High-end Horizontal Biomass Boiler--116KW

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT or LC
Min Order Qty:
-
Supply Capability:
1000 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

High-end Horizontal Biomass Boiler--116KW


This boiler is 116KW one.


 

Introduction:

The first horizontal biomass boiler in China

High-end product---Longxiao series A, B, C


Technical features:

By the great effort, we have developed the first biomass boiler without grate. There are three kinds of hot water boilers as following:

A: blue touchscreen control system, burning any biomass fuel without dark smoke.

B: colorful touchscreen control system. motor frequency control system. drain the coked fuel in the combustion procession. burning all coked biomass fuel.

C: large colorful touchscreen control system. intelligent control system, internet control system. drain the coked fuel in the combustion. burning all coked biomass fuel.

 

Characteristics:

1. Different from tradition vertical boiler, any parts of boiler could be checked and repaired. Even the fire pipes in the boiler could be replaced without boiler disassembled.

2. It adopts world leading patent combustion system. Boilers without grate will need no more grate transporting to solve coked fuel burning problem.

3. High temperature in the hearth could be controlled to make sure that temperature is enough high to do biomass pyrolysis gasification and complete combustion. With specially designed airflow spraying, tar will not be attached to the hearth after long-time combustion and pipes will not be blocked by the attached tar, it will do little effect on the boiler's efficiency after long time using, this is what users will neglect. Long-time energy saving is what matters.

4. As store is directly connected to the hearth, many biomass boilers catch fire easily. Applying anti-back fire structure and back-flow prevention device, so that only biomass fuel can be put  into hearth, high temperature airflow can't flow into bunker. We are equipped with safety fire protection device, even when the back-flow  prevention device fails, automatic monitoring feeding system will start to force high temperature into hearth. Boiler will stop working only after cleaning all the fuels.

5. Change the traditional boiler feeding way, decrease the feeding height of bunker, increase the capacity, reduce the labor strength.

6. Traditional biomass boiler only monitor output water temperature, Longxiao series adopts touchscreen control system, clients can monitor the parameters of temperature of input water, output water, smoke, fuels in bunker, combustion in hearth etc. After the change of relevant data, it will timely remind the user of maintenance, so that to allow user to get more information about running status and energy-saving data.

 

 

Product specification:  covers from 10*104Kcal~180*104Kcal this list shows parts of specifications for reference)  

 

Item

Unit

CLHS0.12

CHLS0.24

CLHS0.35

CHLS0.48

CLHS0.60

CLHS0.73

Rated head

Kcal

10*104

20*104

30*104

40*104

50*104

60*104

Rated discharge pressure

Mpa

0Normal pressu re

Rated temperature of outlet water

                                         85

Rated temperature of return water

60

Heat efficiency

%

90

Water inlet

MM

40

50

50

65

65

80

Water outlet

MM

40

50

50

65

65

80

Drain hole

MM

40

50

50

65

65

80

Vent hole

MM

40

50

50

65

65

80

electricity

KW

1.1

1.5

1.8

2.2

2.7

3.2

size

length

MM

2060

2360

2560

2790

2820

3200

width

MM

650

738

850

1010

1060

1150

height

MM

1760

1760

1760

1960

1960

1960

High-end Horizontal Biomass Boiler--116KW




 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is a native boiler?
Its shortcomings for the sliding operation of the poor adaptability, metal consumption larger.
Q:I have no hot water but my heating is fine. What is going on? It is an intermittent gas boiler, i believe.?
There is a problem with the flow-switch on your boiler. It's supposed to sense the flow of water when you turn the tap on switch the boiler on to heat the water as it passes through. Flow-switches come in different forms depending on the model of your boiler, but my bet is that you have a rubber diaphragm type, which is part of the Diverter valve. If the diaphragm becomes stretched or split, the onrushing water does not push it make the microswitch to switch the boiler from central heating to hot water mode. Usually it is possible for the engineer to replace just the rubber diaphragm instead of the whole diverter valve, which is much more expensive.
Q:What are the gas pollutants in the gas boiler room?
If it is natural gas, the flue gas composition is very simple, water + carbon dioxide, nitrogen oxides
Q:Can Boilers Blow Up In Flames (10 Points)?
If this boiler is boiling water, then it is very unlikely there will be any flames, seeing as how water is not a combustible material. If the boiler is boiling gasoline, then flames are a definite possibility.
Q:Heat Boiler leaking when it is burning?
leave the water on as it automatically fills boiler when water is to low.The pressure is probably to high,find a drain valve and let alittle water out and watch pressure gauge till it comes down some.If it leaks from a pop off valve its because the pressure is to high or the pop off valve needs replacing.
Q:I need to replace a floor-standing boiler(heating only)is there a suitable condensing boiler for an old system
you make some good points. i myself dont think i would ever retro fit a boiler. if i were to put one in today, it would be in a new home, and designed accordingly. i am fearful of old piping starting to leak. i dont know how big your house is but have you considered just switching to a forced air system? efficiency is also a concern with old piping because of the massive size of it. to do it right , it sounds like it may cost you quite a bit , no matter what you choose. at least with forced air, you would benefit all the way around. just dont know how practical it would be for you...
Q:I have a combi boiler and just purchased a power shower. I am being told I cannot run my shower off a combi?
Yes, sadly the way a combi-boiler works, it's at low pressure. And yes, it is possible to get it to work (in a fashion) by boosting the output pressure with a pump. But I don't think it's the right, and best way for you to go. If you go to a good Bath Shower place and ask advice for an electrically-operated proper (separate) shower, working off the mains pressure, -buy it, and have it installed, you'll have got the best of all worlds. The advantages of a combi-boiler, and the independence and pleasure of a good shower. But be careful to insist on seeing your shower demonstrated IN ACTION before you buy it.. Nothing worse than buying it and then having to put up with a trickle! A trickle that might be scalding, or cold!
Q:What is the cause of the boiler water alkalinity?
Should be: even row of sewage is not timely will increase the alkalinity, the sewage is too small, should be connected to the maximum should be sufficient to reduce the alkalinity.
Q:Boiler leaking from the top! Help?
Hi going off the age of the boiler I would honestly suggest you get a few q uotes from tradesmen it will save money in the long term good luck
Q:Timer on Gas Boiler..?
Technically, the switch at the top of your steps is more for emergency use than regular operation. In other words, it's not designed to be used all the time. But in theory, it can be replaced by a timer. If your boiler has mechanical controls the timer shouldn't effect it but if you have solid state controls, then an electronic timer may influence it in one way or another. Since the line to the on/off switch is probably low voltage (the control circuit), you'd have to get a timer that's driven by that voltage or run 120VAC line to drive the timer and then have it break the control circuit. But I think I would investigate first why the boiler runs so much in the first place. To have it run most of the day isn't cheap and may be remedied by insulating or tweaking a few things here or there.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range