Product Description


Data:

1.Flow rate (Q)3.2-550m3/h


2.lift head (H) : 20-80m


3.Suction lift: 5-6.5m


4.Rotatory speeed:1450/2900r/min(1800/3600)


5.Suction performance:1.2-3.4 min/5m


6.Shaft power:0.46-126kw


7.Motor power:0.75-132kw


8.Brass or bronze SS304 316 impeller


9.Cast iron SS304 316  pump body


PUMP name: ZX 4 inch self priming centrifugal diesel engine irrigation  pump

Summarize:

     ZX centrifugal self-priming water pump(diesel water,self-priming pump,water pump,self-priming polluted water pump,pump) are newly developed self-priming centrifugal pumps for clean water or chemicals. The pumps have the compact structure, the high energy-efficiency to operate smoothly and reliably, the long life expectancy. It is just need to check the amount of liquid in the pump for self-priming before starting pump  

1) Detailed instructions

2) Application Area

           The self-priming centrifugal pumps are widely used for applications in the chemical, dye stuffs, petroleum, pharmaceutical, brewery, paper and pulp, metallurgical and mining industries and for oil discharge of oil carrying ships, as well as for water supply and sewage drainage of municipal industrial and emergence services.

3)Industries Served

♦ Construction

♦ Industrial

♦ Municipal

♦ Agricultural

♦ Mining

♦ Dewatering

♦ Industrial Waste

♦ Sewage

♦ Oil Field

♦ Petrochemical

♦ Paper Mills

♦ Processing


4)Parameter

Model
Flow capacity
Head
(m)
Suction
lift(m)
Rotary
speed
(r/min)
Self-priming
performance
min/5m
Power
KW
(m3/h)
L/S
Shaft
power
Motor
power
25ZX3.2-20
3.2
0.9
20
6.5
2900
1.9
0.46
0.75
25ZX3.2-32
3.2
0.9
32
6.5
2900
1.8
0.8
1.1
40ZX6.3-20
6.3
1.8
20
6.5
2900
1.9
0.87
11
40ZX10-40
10
2.8
40
6.5
2900
1.5
2.7
4
50ZX15-12
15
4.2
12
6.5
2900
2.4
1.1
1.5
50ZX18-20
18
5
20
6.5
2900
1.9
1.8
2.2
50ZX12.5-32
12.5
3.5
32
6.5
2900
1.5
2.1
3
50ZX20-30
20
5.6
30
6.5
2900
1.5
2.6
4
50ZX14-35
14
3.9
35
6.5
2900
1.5
2.7
4
50ZX10-40
10
2.8
40
6.5
2900
1.5
2.7
4
50ZX12.5-50
12.5
3.5
50
6.5
2900
1.4
4.3
5.5
50ZX15-60
15
4.2
60
6.5
2900
1.3
6.2
7.5
50ZX20-75
20
5.6
75
6.5
2900
1.3
9.8
11
65ZX30-15
30
8.3
15
6.5
2900
2
1.9
3
65ZX25-32
25
6.9
32
6
2900
1.5
4.4
5.5
80ZX35-13
35
9.7
13
6
2900
3.4
1.9
3
Our Services

 Samply available: 7~10days.
Qty: 1pc, only pump head is provided.
Price: US$100~200
OEM is welcome
OEM expierence: more than 10 years.
Countries: Germany, U.S.A, Spain, Italy, United Kingdom etc
Warranty: the whole pump is guaranteed within 1 year, the pump's spare parts are guranteed for 3 months from the date of delivery.
For more information, please do not hesitate to contact me.

FAQ


The information should be including inquiry as following:
1.Pump's flow rate
2.Pump's Head (Pressure
3.Driven Mode: By electric motor or diesel engine or bare shaft etc
4.Power and rotary speed
5.Suction lift for self priming pump
6.Temperature of liquid if you can provide
Upon the receipt of the pump's parameter, we can send our quotation to you within 24 hours.

Or the condition of pump station would be provided.

♦FAQ:

1.   Q: Can I know more about your products?

       

        A: Pls view our website: www.lanco.cc.

2. Q: What’s your MAQ of this item?

        A: 1~2PCS

3. Q: What is the lead time?

        A: 10~30 days after receiving your payment,depends on pumps.

4. Q: where is your loading port?

        A: Ningbo, China port

5. Q: Are you a manufacturer or trading company

        A: We are a manufacturer specialize in water pump and other pumps more than 20 years.

For more information, please contact me.

Detailed Images








Q:A residential building with a floor height of 11 stories and a roof height of 33 meters. The height of the water tank is 37.7 meters. The basement is -3.3 meters, only set fire hydrant, fire pump only consider the indoor fire water, fire flow should be 10l/s. Now select a fire pump, concrete should be much traffic, big head, flow determine how? How to determine the head, I hope to say some more detailed, thank you, and there is to explain this question, why is the fire pump lift 120?. Thank you
Modify the part: (the design of regional common fire pump should be in accordance with the requirements of the original design, building design) contains a 55m high building, and the basement is about 6m, the pump reached in the basement height about 61m (common fire pump should be based on the highest floor of other low floor area, low ring and take in this case, relief measures) 61 levels, the most unfavorable hydrant to reach 0.07MPa (maximum allowable 0.5MPa) plus loss of lift at least about 90m more appropriate, of course can be higher to take relief measures (120 too high), the basic flow of lossless (with the same time there is only one building fire) according to the maximum amount of a building fire water pump set can be, there must be a backup with a preparation, and then select the appropriate pump manufacturer specification query.(the 20 houses on 99m are only shared with a 135m pump)
Q:What's the word "pump"? Is that what advocates mean?RT
What is a "fan"?In recent years, the term "fan" often appears on the newspaper Web page, whether it is a team, a singer, a sports car and a toilet, all of which have their own fans
Q:Why is the flow of the pump too small will occur cavitation phenomenon?
Throttling regulation is to change the opening of the valve to change the flow of the pump, that is to say, to change the characteristic curve of the pipeline. The commonly used to regulate the flow of exports, because the entrance throttle makes reduce the inlet pressure caused by cavitation danger.
Q:Why is the submersible pump tripped on an electrical switch?There is no electrical leakage protection, directly connected to the circuit breaker, and when the switch on, the circuit breaker jumpedI checked the line is good, the pump did not break down, is not the water pump?
Submersible pump cable or motor insulation is damaged.3) motor water solution
Q:What is the function of the heating pump system for the water pump design?
Will cause some of the internal friction gap disappeared, the coupling center damage. In this case, starting the pump inevitably results in vibration, friction, etc.
Q:What is the name of the day pump and ground pump? Specific introduction
People often say "day pump" actually refers to the boom pump, it also has many other name, such as pump, boom pump, concrete pump, concrete pump truck, these words are "day pump".Ground pump, in fact, refers to the pump drag pump. Therefore, to understand the difference between day pump and ground pump is to understand the difference between the boom pump and the tow pump
Q:No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
Non negative pressure variable frequency water supply means no negative pressure superposed water supply equipment. When running, it is connected directly to the water supply pipe. Always test the pressure of tap water pipe network and water supply pipe network pressure control system, when the water pressure is lower than the pressure required by the user, the frequency conversion device based on water automatically control the pump speed through the steady flow compensator of water balance, maintain a constant pressure water supply. In the multi pump system, the control system can automatically dispatch the water pump according to the water consumption. It can balance the working time of the pump and ensure the pressure of the water supply. When the water supply pressure satisfy the required pressure, the system automatically stops the pump by the external water supply pipe network directly. CJWFG-DYG non negative pressure superposed water supply system:
Q:What is the main difference between SK water ring vacuum pump and 2BV water ring vacuum pump?
The unified corrosion resistant design of bronze impeller improves the corrosion resistance of the pump, and the stainless steel material is more suitable for more severe applications;
Q:What are the basic technical parameters of the pump?
The effective power of pump and output power, with Pe said. It is the effective energy per unit time from the pump in conveying out liquid obtained in the pump. Because the lift refers to the effective energy, pump output unit of heavy liquid obtained from the pump so that the product of head and the mass flow rate and the acceleration of gravity. Is to obtain the output from the pump in unit time of liquid effective energy - efficient pump power: Pe= P gQH (W) = QH (W) - P - density of liquid pumping (kg/m3); severe gamma - pump for transporting liquid (N/m3) - Q (pump flow; m3/s; H) - pump head (m); G (m/s2). The acceleration of gravity P axle power and effective power Pe is the difference of power loss in the pump, the size of the pump efficiency to measure the efficiency of the pump. As the effective power and shaft power ratio, with ETA said. Selection of related pumps:
Q:How long does the fine stone pump need maintenance? What should I pay attention to?
nan

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords