• Centrifugal Water Pump with Diesel Engine System 1
  • Centrifugal Water Pump with Diesel Engine System 2
  • Centrifugal Water Pump with Diesel Engine System 3
Centrifugal Water Pump with Diesel Engine

Centrifugal Water Pump with Diesel Engine

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
10000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

               Centrifugal Water Pump with Diesel Engine 

1.Structure of  Water Pump with Diesel Engine Description

Fire Fighting Water Pump casing is axially split, which permits removal of the complete rotor without moving either piping or motor. Pumps generating high heads have double volutes to reduce radial forces. Replaceable wear rings protect the casing at the impeller running clearances. Flange drilled to ISO, DIN, BS or ANSI.The close double suction impeller gives practically zero axial forces. Each impeller is statically and dynamically balanced according to NFPA 20 STANDARD .Vertical or horizontal, soft packing or mechanical seal, grease or oil lubrication bearing on request. NFPA 20 standard pump is available.

 

2.Main Features of the Water Pump with Diesel Engine

•Diesel pump unit: diesel engine, water pump, cooling fan, cooling water tank, steel structure base (including fuel tank 80-120L), battery, connecting wires, exhaust muffler, control panel. 
•Standard design is the pump group, the fuel tank, control panel, battery composite type. 
•Can be designed according to customer requirement pump group, the fuel tank, control panel, battery, outdoor rainproof cabinet composite outdoor type. 
•Can be designed according to customer requirement trailer (four or two wheels) moveable type. 

3.Water Pump with Diesel Engine  images

Centrifugal Water Pump with Diesel Engine

4.Water Pump with Diesel Engine Specification

 

Pump TypeSplit Casing Pump
Casing MaterialHT200
ImpellerSS304,SS316,Copper,HT200
Pump SealingPacking seal,Mechanical seal
Capacity Range126m3/h~8520m3/h
Head Range8m~140m
Inlet/Outlet diameter6"(150mm)~32"(800mm)
Rotary Speed1450rmp/2950rpm/585rpm/730rpm/970rpm
NPSH(r)2.5m~7.5m
N.weight165kgs~2550kgs
Pump Parts

Casing,Pump cover,Impeller,Shaft, Double suction sealing ring

Shaft sleeve,Bearing etc

Certificate

ISO9001:2008,CE,TUV

 

 

5.FAQ

What is your product range?

Centrifugal pump, slurry pump, gravel pump, clean water pump, sewage pump, chemical pump, single stage

pump, double suction pump, industry pump, oil pump, paper pulp pump, mud pump, self-priming pump, pipe

water pump, boiler water pump, etc.

Are you a manufacturer?

Yes, we have been in manufacturing and marketing industry centrifugal pump over 20 years.

What information should I let you know if I want to get a quotation?

Pump capacity, pump head, medium, medium temperature, pump material, quantity, if possible, please also

provide the pump model you are using now, price will be calculated as per the pump model, if not, we willrecommend relevant product for reference.

 

Q:What is the difference between centrifugal pump and self suction pump? Which is better?
In order to prevent the filling liquid into the pump shell because of gravity flow in the low groove, in the pump suction pipe at the entrance of a non-return valve (valve); if the location of the pump below the liquid level in the tank, then start without irrigation pump.Self-priming pump is a self-priming centrifugal pump, centrifugal pump is a kind of.Specific choice of a pump, depending on your specific parameters and conditions of use.
Q:What are the functions of a disposable infusion pump?
With the development of science and technology, more and more fields need to control the flow or velocity of fluid accurately. For example, the detection and analysis of micro chemical elements in chemical industry always need to control the flow accurately. In the field of health care, the flow and velocity of traditional Chinese medicine liquid must be controlled accurately.Venous transfusion is one of the most commonly used methods of clinical treatment. It is a common medication and treatment technique for nursing specialty. Clinically, appropriate infusion rate should be applied according to the drug and patient's condition. Transfusion too fast may cause poisoning, more serious can lead to edema and heart failure;
Q:Piston filling and peristaltic pump filling which precision is high?
These two pumps are used as a metering pump to use, so the accuracy is to be on a par with the peristaltic pump has more advantages than the piston pump is the largest energy fluid conveying there are particles, and the piston pump is smaller than the peristaltic pump pulse, so we need to choose according to the material characteristics you need to transport.
Q:How many kilograms of water pump are there in the automatic washing machine on the market?
Longer service life. Automatic switch water pump, car wash automatically open and stop, easy to operate, not easy to bad, repair rate is low!!!
Q:Rules for operation of centrifugal pumps
Operating rules:1, before starting to check whether the water pump foot loose, coupling shield, and motor fan blade cover is intact, in order to ensure the safety of equipment and personal safety.2. Check whether the inlet valve is open and open as fully as possible. Is the outlet valve closed, open the bleeder valve, exhaust until there is no air, and close the bleeder valve. At the end of the valve to the pipeline in the pump cavity filled with water.
Q:What is the Rhodes pump?
The ultimate vacuum of roots pump depends on the pump structure and manufacturing accuracy, and also depends on the limit vacuum of the front pump. In order to increase the limit vacuum of the pump, the roots pump can be used in series. The working principle of roots pump is similar to roots blower. As the rotor continues to rotate, the gas is pumped from the intake air to the space between the rotor and the pump housing V0, and then discharged through the exhaust port. Since the V0 space is fully enclosed after inhalation, the gas in the pump cavity does not compress and expand. But when the top of the rotor turns off the edge of the exhaust and the V0 space communicates with the exhaust side, the gas pressure at the exhaust side is higher, and a part of the gas flows back into the space V0, causing a sudden increase in the gas pressure. As the rotor continues to rotate, the gas is expelled from the pump. Roots pump in the pump cavity, there are two "8" shape of the rotor perpendicular to each other on a pair of parallel axis, by a transmission ratio of 1 of a pair of gear belt movements synchronous reverse movement of each other. In the rotor, the rotor and the pump housing between the wall to maintain a certain gap, you can achieve high speed operation.
Q:Types and differences of pumps
Depending on the flow of the fluid, they can be subdivided into the following:Classified centrifugal axial flow type mixed flow tubular flow typeThe basic principle of impeller centrifugal force generated by the high-speed rotation of the fluid energy rotary vane extrusion propulsion of the fluid increases the pressure to get the energy mix and energy principle of centrifugal and axial and centrifugalSuch as: central air conditioning centrifugal fan, central air conditioning or cold storage axial flow water pump, mixed flow water pump, domestic air conditioner, indoor fanWorking principle of pump and fanI. the working principle of centrifugal pumps and fansThe centrifugal force generated by the high-speed rotation of the impeller fluid power, namely fluid through the impeller, pressure and kinetic energy can be improved, which can be transported to the height or distance. The impeller is arranged in a spiral shell, when the impeller rotates, the fluid axial inflow, and then turn 90 degrees into the impeller and the radial outflow impeller. Continuous rotation of the impeller inlet in the form of vacuum, so that the fluid continuously by the pump suction and discharge.
Q:Metering pumps related matters
1., exports higher than imports, avoid siphonage2. the pump head and the injection valve require vertical installation3., the attached pipe can be tightened by hand, please do not use the tool; the thread does not use the raw meal belt4. the supply voltage is stable and grounded5. installation environment clean, spacious, well ventilated) 1) metering pump suction is not normal
Q:Why is the sewage pump device coupler?
The automatic coupling device but the installation of GAK type submersible sewage pump, need lifting, people may not need to unscrew the screw water, the water pump can directly improve, after repairing down along the guide rail can realize sealing pump and pipeline, water pump and normal operation. Small sewage pump can be installed freely, large sewage pumps are generally equipped with automatic coupling device, automatic installation, installation and maintenance is very convenient.
Q:What is a vacuum pump for?
Aquaculture, screen printing machine, photographic plate machine, injection molding machine, automatic feeding machine, paper transport...

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords