• Clean Water Centrifugal Water Pump for High Flow Rate System 1
  • Clean Water Centrifugal Water Pump for High Flow Rate System 2
  • Clean Water Centrifugal Water Pump for High Flow Rate System 3
Clean Water Centrifugal Water Pump for High Flow Rate

Clean Water Centrifugal Water Pump for High Flow Rate

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1.Specifications of Water Centrifugal Pump for High Flow Rate

Horizontal single-stage split casing water pump

High efficiency

Easy maintenance

OEM/ODM

Good quality and service

2.Main features of Water Centrifugal Pump for High Flow Rate

  • High quality centrifugal pump apply to industrial application.

  • Apply to power plant circulation.

  • Apply to water treatment.

  • Apply to agricultural irrigation.

  • Apply to flood control, hydraulic projects. 

3.Specification of Water Centrifugal Pump for High Flow Rate

Item

Water Pump

Impeller Water Pump

High Flow Rate Water Pump

Model

SLOW

Material

Cast iron

Color

Blue

Mode

Horizontal

Theory

Centrifugal Pump

Structure

Single-stage Pump

Usage

Water

Power

Electric

Standard or Nonstandard

Standard

Fuel

Diesel

Pressure

Low Pressure

Application

Horizontal Centrifugal Pump

Intlet Diameter

150-1200mm

Capacity

112-6460m3/h

Head

10-140m

Rotation Speed

970-2950r/min

Power

22-850kW

Standard

JB/T9088-99

Certificate

ISO9001

Feature

High efficiency,Easy maintenance 

 4.FAQ

 What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

 Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

 What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we will

recommend relevant product for reference.

Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
Q: The function of centrifugal pump
The basic structure of the centrifugal pump is composed of six parts, namely: impeller, pump body, pump shaft, bearing, sealing ring, stuffing box.1, the impeller is the core part of the centrifugal pump, it is high speed, large output, the impeller blade and play a major role in the impeller before assembly, through the static equilibrium experiment. The inside and outside surfaces of the impeller are required to be smooth, so as to reduce the friction loss of the water flow.
Q: How to select metering pump head?
When it comes to metering pump heads, the usual problem is when they measure acid, chlorine, fluoride, and hydrogen peroxide. Due to the difference in concentration and operating temperature, it is difficult to determine the specific pump head material.
Q: Why can't the inlet of centrifugal pump be negative pressure?
Can be negative pressure ah, the negative pressure here refers to the pressure is less than the atmospheric pressure, but the pressure can not be too low, to prevent water vapor below the saturated vapor pressure, so that water vaporization, cavitation phenomenon, the centrifugal pump will be considered.
Q: How many kinds of pumps are available and the operating principles of various pumps?
There are many kinds of pumps. There are different classifications according to different standards. If classified according to the principle of work, can be broadly divided into the following four categories:1, vane pumps: centrifugal pumps, axial pumps, mixed flow pumps, vortex pumps, etc.;2, displacement pumps: piston pumps, piston pumps, diaphragm pumps and so on;3, power rotary pump: screw pump, gear pump, etc.;4 、 special function: jet pump, water hammer pump, magnetic drive pump, etc.;
Q: How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
The unit of displacement is the milliliter. How many milliliters does the pump rotate per circle? The displacement is the pump, the individual,The unit of flow is generally a liter, a figure added to the displacement of the pump over a period of time,
Q: What is a positive displacement pump? He Weizheng displacement?
Includes a pump housing (10), a pump chamber (24), the pump chamber has an entrance channel (21) and an outlet check valve (17) export control channel (28), a displacement member (13), the definition of the pump cavity in a direction of movement in (24) and in a stroke section in the pump cavity (S) in reciprocating motion
Q: Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
Four) release bolus dosage method can use automatic release and manual release two ways, the key is to alarm after the infusion must be stopped(five) any kind of pill dose release are not restricted to replace the pill. The total dose limit for in pipe blockage after pill agglomeration process will remove blocking accident, this time will be the rapid infusion of pill dose concentration into the patient's blood, if the total dose pill does not get test and limit, rapid infusion of this accident it may have unimaginable consequences.(six) supplies open type infusion pump overflow on the domestic market for pill characteristic parameters of consumables simply without testing and limitation. Therefore, the risk of accidental pill has become one of the residual risk of open type infusion pump supplies the most deadly.
Q: The working principle of magnetic pump
Working principle of magnetic pumpN of the magnet (n is even) arranged according to the laws in the magnetic clutch assembly inside and outside the magnetic rotor, the magnet part consisting of magnetic coupling system. When the inside and outside the two poles in different relative displacements, two poles between the angle phi = 0, the lowest energy magnetic system; when rotates to the relative displacement is two poles, pole angle between phi = 2 pi /n, the magnetic system of magnetic energy. Remove the external force, due to the magnetic system of magnetic poles repel each other, magnetic magnet will return to the lowest energy state. So magnets in motion, driven by the magnetic rotor.
Q: What's the difference between a concrete pump and a concrete pump truck?
Concrete pump is a pumping machine used in the field, while the concrete pump truck is a truck mounted pump.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords