• Centrifugal Water Pump with Diesel Engine for Agriculture System 1
  • Centrifugal Water Pump with Diesel Engine for Agriculture System 2
  • Centrifugal Water Pump with Diesel Engine for Agriculture System 3
Centrifugal Water Pump with Diesel Engine for Agriculture

Centrifugal Water Pump with Diesel Engine for Agriculture

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

                       Centrifugal Water Pump with Diesel Engine for Agricuture

1.Structure of  Centrifugal Water Pump with Diesel Engine Description

Fire Fighting Water Pump casing is axially split, which permits removal of the complete rotor without moving either piping or motor. Pumps generating high heads have double volutes to reduce radial forces. Replaceable wear rings protect the casing at the impeller running clearances. Flange drilled to ISO, DIN, BS or ANSI.The close double suction impeller gives practically zero axial forces. Each impeller is statically and dynamically balanced according to NFPA 20 STANDARD .Vertical or horizontal, soft packing or mechanical seal, grease or oil lubrication bearing on request. NFPA 20 standard pump is available.

 

2.Main Features of the Centrifugal Water Pump with Diesel Engine

•Diesel pump unit: diesel engine, water pump, cooling fan, cooling water tank, steel structure base (including fuel tank 80-120L), battery, connecting wires, exhaust muffler, control panel. 
•Standard design is the pump group, the fuel tank, control panel, battery composite type. 
•Can be designed according to customer requirement pump group, the fuel tank, control panel, battery, outdoor rainproof cabinet composite outdoor type. 
•Can be designed according to customer requirement trailer (four or two wheels) moveable type. 

3.Centrifugal Water Pump with Diesel Engine  images

Centrifugal Water Pump with Diesel Engine for Agriculture

4.Centrifugal Water Pump with Diesel Engine Specification

 

Pump TypeSplit Casing Pump
Casing MaterialHT200
ImpellerSS304,SS316,Copper,HT200
Pump SealingPacking seal,Mechanical seal
Capacity Range126m3/h~8520m3/h
Head Range8m~140m
Inlet/Outlet diameter6"(150mm)~32"(800mm)
Rotary Speed1450rmp/2950rpm/585rpm/730rpm/970rpm
NPSH(r)2.5m~7.5m
N.weight165kgs~2550kgs
Pump Parts

Casing,Pump cover,Impeller,Shaft, Double suction sealing ring

Shaft sleeve,Bearing etc

Certificate

ISO9001:2008,CE,TUV

 

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Q:Advantages and disadvantages of centrifugal pumps?
The centrifugal pump has no valve, so it is suitable for conveying suspended liquid, and the special design can also transport large solid suspensionThe pump can be made of chemical resistant material, which is suitable for conveying corrosive solution.The utility model has the advantages of simple structure, few parts, little failures, durability, low maintenance cost, convenient management and reliable work.The output can be adjusted even by the discharge valve fully closed, there is no danger of infinite rising pressure head.The liquid is transferred to a large quantity. And the pressure head does not require large, most suitable for centrifugal pump.
Q:What is the nominal pressure of the hydraulic pump and hydraulic motor?
Rated flow refers to the flow under the rated speed and rated pressure input to the motor.Due to leakage loss, the actual flow of the input motor must be greater than its theoretical flow. Actual flow of motor (i.e. inlet flow) leakage flow = theoretical flow of the motor.
Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
Q:How is the pump level of submersible sewage pump determined?
Pump water level must be higher than the water pump top, so that the motor running in the lower water temperature cooling environment, otherwise long-term operation will burn the machine
Q:Please give me professionals to calculate, the cylinder bore is 100 and the rate of 20m/s, the leakage can be ignored, but to the large flow pump!
1. rpmOperating speed is the actual rotation speed of a pump (or motor) at work.Rated speed is the maximum speed that can operate normally for a long time under rated pressure. If the pump exceeds the rated speed, the work will cause insufficient oil absorption, vibration and noise, the parts will suffer cavitation damage, life expectancy.Minimum steady speed is the minimum speed allowed for normal motor operation. At this speed, the motor does not appear crawling phenomenon.
Q:Water pump does not produce water, what are the reasons?
6. is the motor running in correct directions?.7. pump body failure, such as sliding off the leaves or too much gap between the mouth ring.
Q:Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
The direct connected pump impeller is directly mounted on the motor shaft, and the non direct connected pump and motor are two shafts, and the two shafts transmit torque through the coupling
Q:How accurate is the metering pump?
In addition, when the oil supply is too large or the pipeline pressure rises unexpectedly, the volume of the liquid in the hydraulic chamber can be changed, thereby affecting the stability of the flow and reducing the metering accuracy of the pump. In order to solve the problem of how to stabilize the measurement accuracy of metering pump metering pump flow, how stable, the three valve device. The so-called actual refers to the combination of three functions including compensation, discharge and safety protection device or device supporting the hydraulic chamber, according to its action principle is different, is divided into automatic compensation and forced compensation two three valve device.
Q:The suction pump has a nominal suction range of 30 metersHow deep can a well be sucked?Well, sixteen meters,
That is impossible. The suction height of the pump is caused by the centrifugal force of the vacuum. The water is sucked into the vacuum
Q:Is the flow meter in front of the pump or after the pump?
After the flowmeter is placed in the pump, it is better to add a pressure tank or a buffer tank, so that the flow meter will work better

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords