Overhead Insulated Cables xlpe Insulated Cable
- Loading Port:
- China main port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 m
- Supply Capability:
- 50000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Overhead Insulated Cables xlpe Insulated Cable
Specifications
1 IEC, ASTM, DIN, BS standard
2 ISO,CCC certification
3 Response within 12 hours
4 Free Sample
5 Factory direct sale
Overhead Insulated Cables
overhead wire,pe insulated wire,xlpe insulated cable wire,ASTM,CSA standards,pvc cable,pvc insulated
Usage and Application:
Application: for overhead service applications
Primarily used for overhead service applications such as street lighting,outdoor lighting,and temporary service for construction
Aerial insulation ABC cable Detailed Product Description Single core aerial cable(overhead cable) conductor: cooper or aluminium insulation:XLPE, PE, PVC Application Overhead insulated cable may be installed in the streets with dense trees close to the buildings, site of urban construction and lead to transformer. Using this cable, it is unnecessary to prune the branches, so that reduce the across and parallel distance of the cable. It is convenient to install and high mobility. It can reduce accidents of electric shock and power failure causing by circuit troubles. To guarantee supplying of electric power for industry, Single core aerial cable (overhead cable) could make sure residents safety. It is especially suitable for an old city, which has densely buildings, densely population and narrow streets. Our overhead insulated cables have formed a system, such as single core, two-core, three-core and four-core. There are conductors of aluminum, copper or aluminum conductors steel-reinforced.
Detailed Product Description
Nominal Area | Calcu- lated Area | Wires | Approx. Overall Diameter | Nominal Breaking Load | Nominal DC Resistance at 20°C | Approx. Weight | Approx. Overall Diameter | Approx. Total Weight | Packing Length | |
No. | Dia. | |||||||||
mm² | mm² | mm | mm | KN | Ohm/km | kg/km | Mm | kg/km | (M+/-5%) | |
10 | 10.02 | 7 | 1.35 | 4.1 | 4.02 | 1.8055 | 90 | 6.1 | 115 | 2000 |
16 | 15.89 | 7 | 1.70 | 5.1 | 6.37 | 1.1386 | 143 | 7.1 | 174 | 2000 |
25 | 24.25 | 7 | 2.10 | 6.3 | 9.72 | 0.7461 | 218 | 8.3 | 256 | 2000 |
35 | 34.36 | 7 | 2.50 | 7.5 | 13.77 | 0.5265 | 310 | 9.5 | 355 | 1000 |
50 | 49.48 | 7 | 3.00 | 9 | 19.84 | 0.3656 | 446 | 11.0 | 501 | 1000 |
50 | 48.35 | 19 | 1.80 | 9 | 19.38 | 0.376 | 437 | 11.0 | 490 | 1000 |
70 | 65.81 | 19 | 2.10 | 10.5 | 26.38 | 0.2762 | 596 | 12.5 | 658 | 1000 |
95 | 93.27 | 19 | 2.50 | 12.5 | 37.39 | 0.1949 | 845 | 14.5 | 920 | 1000 |
120 | 116.99 | 19 | 2.80 | 14 | 48.90 | 0.1554 | 1060 | 16.0 | 1145 | 1000 |
150 | 147.11 | 37 | 2.25 | 15.8 | 58.98 | 0.1238 | 1337 | 17.8 | 1430 | 1000 |
185 | 181.62 | 37 | 2.50 | 17.5 | 72.81 | 0.1003 | 1649 | 19.5 | 1748 | 1000 |
240 | 242.54 | 61 | 2.25 | 20.3 | 97.23 | 0.0753 | 2209 | 22.5 | 2338 | 1000 |
300 | 299.43 | 61 | 2.50 | 22.5 | 120.04 | 0.061 | 2725 | 24.7 | 2870 | 1000 |
400 | 400.14 | 61 | 2.89 | 26 | 160.42 | 0.0456 | 3640 | 28.2 | 3810 | 500 |
500 | 499.83 | 61 | 3.23 | 29.1 | 200.38 | 0.0365 | 4545 | 31.3 | 4739 | 500 |
Picture
The competitive advantage of product line:
We have passed ISO9001, OHSAS18001, ISO14001, CE, CCC certificate and have professional design team. Our products mainly export to Africa, South America, North America, Central America, South Asia
- Q:Mine isn't so I'm just wondering what it would do.
- A thick power wire that carries a lot of current or power has anEMF - electro magnetic field around it. This field can will pass into the RCA cables - the cables that carry sound from headunit to the amp. You want the RCA cables to be as 'clean' as they can be for the best sound signal and quality. This field will interfere with the RCA's, especially low quality cheap RCA's. causing interference and poor sound quality.
- Q:My cousin gave me his old xbox but hes lost the cables so i asked one of my friends for his xbox cables to see if it still works and when i tried plugging it in the power wouldn't go in the xbox my cousin has is a halo 3 limited edition which is either an arcade or hes taken the hardrive and my question is, do all xbox-es have the same Cables for power etc and if not were can i get the right power cable for this console preferably bought in the uk
- No they don't all have the same power cable. The older ones required more power, the newer ones (two different versions) brought the power down so it wouldn't over heat so much. Where to buy them? Maybe online? Maybe some used video game store might have some?
- Q:Hey guysWhen I put in my power cable, I can turn on my laptop, but as soon as I take it off, it shuts off. Why isn't it charging it ?Thanks alot in advance
- Your laptop hates you
- Q:or do I need to buy one?
- No, the PS3 is a 3 prong outlet cable, and the PS2 is 2 prong. Also the end that plugs into the console is different for both. You can use a PC power cord for the PS3 if needed, the ends are the same.
- Q:Physically, I want to know what the cable looks like around the part that plugs into the laptop. I have a kink in the cable around that point, but don't know if cutting it and soldering is an option, depending on how complicated that part of the cable is. The rest of the cable is really simple (positive and negative) but does it get complex at the end?Note: I'm only talking about the cable, not the laptop jack itself. I'm talking about the end farthest away from the brick, that plugs into the laptop. I wanna know what that looks like, and how easy it would be to repair.
- If that is what you are trying to do,. just make sure you get one of the same size. =] EDIT: hour:32 minutes: OK!!! Then there should be no problem. Just cut the cable and solder it again. ie. lets say this is the cable: END__DAMAGE HERE_____Start Cut whre its damaged and solder it. You shold get somethng ike this: END___________Start =]
- Q:trying to install new amplifier; running cable from battery through firewall to the trunk; done on several cars before; looking for advice or best practices...
- in addition to what ed said. if you drill through a firewall or bulkhead install a grommet or use a piece of rubber tubing [hose] to protect the wire. also make sure that where you drill,nothing is behind it. ruining your evaporator or heater core normally means that the dash will have to come out for repairs on most cars ,nothing cheap here.and pinching cable around a hinge or other movable part is begging for a fire. i see this sort of crap all the time and i wonder how these owners get up and down the road without hurting someone or themselves. take your time and don't cheap the job out, most cases another twenty minutes and 5.00 dollars of parts would have resulted in a solid installation instead of a burned out hulk.
- Q:YJV-0.6 / 1KV-5x16 What does it mean? What does it mean? 1KV refers to what? 5 if it means 5 core, which 5 core refers to a 16mm2 cable has 5 core?
- It does not look good, but also affect the wallpaper, wallpaper, in full swing, and then from the chain reaction, then it is worthless, it is recommended to use decorative decorations decorated, perhaps alone for more suitable wallpaper pattern or color ... that does not affect the wallpaper Can also play a decorative effect ... Thank you
- Q:Can a PoE powered cause a surge if I connect it to a Gigabit ethernet port?PoE Switch --gt; UTP cable --gt; Non-poe Gigabit Ethernet Switch
- No, the PoE switch will initiate the connection with a low voltage signal to determine if the device at the other supports PoE or not. If not, it doesn't apply a current.
- Q:where can i put my amp power cable through my bulk head in my 1999 1.8L 16 valve ford mondeo lx?
- Find the main harness going through the fire wall and follow it
- Q:Due to the large spans the signal must travel it must be amplified or reconstructed at one point, taking into consideration that everything happens underwater, where does the box that reconstructs the signal get it's power.
- we can harness the power of currents and tides to do so.(very large bouy type generators)
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Overhead Insulated Cables xlpe Insulated Cable
- Loading Port:
- China main port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 m
- Supply Capability:
- 50000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords