Quick DetailsStandard or Nonstandard:  Standard Structure:  Gate Pressure:  Medium Pressure

Power:  Manual Material:  Casting Temperature of Media:  Medium Temperature

Media:  Water Port Size:  DN40mm-DN300 Place of Origin:  China (Mainland)

Model Number:  GF4 resilient gate valves:  resilient seat flange


Packaging & DeliveryPackaging Detail: air plastic bag inside/wooden box outside

Delivery Detail: 15-60days


SpecificationsDIN3352 F4 resilient seat flange gate valves

1.size:DN40-DN300

2.medium:water

3.standard:DIN

4.certificate:ISO9001 CE


resilient gate valves

1.size:DN40-DN300

2.medium:water

3.certificate:ISO9001 CE

4.standard:DIN


available medium:water

working temperature:≤80oC


flange dimensions:DIN2501


face to face dimensions:DIN3202F4.


Q:Butterfly valve model D373F-16C, ask God answers
D butterfly valve, 3 turbo rotating, 7 pairs clip type, 3 eccentric F PTFE seal, 16 nominal pressure 1.6MPA, C valve body material, carbon steel
Q:Have an iron block, aluminum heads, solid roller lifters, Jessel rocker shafts, what should my valve clearances be cold, and hot??
Because you apparently have a built engine here rather than a factory assembly which simply has solid lifters, and the data you have is either inconclusive or conflicting then I will recommend the following procedure: Assemble them cold and adjust to Intake .010 and exhaust .020. After firing up the engine, adjust the carb, if it is so equipped, to a smooth rich idle and run it in for a couple of hours mixing idling with moderate load and a few full throttle pulls through 2nd gear to seat the rings. Bring it back into the shop good and hot and set the valve clearances at .008 intake and .016 exhaust hot. After adjusting the valves readjust the idle to 700 RPM and set the timing. initially set the timing at about 2 degrees BTDC until you hav run in the engine, If you are without clear specifications for timing use a vacuum gauge and play with it between 2 and 10 degrees BTDC with the vacuum advance disconnected and plugged, you are looking for the highest vacuum at idle as a starting point. Run it hard including lugging it in high gear at around 2500 to 3500 rpm at or near full throttle, if you are getting spark knock back it down 2 degrees at a time until it does not knock when lugged. If you get no spark knock when lugging it you might try advancing the timing 2 degrees above the vacuum indicated optimal setting but do not go beyond that point. After setting the valves and timing readjust the carburetor to the best lean idle and set to 650 to 700 rpm depending on where it feels comfortable. In the old days a lot of this was done totally by ear - hence the term engineers. Today I think most holders of that revered title do not have a clue where the term came from.
Q:How does PLC control butterfly valves?
PLC control butterfly valve, usually control pneumatic butterfly valve or electric butterfly valve.PLC control pneumatic butterfly valve, that is, PLC program control, electric control, gas control, gas control butterfly valve;PLC control electric butterfly valve, that is, PLC program control electric, electric control butterfly valve.Control requirement:All PLC output contacts must be isolated from the intermediate relay and indirectly controlled by an intermediate relay.
Q:Who was the first doctor to discover Pulmonary Valve Stenosis? Also, who was the first doctor to perform surgery for it? Please and thank you for your help.P.S. I have this condition.
1761 - Pulmonary valvar or valvular stenosis is one of the more common forms of congenital heart malformations and it has been extensively studied since the original description of pulmonary valve stenosis by John Baptist Morgagni in 1761. 1888 - Tetralogy of Fallot, first characterized by Dr.Etienne Fallot in 1888, is present in about 3000 children born each year in the United States. It is a combination of four heart abnormalities. Dodrill and his colleagues employed it with success for the open correction of a stenotic pulmonary valve in October 1952.
Q:What are the classification criteria for pneumatic butterfly valves?
Pneumatic flange butterfly valve, pneumatic flange butterfly valve, this product is made up of rubber sealed butterfly valve and carbon steel or stainless steel valve plate and valve stem. Suitable temperature is less than or equal to 80 to 120 DEG C, such as food, chemical, petroleum, electric power, textile, papermaking, water supply and drainage, gas pipes to regulate the flow and closure of the role of media.Pneumatic control valve is a valve (valve plate) around the rotating fixed axis perpendicular to the channel, which is composed of double or single acting piston (spring reset type) pneumatic actuator and butterfly valve, a rotary type high performance adjust or cut off valves, electric, pneumatic valve positioner or electromagnetic valve, air filter regulator, limit switch (valve position), can be realized on the fluid medium in the pipeline and process to adjust the proportion of the two cut off control, automatic control to achieve the parameters of the fluid flow, pressure, temperature, liquid level etc..
Q:How can one - way sealed butterfly valves and two-way sealed butterfly valves be distinguished?
The difference between one way butterfly valve and two way butterfly valve:One way hard sealing butterfly valve:The butterfly's body usually has an arrow to indicate the direction of media flow, the butterfly valve plate in front of the closed, must face the flow of media, so we should pay attention to the medium flow direction when installing a one-way valve.
Q:Butterfly valve common faults and treatment methods?
Three, summary:Only familiar with every detail of circulating water pump outlet valve and butterfly valve equipment, timely and thorough maintenance and strict debugging, to ensure the safety and reliability of equipment operation, to ensure the healthy and orderly operation of equipment.
Q:The difference between vertical and horizontal butterfly valves in municipal water supply
Function is no difference, mainly the installation conditions are not the same, vertical valve shaft in the vertical direction, the valve well on the deep, horizontal valve shaft in the horizontal direction, the valve width to be larger, and the other is no difference
Q:The difference between butterfly valve and gate valve
Its varieties and quantities are still expanding, and the development of high temperature, high pressure, large caliber, high sealing, long life, excellent regulation, as well as multi-function development of one valve. Its reliability and other performance indicators have reached a high level. Disadvantages, there is a certain resistance to the medium. Gate valves are more used in steam pipes and large diameter water supply pipelines, because of the general requirements of fluid resistance is small, the use of gate valve. Valve is hand wheel rotation, stem upward movement. Flow is not the same, the gate valve requires full open. Need a higher installation space, the valve sealing surface has a certain self sealing capacity, its spool by the media pressure closely with the valve seat sealing surface contact, to achieve tight leakage.
Q:i just finished installing a sprinkler line for my lawn and i used anti siphon valves and 4quot; sprinkler heads. it says in the manual that it has to be at least 6quot; from the highest sprinkler. i think i made a mistake. i installed it 7quot; from the highest 'sprinkler line' . will i have a problem with that regarding the operation of the anti siphon valves and the sprinkler system itself?
anti siphon valves are junk. just install regular valves and put in a backflow preventer on your mainline before all the valves, but right after the shut off vavles.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage