ah(10 hours rate:)

Length:

  558mm

Width:

  125mm

Height:

  270mm

Height    with termial:

  270mm

Weight:

  46Kg

Compliant standards
Designed to be compliant with:

  • IEC 60896-2

  • BS 6290 Part 4

  • Telcordia SR-4228

  • EUROBAT GUIDE

  • UL

  • Manufactured under system ISO9001 &  ISO14001 by NARADA

Battery installation compliant with:

  • EN 50272-2 or local equivalents

Main applications

  • Telecom standby and cyclical applications

  • UPS

  • Power plant and power transfer system

  • Solar energy system

  • Emergency lighting system

Products characteristics:

  • float voltage: 2.25Vpc at 77oF(25oC) , Equalization charge voltage: 2.40Vpc at 77oF(25oC)

  • Self discharge rate: < 2% pre month at 68oF(20oC)

  • Design life: more than 12 years at  68oF(20oC)

  • Shelf life: 6 months at 68oF(20oC)

  • Recombination efficiency: >99%

  • the Pressure at which the valve opens  & reclose is Opened at 10 to 35kpa(1.45psi to 5.08psi) and

  • closed at 3 to 15 kpa (0.44psi to 2.18psi)

  • Temperature ranges: -40oC to 50oC

  • Terminal Hardware Torque:10±0.1N  m

  • Container Material: ABS (V0 optional)

FAQ

What is a Gel Cell Battery?

A gel battery design is typically a modification of the standard lead acid automotive or marine battery. A gelling agent is added to the electrolyte to reduce movement inside the battery case. Many gel batteries also use one way valves in place of open vents, this helps the normal internal gasses to recombine back into water in the battery, reducing gassing. "Gel Cell" batteries are non-spillable even if they are broken. Gel cells must be charged at a lower voltage (C/20) than flooded or AGM to prevent excess gas from damaging the cells. Fast charging them on a conventional automotive charger may be permanently damage a Gel Battery.

What is sulfation of batteries?

Sulfation is the formation or deposit of lead sulfate on the surface and in the pores of the active material of the batteries' lead plates. If the sulfation becomes excessive and forms large crystals on the plates, the battery will not operate efficiently and may not work at all. Common causes of battery sulfation are standing a long time in a discharged condition, operating at excessive temperatures, and prolonged under or over charging.

How long a battery can last?

The service design life of a battery are vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.

Do batteries self-discharge when not in use?

All batteries, regardless of their chemistry, self-discharge. The rate of self-discharge depends both on the type of battery and the storage temperature the batteries are exposed to. However, for a good estimate, Narada batteries self-discharge approximately 4% per week at 80ĄăF.


 

Q: What is the difference between a maintenance-free battery and a conventional battery?
Different materials will produce a different phenomenon: the traditional battery in the course of the use of the phenomenon of liquid reduction occurs, because the antimony on the grid will pollute the sponge on the negative plate of pure lead, weakened after the full charge of the battery Electromotive force, resulting in excessive decomposition of water, a large number of oxygen and hydrogen, respectively, from the positive and negative plates to escape, so that the electrolyte reduced. With calcium instead of antimony, you can change the fully charged battery back electromotive force, reduce the overcharge current, liquid gasification rate decreases, thereby reducing the loss of electrolyte.
Q: How to determine the battery is good or bad?
Observe the battery electrolyte is turbid, turbidity that the battery positive plate softening. Observe the bottom of the battery whether there is sediment, if the plate off the battery capacity has been inadequate. Hand hit the battery two electrode piles If you hear an empty voice that pole pile and plate break. With a thick wire short-circuit positive and negative pile observation of the battery filling holes, such as the discovery of a bubble appears that the interval has been damaged.
Q: What are the advantages of maintenance-free batteries?
The advantage of a maintenance-free battery is that the service life is twice as long as the dry battery! And in the use of the process without maintenance! The voltage is also relatively stable.
Q: How should the battery be well maintained?
Voltage check the state of the battery standard voltage should be maintained between 12.2 ~ 12.7V. If the voltage is too low should be charged, the charge should be kept small charge for a long time. Battery charging need to use a professional charger, the owner will not try to charge their own, the owner can only keep the engine running on the battery can be charged. If the battery aging should be replaced.
Q: 80ah how much battery storage capacity?
0AH storage is 80AH ah If the actual storage capacity will have to see the brand. I have seen 100AH only 24 pound. This is not even 60AH.
Q: What kind of battery is divided into?
Ordinary battery: ordinary battery plate is composed of lead and lead oxide, the electrolyte is sulfuric acid aqueous solution. Its main advantage is the voltage stability, the price is cheap.
Q: How does the battery increase the voltage?
With the same battery pack in series; if the required current is relatively small, you can use DC-DC module.
Q: Battery 200ah / 104 what does that mean?
2V battery capacity (from 200AH-3000AH have) long design, good stability, the price is also expensive; 12V battery capacity is generally the largest 250AH, design life as 2V, price economy, high current discharge better.
Q: How does battery activation work?
If the battery is charged, because the battery discharge itself, the active substance to activate, not add acid, but should be added pure water (no minerals and impurities in the water) is best steaming water, and now you Since the addition, you can use water to wash several times, and then use 1C current charge to 2.3 times. Then discharge, so repeated several times, will be better. So that you can remove the vulcanization.
Q: Lead-acid battery how to maintain?
After passing the test, cover the exhaust cutting, pay attention to restore the filler, cover the battery cover, if the cover is glued, then glue bonding.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches