Rescue Tripod Automatic Falling Prevention System

1- Material of rescue tripod: Aluminum # 6061

2- Basal Apparatus: Steel Wire of 25m/Plastic handle/Reel/Autobrake

 

  •  High strength #6061 aluminium alloy with safety factor bigger than 10;   

  •  Ring protection chain on the feet of rescue tripod;   

  •  Self-lock device on winch of the rescue tripod, which ensures lock-in in any position, to make sure the safety of the sling;   

  •  Special stainless steel sling with good suppleness is taken used. The sling will not be damaged by  corrosion or lack of oil;  

  •  The length of legs are adjusted, suitable for rugged rescue situations.  

Technical Data of Rescue Tripod

 Model  RT-400/180-A
 Closed length130cm
 Extension length 228cm
 Operating Load 400kg
 Breaking Load 1200kg
 Max. Prevent breaking force 22KN/4944.94Lbs(Steel Wire Rope)
 Length scope 134-214cm
 Packing Dimension  175*23*23cm
 Weight 17.3kg

Winch with Automatic brake device

 Wire length 25m(NO. 284.01)
 Wire Diameter 5mm
 Operating load 300kg
 Breaking Load 1800kg
 Weight 13kg


Q:Hello, everyone, with each student spent 300 yuan, bought a few life jackets, not far from our village, there is a river, not far from there is a sea
After meals, drinking is not suitable for swimming. There are open wounds, skin diseases, eye diseases, not swimming. A cold, illness, malaise, or weakness should not be allowed to swim. A thunderstorm is not fit for swimming. The water temperature is too low and too cold to swim. Do not make excessive jokes with your partner when swimming. Don't go into the water, especially in the wild. The weather is too heavy and the lighting is bad. Don't swim. Don't swim or dive in unknown waters. Shallow water, many people can not dive. To swim in a lifeguard and a qualified place. To do the warm-up before launching. The water should bring the equipment, must take the goggles. Water must not panic, disorderly, in case of cramps, please remain calm, switch to drift. Usually have the opportunity in CPR training and self-help training, such as water, people drowning, not sure should not save water, one side shouted for help the use of bamboo poles, branches, ropes, clothing or floating rescue. Avoid sunburn and foot injuries while swimming on the beach or outdoors.
Q:Are there any relevant regulations on configuring emergency rescue hammers for buses?
Overall installation is in good conditionReporters randomly take the 529 Road, 821 Road, the city bus company, 753 Road, 754 Road, Beilun bus company, 101 Road, 105 Road, urban and rural bus subordinates, Gongyun bus company under the 901 Road, 906 road and east bus company under the 628 Road, 632 road.Reporters on these lines of the bus are basically equipped with a life hammer, generally placed 4, respectively fixed suspension in front and rear of the car window frame. Some also put a life hammer on the side of the driver's seat. But the reporter also saw, 628 air conditioning car, originally 4 life hammer placed position, leaving only 2, and 632 no life-saving hammer, and even no place to see.
Q:Is there a fire emergency tunnel like this?
Thirty-sixth fire engines, fire boats and fire fighting equipment, equipment and facilities shall not be used in matters relating to fire control and emergency rescue work.Article forty-eighth in violation of the provisions of this law, one of the following acts shall be warned or fined:(1) to instigate or force others to take risks in violation of fire safety regulations, and have not yet caused serious consequences;(two) bury, occupy hydrant or occupy fire prevention space, block fire control passageway, or damage and arbitrarily use, dismantle and stop using fire control facilities and devices;(three) if there is any serious fire hazard, it shall be corrected if it is notified by the public security fire control institution.If the unit has any act mentioned in the preceding paragraph, it shall be punished in accordance with the provisions of the preceding paragraph, and shall be warned or fined by the person directly in charge and other persons directly responsible for it.In the event of any act listed in the first second paragraphs, it shall be ordered to restore the original condition or compensate for the loss within the time limit; if it fails to restore the original state after the period of time, it shall be forcibly dismantled or removed, and the expenses incurred shall be borne by the illegal actor.
Q:Hotel swimming pool facilities are complete, and lifeguards do the responsibility for treatment, 1.7 meters in the 1.2 m shallow water drowning, after the successful treatment of the hotel claims medical expenses reasonable?
Let him sue, all right, don't settle.As long as you try to actively rescue duty can not bear responsibility.
Q:Look for quality issues about the rescue capsule?
Have self-contained oxygen supply system and harmful gas removal facilities. The amount of oxygen is not less than 0.5 liters / min, and ability to deal with carbon dioxide is not less than 0.5 liters / minute, people should be able to guarantee the ability to deal with carbon monoxide in 20 minutes will be the carbon monoxide concentration decreased from 0.04% to 0.0024%.
Q:Why shouldn't civil aircraft be equipped with escape facilities?
Ha ha, have also can not use ah. Civil aircraft are pressurized cabin, the air pressure on the opening door
Q:Lifesaving equipment in refuge chamber
Long term air supply: the refuge module can accommodate up to 35 people. It can provide 96 hours of life air without external energy. Rapid deployment: the use of inflatable technology, folding membrane structure of the refuge cabin can be launched rapidly in a disaster environment, thus saving valuable time. Just remove the safety pins and pull the handle, and the evacuation module will start automatically within 3 minutes.
Q:Look for quality issues about the rescue capsule
Have self-contained oxygen supply system and harmful gas removal facilities. The amount of oxygen is not less than 0.5 liters / min, and ability to deal with carbon dioxide is not less than 0.5 liters / minute, people should be able to guarantee the ability to deal with carbon monoxide in 20 minutes will be the carbon monoxide concentration decreased from 0.04% to 0.0024%.
Q:Can a life jacket for swimmingI am a ~ ~ want to go to the nearest hot HanYaZi reservoir to swim ~ are you that I can pass the lifejacket to go swimming? Ordinary life jackets can bear my weight (87KG)? Head in the water? Do anxiously come ~
Recently went to Thailand, Buji snorkeling, 25 meters deep sea swimming, whether or not swimming, will be required to wear life jackets, in addition, when we launched into the water, there will be a number of local people custody, in order to plan security
Q:Which expert provides an electronic edition of the general technical specification for "mine removable mobile rescue capsule"?
Chapter I General ProvisionsArticle 1 in order to regulate and promote the construction of underground coal mine emergency rescue system and improve the management work, according to the "State Council on Further Strengthening the safe production work notice" (Guo Fa 2010 No. 23) the spirit of the enactment of this provision.Second design, these Provisions shall apply to the coal mine emergency system construction, use, maintenance and management, and as the coal mine safety supervision department for the construction of underground coal mine emergency rescue system for use and management of the organization and implementation of management and supervision and inspection, coal mine safety supervision mechanism to carry out safety supervision work on the basis of.Third, all wells, coal mines must be in accordance with the requirements of the construction of coal mine underground emergency system, and in line with "system reliability, facilities and management in place, orderly operation" requirements.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches