• Double-Suction Horizontal Split Centrifugal Pump for Pump Station System 1
  • Double-Suction Horizontal Split Centrifugal Pump for Pump Station System 2
  • Double-Suction Horizontal Split Centrifugal Pump for Pump Station System 3
Double-Suction Horizontal Split Centrifugal Pump for Pump Station

Double-Suction Horizontal Split Centrifugal Pump for Pump Station

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
100000 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

   Double-Suction Horizontal Split Centrifugal Pump for Pump Station

1.Structure of Double-Suction Horizontal Split Centrifugal Pump for Pump Station Description

The Single Stage Double Suction Water Pump is designed for pump station, The casting is axially split, which permits removal of the complete rotor whish moving either piping or motor. Pumps generating high heads have double volute to reduce radial forces. Replaceable wear ring protect the casting at the impeller running clearances. Flange drilled to ISO, DIN, BS or ANSI. The close double suction impeller gives practically zero axial forces. Each impeller is statically and dynamically balanced according to ISO 1940.The pumps have a reduced number of parts and extensive interchangeability, which leads to minimum levels of inventory for customers and faster parts delivery. Vertical installation is a standard option with the same upper and lower casing parts. It is mounted for a space-saving configuration or when apace is at a premium. Soft packing or mechanical seal, grease or oil lubricated bearing is optional. Oil lubrication is with constant level oiler.

 

2.Main Features of Double-Suction Horizontal Split Centrifugal Pump for Pump Station

Compact structure

Attractive design

High efficiency, steady performance

big capacity, medium pressure

High concentricity of components

3. Double-Suction Horizontal Split Centrifugal Pump for Pump Station Images

 

Single Stage Double Suction Split Casing Water Pump for Pump Station

Single Stage Double Suction Split Casing Water Pump for Pump Station

Single Stage Double Suction Split Casing Water Pump for Pump Station

Single Stage Double Suction Split Casing Water Pump for Pump Station

 

4. Double-Suction Horizontal Split Centrifugal Pump for Pump Station Specification

Casing

Cast Iron, Ductile Cast Iron, Cast Steel, Stainless Steel or Duplex S.S

Impeller

Cast Iron, Bronze, Duplex S.S, Stainless Steel

Shaft

C-Steel, Cr-Steel, Stainless Steel

Wearing Ring

Cast Iron, Brass, Stainless Steel

Capacity/Q

Up to 25000m3/h,

Up to 110000gpm

Head/H

Up to 280m,

Up to 800 feet

Temperature/T

Up to 200degree

Speed/n

2900/1450/980/740/580 rpm

3500/1750/1180/890/710rpm

 

5.FAQ

①What is the applications?

Besides irrigation and drainage pumping Station, the Single Stage Double Suction Split Casing Centrifugal Pump also can be used for Circulation water for air-condition, water supply for industry and building, and other waterworks.

②How to guarantee the quality of the products?

We have established the international advanced quality management system,every link from raw material to final product we have strict quality test;We resolutely put an end to unqualified products flowing into the market. At the same time, we will provide necessary follow-up service assurance. Normally, We have 1 year warranty.

③How long can we receive the product after purchase?

In the purchase of product within three working days, We will arrange the factory delivery as soon as possible. It related to the state and detailed requirement of customers.

Q:What is the working pressure of the hydraulic pump in the hydraulic transmission system?
Generally speaking, for the fixed size, not limited equipment, the pressure can be selected lower, walking machinery heavy equipment pressure should be selected higher.If the load is selected, the working pressure is as follows:Load <5kN, working pressure <0.8~1MPa;Load 5~10kN, working pressure 1.5~2MPa;Load 10~20kN, working pressure 2.5~3MPa;Load 20~30kN, working pressure 3~4MPa;Load 30~50kN, working pressure 4~5MPa;Load 50kN, working pressure =5MPa;For example, the system work pressure of various machines is as follows:Grinder 0.8~2MPaModular machine tool 3~5MPaLongmen planer 2~8MPaBroaching machine 8~10MPa agricultural machinery, small construction machinery, construction machinery, hydraulic drilling machine 10~18MPa hydraulic machine, large and medium-sized excavators, heavy machinery, lifting transportation machinery 20~32MPa.
Q:What's the word "pump"? Is that what advocates mean?RT
What is a "fan"?In recent years, the term "fan" often appears on the newspaper Web page, whether it is a team, a singer, a sports car and a toilet, all of which have their own fans
Q:Why is the flow of the pump too small will occur cavitation phenomenon?
Throttling regulation is to change the opening of the valve to change the flow of the pump, that is to say, to change the characteristic curve of the pipeline. The commonly used to regulate the flow of exports, because the entrance throttle makes reduce the inlet pressure caused by cavitation danger.
Q:How many kinds of pumps are available and the operating principles of various pumps?
There are many kinds of pumps. There are different classifications according to different standards. If classified according to the principle of work, can be broadly divided into the following four categories:1, vane pumps: centrifugal pumps, axial pumps, mixed flow pumps, vortex pumps, etc.;2, displacement pumps: piston pumps, piston pumps, diaphragm pumps and so on;3, power rotary pump: screw pump, gear pump, etc.;4 、 special function: jet pump, water hammer pump, magnetic drive pump, etc.;
Q:The distance from the pump button to the ground
Yellow warning pop-up, indicating that the fire control room has issued alarm information, fire alarm controller (commonly known as the alarm host)
Q:The difference between submersible pumps and centrifugal pumpsWhat's the difference between the two? What is applicable and what?
1. submersible pumpsA very wide range of water treatment tools. Unlike ordinary water pumps, it works underwater, while the pump works mostly on the ground.The working principle of submersible pumpBefore the pump is opened, the suction pipe and pump must be filled with liquid. Open the pump, the impeller rotating speed, which leaves the liquid together with the rotation under the action of centrifugal force, the left outside impeller injection, injection of the liquid in the pump shell gradually slow the spread of indoor speed, the pressure gradually increased, and then from the pump outlet, the outflow discharge tube. At this time, in the leaves at the center of the vacuum area of low pressure liquid was thrown to the surrounding formation there is no air and no liquid, liquid pool at the surface of the liquid under the action of atmospheric pressure, through the suction pipe into the pump, the liquid is continuously pumped up from the liquid pool is also continuously from the outflow discharge tube.Basic parameters of submersible pumpIncluding flow, lift, pump speed, matching power, rated current, efficiency, diameter and so onSubmersible pump main application and scope of applicationIncluding construction, construction, drainage, agricultural irrigation and drainage, industrial water recycling, urban and rural residents cited water supply, and even rescue, disaster relief and so on
Q:What's the difference between a concrete pump and a concrete pump truck?
Concrete pump and concrete pump truck are concrete conveying machinery, use the same, but the former need to transport and car towing need additional support pipeline, the locomotive body and arm extends freely, without pipeline, hundreds of thousands of millions of the former, the latter
Q:What is the lift off the dead center point? This is a straight mark about the water pump. What is the function and the relationship between the design head and the pump head? ThanksWhat exactly is the dead point lift? What's the function of this indicator?
Pump downstream equipment design pressure is greater than 3MPa, if it is 400 meters, the downstream equipment design pressure is greater than 4MPa
Q:How to maintain and repair the booster pump of pipeline pump?
Installation and use1. use rubber washer and bolt to connect the pump flange at both ends and the pipe flange. In order to use and maintenance convenience, in the pump inlet and outlet pipelines should be installed with a regulating valve.2. open the inlet control valve, so that water into the pump, in order to keep the cavity filled with liquid (otherwise it will damage the seal), close the outlet valve.3. turn on the power and make sure the correct turn.4. make sure the pump starts and runs after turning.5. adjust the opening of the outlet valve so that the pump runs near the design point, depending on the rated flow and lift of the pump. [for this reason, it is better to place a pressure gauge near the outlet flange). Note: this pump is strictly prohibited to run without water, so as not to damage the seal.
Q:Household automatic booster pump, how much pressure to work automatically, the water pressure and how many kilograms?
Household automatic booster pump is not started by pressure, it is induced water pump, that is boiled water faucet

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords