CDLK/CDLKF Non-selfpriming Designed Multi-stage Centrifugal Pumps

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
2000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1. Description
CDLK/CDLKF is non-self priming multi-stage centrifugal pump installed with standard motor.The motor shaft is directly connected with the pump shaft through
coupling.According to the requirement,the pump can be equipped with intelligent protector,which effectively protects pump from dry rotation,phase lack,overload etc.In order to meet the requirement of installation depth of the water tank or vessel,it is possible to install cavity body for changing length of the pump.Length for different number of stages is shown in the dimensions & weight table and the table of products supplying scope. 

 

2. Application

Electric spark 
Lathe 
Grinding machine 
Processing center 
Cooling devices 
Industrial clearing equipment 
Filtering system 

3. Performance range
Capacity: Q up to 55 m3/h 
Head: H up to 305m 
Temperature: T up to 120degreeCelsius 
Speed: N 2900/3500rpm 
Power: P up to 45kw 

4. Standard material
Stainless steel 304 or Stainless steel 316 
The pump head and suction & discharge head can be made of cast iron on request too. 

5. FAQ

1>.  Can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

2>.  Are your pumps cheaper than those of your competitors?

CNBM aims to give its customers the highest standards of quality and service and delivery times, all at a reasonable price.

3>.  How long is your warranty?

Unless otherwise expressly authorized in writing, by specifying a longer period or different conditions, CNBM states that, for a period of twelve (12) months from delivery date, all Products supplied are free from defects in materials and workmanship, and conform to the applicable specifications. Either the delivery documentation or the invoice must be provided to prove delivery date. In absence of such documents, the production date appearing on the product label may suffice.

4>Can your pumps mount Eff.1 motors

Currently, only on request though this will shortly be a CNBM standard.

5>Are your pumps protected against dry running?

No, unprotected centrifugal pumps are not generally designed for dry running. It is important to give us or your dealer as much information as possible about the system in which the pump is used. Inlet pressure, the type of liquid to be pumped, together with relative density, viscosity and temperature, for example, are required in order to allow CNBM to recommend the right pump with the right gaskets for a long operating lifetime.

6>How can I get trained on CNBM products?

Yes, we provide training courses in our factory (products, general and specific pump technology, hydraulics, and practical applications). Please consult your sales manager or get in touch with our headquarters for more information.

CDLK/CDLKF Non-selfpriming Designed Multi-stage Centrifugal Pumps

CDLK/CDLKF Non-selfpriming Designed Multi-stage Centrifugal Pumps




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Pneumatic diaphragm pump compressed air pressure is 4 kg, the discharge pressure is how big?
Generally slightly lower than 0.4MPa, Zai 0.35Mpa or so, if the outlet is blocked, the outlet pressure will equal 0.4MPa
Q:Common failure treatment of piston pump
1) overflow valve regulation is too high, overload after the pump2) the overflow valve spool is blocked, the central hole of the valve core is blocked or the overflow valve is blocked by a damping hole, and the overflow is not overflow3) pump outlet one-way valve installed or spool blocked and stuffy pump4) motor fault x091) adjust the relief valve pressure value2) repair valve boring3) overhaul check valve4) overhaul or replace the motor
Q:Is the sewage pump the same as the mud pump?
The upstream return speed of the washing fluid is required to remove the cuttings and rock powder from the drill in a timely manner from the bottom of the hole and reliably carry it to the surface. Through drilling and extraction, mud can be obtained at the bottom.
Q:What should I pay attention to when buying a pump?
There are hundreds of water pump manufacturers in China, some of the family owned private enterprises are assembled in some areas, and the quality of the products is very good and bad, which makes it difficult to choose and buy. The main points are as follows:First, according to the required flow, lift, shaft power, efficiency, the necessary cavitation margin (or suction) and the use of conditions, the initial determination of the pump type, name, select the rated value and the required parameters of the same pump.
Q:Do you have a suction pump higher than 9 meters?
This screw self-priming pump suction process can be more than ten meters or more, my family is using this
Q:Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
Four) release bolus dosage method can use automatic release and manual release two ways, the key is to alarm after the infusion must be stopped(five) any kind of pill dose release are not restricted to replace the pill. The total dose limit for in pipe blockage after pill agglomeration process will remove blocking accident, this time will be the rapid infusion of pill dose concentration into the patient's blood, if the total dose pill does not get test and limit, rapid infusion of this accident it may have unimaginable consequences.(six) supplies open type infusion pump overflow on the domestic market for pill characteristic parameters of consumables simply without testing and limitation. Therefore, the risk of accidental pill has become one of the residual risk of open type infusion pump supplies the most deadly.
Q:Water pump spoon pipe for power plantWhich hero can tell me what is the water pump spoon tube ah? And its role
By adjusting the amount of oil entering into the hydraulic coupler, the torque of the hydraulic coupler can be controlled
Q:How should the water pump be installed?
(4) before installation, make sure all pipes connected with the pump should be clean, and no solid foreign bodies which may cause damage to the pump shall be allowed.(5) apply the blind flange or other things to the suction, exhaust or open pump to ensure that no sundries enter the pump cavity during the installation.(6) check whether the pump random data is complete and complete; whether the pump surface has obvious damage. Only with complete data, no obvious damage to the pump, you can continue to install.(7) the installation of centrifugal pump with the coupling of the hand when turning slowly rotating coupling or pulley, observe the pump rotation are stable, flexible and adjustable, the rotor parts have no jamming, the pump has no debris crash, bearing the operation is normal, with elastic suitability.
Q:The main factors affecting the performance of centrifugal pumps
Revolutions required to have. It has the following meanings: 1, similar to the geometry of centrifugal pump, everywhere efficiency at the top of the similar condition; centrifugal pump 2, than the number of different, its geometry must be different than the number; the same pump, its shape is similar, but does not rule out the shape similar situation. The following factors are related to specific speed. The specific speed of centrifugal pump has nothing to do with the nature of the conveying fluid, but has a close relationship with the shape of the impeller and the performance curve of the pump. The pump with high specific speed corresponds to the highest efficiency when the flow rate is large and the head is small
Q:What does "anti pump" mean in pump operation?
The pump again is the pump, the theory is the plugging problem can be solved, but if you are against the pump after pump has been plugging serious, and pump has been unable to solve the plugging problem, finally the worst solution is a split pipe, if the situation under enormous pressure will only exacerbate the plugging

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range