electrical wire prices elecrical cable /2.5mm electric Cable

Ref Price:
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
500 m
Supply Capability:
50000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

Specifications

electrical wire prices elecrical cable /2.5mm electric Cable
1.Standard:BS 6004, IEC 60227
2.Manufacturer for 10 years,

electrical wire prices  elecrical cable /2.5mm electric Cable 

 

Specifications

PVC electrical Wire BV factories price 
1.stander for your country 
2.we delievely in 5~10days 
3.free sample

PVC electrical Wire BV factories price

Detailed Product Description

The rated voltage of the wire should equal to or higher than the rated voltage of the system when wires are used at AC system. 

Specification:

 

1. The rated voltage of the wire should equal to or higher than the rated voltage of the system when wires are used at AC system.

 

If the wires are used at DC system, the rated voltage of system should be lower than 1.5 times as high as rated voltage of cable and wire. 

 

The working voltage of the system could be 1.1 times as high as the rated voltage of the cable.

 

2. The long term working temperature of electric wire should be less than 70 degree. 

 

And the long term working temperature of RV-90 electric wire should be less than 90 degree.

 

And the laying temperature should be higher than 0 degree.

 

3. The curve diameter of the wire should be longer than 8 times of the diameter of the outer diameter of cable and wire, if their outer diameter is 25 mm or above.

 

If the diameter of cable and wire is above 25 mm, the curve diameter should be at least 12 times of the outer diameter of the cable and wire.

 

Type 

Name 

Laying place and requirement

Long term working temperature

60227IEC01 

05 

BV 

BLV

Copper conductor PVC insulated wire

Aluminium conductor PVC insulated wire 

Fixed laid indoors conduit etc.

70

60227IEC07 (BV-90)

Heat resistant copper conductor PVC insulated wire at 90 degree

Mainly be laid at the places of high temperature environment and can be laid indoors, conduit.

90

60227IEC08(RV-90)

Cu conductor heat     resistant PVC insulated flexible connector wire at 90 degree

Mainly used at places where heat resistance is required.

90

BVR

Copper conductor PVC insulated flexible cable

Be laying permanent place where flexible required.

70

60227IEC10 BVV

Copper conductor PVC insulated PVC sheathed round wire

                                

Fixed laid, fit for the places with high mechanical protection and moisture place, can be laid in the air or underground.

70

BLVV

Aluminium conductor PVC insulated PVC sheathed round wire

BVVB

Copper conductor PVC insulated PVC sheathed flat wire

BLVVB

Aluminium conductor PVC insulated PVC sheathed flat wire

60227IEC02(RV)

60227IEC06(RV)

Copper conductor PVC insulated flexible connector wire

Mainly used at middle and light style moving electronics, home appliances, power and lighting and the place where flexible required.

70

60227IEC42(RVB)

Copper conductor PVC insulated flat flexible connector wire

RVS

Copper conductor PVC insulated flexible twisting connector wire

60227IEC52(RVV)

60227IEC53

Copper conductor PVC insulated PVC sheathed round flexible connector wire

 

Product Photo:

electrical wire prices elecrical cable /2.5mm electric Cable

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:power supply cable question?
well in other psus if you take them apart all the different cables are all stuck into the same power out on the inside but i have never taken apart a modular corsair before so i couldn't say for sure but it wouldn't affect your 6 pins if there was any problems it would be between the hard drives and the fans not only that but between 6 fans and 2 hard drives your probably only using like 30-40watts of power through that cable which is nothing to a 750
Q:Why does the fuse in my amps power cable keep blowing?
some were in your system the power wire running the amp is hitting ,ground and blowing the fuse,or your amp is crapped out.are the fuses in the amplifier blowing too.i would hook up another power to to amplifier out in the open and see if your having the same problem.if you do its the amplifier if its all good re run another power wire.with a distribution block and go bigger with the wire size,and you can down size the wire from the distribution block to the amplifier.hope this helps.
Q:please any one tell me the formula to find the current capacity of power cables?
Hi Sherlock, You need a copy of BS 7671 The IEE Regulations. By the cable sizes mentioned you must be in the UK. The current carrying capacity of a conductor is a function of its Cross Sectional Area, Length, Method of installation, Is it grouped with other circuits, Ambient Temperature and fuse or CB type. (these are called multipliers) For larger cables the power factor of the load must also be considered. The basic formula assuming no multipliers are used is Volt Drop per ampere per metre X length of run X Design current / 1000 Volt drop is from the tables in BS 7671 Length of run is the cable length design current is the current the cable will have to carry in normal use 1000 is because Vont Drop per Amper per Metre is given in millivolts
Q:question about vid card power cables?
That's right, the power cable is in case your power supply doesn't have a 6-pin power connector. A 300W power supply for a 3850 is cutting it a bit close, but you'll probably get away with it if the rest of your machine is typical. (Typical machines with a 3850 are just under 200W peak. See link.)
Q:Connecting jumper cables to power inverter cables (mini jumper cables)?
Mini Jumper Cables
Q:When installing an amplifier in your car, can the power cable cause interference with any speaker wires?
I have my power wire and speaker wires touching each other under my carpet. no interference at all. I'll say that it may be possible, I have just never experienced it. So I would say that it won't interfere with your speaker wires. Actually I have my power wire, all speaker wires, and the Remote wire right next to each other. no problems at all.
Q:How to install gps power cable to 2007 4runner?
As you say, take it so it is professionally done. Working on cars is very complex and requires an expert. Always best to seek a professional. Also always it is require to capitalize the acronyms of titles. Please capitalize GPS 100% of the time.
Q:Computer is dead there's no power it won't turn on there's just a constant buzzing noise when the power cable is plugged in?
well, the power supply may be dead. take it to a technician
Q:emachine power cable not making connection?
try another power lead, check all your connections, having failed that buy another power supply, work with cheapest options 1st
Q:Use laptop without power cable?
Sounds like you just have to buy a new cable.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range