• Centrifugal Water Pump with Diesel Engine for Pump Station System 1
  • Centrifugal Water Pump with Diesel Engine for Pump Station System 2
  • Centrifugal Water Pump with Diesel Engine for Pump Station System 3
Centrifugal Water Pump with Diesel Engine for Pump Station

Centrifugal Water Pump with Diesel Engine for Pump Station

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

                       Centrifugal Water Pump with Diesel Engine for Pump Station

1.Structure of  Water Pump with Diesel Engine Description

Fire Fighting Water Pump casing is axially split, which permits removal of the complete rotor without moving either piping or motor. Pumps generating high heads have double volutes to reduce radial forces. Replaceable wear rings protect the casing at the impeller running clearances. Flange drilled to ISO, DIN, BS or ANSI.The close double suction impeller gives practically zero axial forces. Each impeller is statically and dynamically balanced according to NFPA 20 STANDARD .Vertical or horizontal, soft packing or mechanical seal, grease or oil lubrication bearing on request. NFPA 20 standard pump is available.

 

2.Main Features of the Water Pump with Diesel Engine

•Diesel pump unit: diesel engine, water pump, cooling fan, cooling water tank, steel structure base (including fuel tank 80-120L), battery, connecting wires, exhaust muffler, control panel. 
•Standard design is the pump group, the fuel tank, control panel, battery composite type. 
•Can be designed according to customer requirement pump group, the fuel tank, control panel, battery, outdoor rainproof cabinet composite outdoor type. 
•Can be designed according to customer requirement trailer (four or two wheels) moveable type. 

3.Water Pump with Diesel Engine  images

Centrifugal Water Pump with Diesel Engine for Pump Station

4.Water Pump with Diesel Engine Specification

 

Pump TypeSplit Casing Pump
Casing MaterialHT200
ImpellerSS304,SS316,Copper,HT200
Pump SealingPacking seal,Mechanical seal
Capacity Range126m3/h~8520m3/h
Head Range8m~140m
Inlet/Outlet diameter6"(150mm)~32"(800mm)
Rotary Speed1450rmp/2950rpm/585rpm/730rpm/970rpm
NPSH(r)2.5m~7.5m
N.weight165kgs~2550kgs
Pump Parts

Casing,Pump cover,Impeller,Shaft, Double suction sealing ring

Shaft sleeve,Bearing etc

Certificate

ISO9001:2008,CE,TUV

 

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Q:If the suction pump does not have enough suction range, you need to add a vacuum pump to increase the suction stroke. How do you install the suction pipe of the vacuum pump? Water pump impeller is not closed, it is normal that the vacuum pump is unable to pump suction pipe to a vacuum, is it because the water pump outlet pipe connected to the role of the check valve? But the water pump, outlet pipe, check valve sealing performance can achieve the function of non leakage?
The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve.
Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Such as a large pressure of about 10m or about 0.1MPa} because the most unfavorable point fire hydrant requires more than 0.07MPa (7m) and 0.5MPa (50m) is not greater than the pressure, so unless the pump is located in the 50m Valley is still lower than the garage, or add to the valve (or the use of fire hydrant decompression) otherwise, it is 120m lift pump
Q:What is a solution pump?
Principle and structure features of canned motor pumpThe ordinary centrifugal pump is driven by coupling the pump impeller shaft is connected with the motor shaft, the impeller and the motor rotates while working and shielding pump is a kind of non seal pumps, pump and motor is sealed in a medium filled by pumping the pressure vessel, the pressure vessel only static seal and, by a group of wires to provide a rotating magnetic field and drive the rotor. This structure eliminated the traditional centrifugal pump with a rotary shaft sealing device, it can do no leakage.The pump and motor pump together, motor rotor and pump impeller fixed on the same shaft, use of shielding the rotor and the stator of the motor rotor separated in the medium, its power is transferred to the rotor through the stator magnetic field.
Q:What is the cause of the damage of pump bearings?
First of all, know your pump model, and what is the bad bearing, in order to accurately judge for you. Because in addition to some common reasons, the structure of different pumps, bearing damage caused by the reasons are different. Otherwise it is fraught with itching shoes.
Q:Why should I pump the pump before starting the centrifugal pump?
Only centrifugal water can be pumped out of the centrifugal blade to generate negative energy at the entrance. There is no water diversion. Only the negative pressure produced by the air is too low to absorb the well water.Water pump has been pumped, centrifugal pump or can not start normally, mostly because of the water pipes and air
Q:What are the starting and stopping procedures for centrifugal pumps?
The use of centrifugal pump can be divided into three steps, namely, start, run, stop.Start: you should do the following preparation before starting:(1) check the water pump equipment in good condition.(2) the bearings are filled with oil, the oil level is normal, and the oil quality is qualified(3) all the inlet valves of the centrifugal pump are opened.(4) pump water injection or vacuum pump diversion (except for flow), open the vent valve exhaust.(5) check the leakage of shaft seal. It is advisable to fill the seal with a little drop of water.(6) the motor rotates in the right direction.
Q:What's the pump? Where can I use it?
Pump can usually be divided into three types of displacement pumps, power pumps and other types of pumps according to the principle of operation. In addition to classification according to the working principle, it can be classified and named according to other methods.
Q:Why should the pump be closed when the centrifugal pump is started?
Centrifugal pump has an important characteristic: when the pressure (head) is very low, the flow will be great, which can be seen from the characteristics of the pump curve. While the pump power is directly proportional to the flow rate, pump start, no pressure in the pipeline, caused by the pump flow, high power pump, and the pump motor, the rotating part from rest to high-speed operation, need a lot of acceleration, it will cause a great starting current
Q:What is the difference between an air pump and a water pump?
Pump performance of technical parameters are flow, suction, lift, shaft power, water power, efficiency, etc.; according to the different principles of work can be divided into volume pumps, vane pumps and other types. Displacement pump is to use its studio volume changes to transfer energy; vane pump is to use the rotating blade and water interaction to transfer energy, there are centrifugal pumps, axial flow pumps and mixed flow pumps and other types.
Q:What is a vacuum pump for?
You are not confused by different names. It is mainly used in folding machines, paper cutting machines and water treatment aeration

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords