• CDL/CDLF Vertical Multistage Pump System 1
CDL/CDLF Vertical Multistage Pump

CDL/CDLF Vertical Multistage Pump

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Product introduction:
CDL/CDLF is a kind of vertical non-self priming multistage centrifugal pump, which is driven by a standard electric motor .The motor output shaft directly connects with the pump shaft through a coupling. The pressure- resistant cylinder and flow passage components are fixed between pump head and in-and outlet section with tie-bar blots. The inlet and outlet are located at the pump bottom at the same plane. This kind of pump can be quiped with an intelligent protector to effectively prevent it from dry-running,oul-of-phase and overload.

Application:
CDL/CDLF is a kind of multi-functional products.it can be used to convey various medium from tap water to industrial liquid at different temperature and with different flow rate and pressure.CDL type is applicable to conveying non-corrosive liquid, while CDLF is suitable for slightly corrosive liquid.
1 .Water supply: Water filter and transport in water works, boosting of main pipeline, boosting in high-rise buildings.
2.Industrial boosting: process flow water system, cleaning system, high-pressure washing system, fire fighting system.
3.lndustrial liquid conveying: Cooling and air-conditioning system, boiler water supply and condensing system, machine-associated purpose, acids and alkali. 4.Water treatment: filtration system, reverse osmosis system, distillation system,separator, swimming pool
5.Irrigation: Farmland irrigation, spray irrigation, dripping irrigation.


Work Conditions:
Thin, clean, non-flammable and mon-explosive liquid containing no solid granules and fibres.
Liquid temperature: Normal temperature typei-15℃ -+70℃
Hot water type:+70℃ -+120℃
Ambient temperature: up to+40℃
Altitude; up to1000 m


Q: How to adjust the flow of piston pump?
The oil pan with oil liquid through the suction port and the piston cylinder; from 180 degrees to 360 degrees, the piston cylinder volume decreases, so the oil liquid in the pan with oil discharged from the outlet of the liquid. The pump works continuously as long as the drive shaft rotates.
Q: Fire pump and shower pump flow head selection, high resolution.
Selection of flow head of fire pump and spray pump:1, the volume is greater than 5000 is less than 10000, the minimum water consumption of indoor fire hydrant is 10L/s
Q: A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
According to the water quantity form fire flow water supply system fire safety in high-rise building fire hydrant pump lift is 10L/s, accurate algorithm is to say after a simple calculation with each indoor hydrant flow is two 5L/s bolt so to get the most unfavorable point for the calculation unit to calculate the minimum requirements, with the most unfavorable point suppository pressure specifications 0.07MPa, partial loss of the most unfavorable line and the line (according to the equivalent length) and loss (according to the material resistance coefficient), and finally the pump head loss of gravity difference. But we just calculate the construction elevation difference multiplied by 110% to 120% to determine the head {there is a need to know is: conversion head (m), (kg) and MPa kg 1MPa=10 kg = 100m is the vertical water column on unit area pressure conversion
Q: If the suction pump does not have enough suction range, you need to add a vacuum pump to increase the suction stroke. How do you install the suction pipe of the vacuum pump? Water pump impeller is not closed, it is normal that the vacuum pump is unable to pump suction pipe to a vacuum, is it because the water pump outlet pipe connected to the role of the check valve? But the water pump, outlet pipe, check valve sealing performance can achieve the function of non leakage?
The role of the check valve:"[the water pump impeller is not closed" refers to the pump suction pump before the water without water inlet pipe and water outlet pipe gas should be connected] is a connector, a connector, still can make the level surface, in order to prevent the water flow along the pipe, until it reaches the level of the flush, then increased check valve.
Q: What's the pump? Where can I use it?
Working principleIt transfers mechanical energy or other external energy of the prime mover to the liquid, increasing the energy of the liquid. Before the pump starts, the pump shell is filled with the liquid to be transported; after starting, the impeller is driven by the shaft to rotate at high speed, and the liquid between the blades must also rotate. Under the influence of centrifugal force, the liquid is thrown from the center of the impeller to the outer edge and obtains energy, and leaves the outer edge of the impeller at high speed to enter the volute pump shell. In the spiral case, the liquid slows down due to the gradual enlargement of the flow passage, and the part of kinetic energy is converted to static pressure, and finally flows into the exhaust pipe at higher pressure and is sent to the required place. When the liquid flows from the center of the impeller to the outer edge, a vacuum is formed at the center of the impeller. As the pressure at the upper level of the tank is greater than the pressure at the pump inlet, the liquid is continuously pressed into the impeller. Visible, as long as the impeller continues to rotate, the liquid will continue to be inhaled and discharged.
Q: What are the basic technical parameters of the pump?
The basic parameters of the pump, the basic parameters of the main performance parameters of pump are the following: first, water pump flow Q flow is the amount of liquid in the pump unit time delivery out (volume or quality). The volume of flow with Q that the unit is: m3/s, m3/h, l/s and so on. The quality of flow unit is expressed in Qm. T/h, kg/s and so on. The relationship between mass flow and volume flow is Qm= P Q density in P - liquid (kg/m3, t/m3), room temperature water P =1000kg/m3.
Q: How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
If you're allowed to spend a minute, you can do it 20 times a minute, and that is, the amount of water you sprinkle at a time (1000) is *20.1000 (ML) *20=20000 ml =20 liters, this is the flow,Here is a formula for you to see,Pump displacement * pump speed = flow,
Q: Does the reservoir water heater press the booster pump (high marks)?
In addition, the water storage electric water heater has a safety valve is O.7MPa, before buying a booster pump, you can check the water inlet valve spring weakness, see the effect of water, barely even, then use it, do not buy.
Q: What's the difference between a concrete pump and a concrete pump truck?
Concrete pump is a pumping machine used in the field, while the concrete pump truck is a truck mounted pump.
Q: What's the submersible pump?What is a submersible pump, and what about it?
Submersible pump is a pump directly on the water inside the pump, eliminating the water inlet pipe, eliminating the trouble of ordinary water, is very convenient, just a pool, pool, bucket, water tank water level is shallow to be able to work, meet your requirements of pumping drainage

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches