Split case pump

Ref Price:
Loading Port:
China Main Port
Payment Terms:
Min Order Qty:
Supply Capability:

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

  • The technical parameter of type XS pump:

    Pump outlet diameter: Dn:  80~800mm

    Capacity: Q:  22~11600m³/h

    Head : H:  7~200mm
    Temperature :T:   -20°C~105°C(Type XS)
                                 -60°C~200°C(Type XS—R)
    Solid parameter:     ≤80mg/L
    Permissible pressure ≤2.5Mpa  (Type Xs)
                                 ≤4Mpa      (Type XS—R)

    Technical Advantage:

    1.       Type XS pumps work stably with less noise and vibration and can work at a lifting speed due to short support at both sides, thus they can be widely used.

    2.       The pipelines arrangement of type XS pump looks simple and beautiful due to inlet and outlet at a same center line.

    3.       The same rotor of type XS pumps can be operated at reverse direction to avoid damage to the pumps water hammer.

    4.       Unique design of type XS pumps working at high temperature using middle support to fasten the pump casing and using cooling seals oil lubrication bearing then pump suitable for working at 200℃ especially for supplying heated water to pipe net system.

    5.       Type XS pump casting parts can be vertically or horizontally mounted according to different working condition, with mechanical seals or packing seals.

    6.       Type XS pumps look beautiful with visible lines adopting industrially designing.

    If you have any special requirement, please contact us without hesitation.

  • No file download!

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Why do we need to stop the pump?
When the valve is closed, the flow of the pump is close to zero, the power of the pump is very small, which reduces the load that the motor starts to bear and has a protective effect on the motor. Therefore, the valve closed to start the pump.
Q:Attention should be paid to the use of pumps?
To carefully check whether there is a crack impeller, impeller fixed in the bearings are loose, if there are cracks and loose, hungry phenomenon should be promptly repaired, if the pump impeller above the soil should also be cleaned
Q:How much water does the water ring vacuum pump run for an hour? If there is no steam separator, does the water vaporize?
The purpose of the steam separator is to separate the gas from the liquidWater ring type vacuum pump, water, compressed gas is discharged through the exhaust port, if not it is soda water separator is discharged, can not be separated, for the recovery of gas discharged industry is obviously impossible.Soda separator is available, the key is to see the working conditions
Q:Why should the pump be closed when the centrifugal pump is started?
On the other hand, the water on the pipe of the inlet pipe of the pump is stationary before the pump is opened, such as the sudden acceleration, and the water behind it can not keep up, which will cause the pressure of the inlet to drop suddenly and vaporize the water, and the centrifugal pump will be evacuated. (because of the centrifugal pump is rotating centrifugal force generated by the pump, leaf water and steam driven (gas) quality is very light, according to F= Ma, the centrifugal force is small, the pump can not be water sent).
Q:60 type concrete pump performance?
HBT60.13.90S performance parametersParameter name unit HBT60.13.90SMaximum theoretical concrete conveying capacity m3/h 69/43Maximum pump outlet pressure Mpa 13/7
Q:Water pump spoon pipe for power plantWhich hero can tell me what is the water pump spoon tube ah? And its role
By adjusting the amount of oil entering into the hydraulic coupler, the torque of the hydraulic coupler can be controlled
Q:What is the function of the heating pump system for the water pump design?
As the feed water temperature is higher, in the case of non warm pump start, will make the pump body is subject to greater thermal impact; in addition, the flow components with the pump contact heating fast, not contact with water directly heating slowly. This expansion due to uneven speed, it will inevitably produce thermal stress, deformation of the pump body, sealing surface, the joint surface is lax and leaking phenomenon. Therefore, the warm water pump system is designed for the water pump.
Q:Fire hydrant pump button, under what circumstances do not need to install?
The installation of hydrant pump buttons depends on the type of water supply:(1) municipal water supply; (in this case, do not have to install)(2) there is a fire pump; (must be installed)
Q:Any center of the pump
Alignment methods and requirements:1, check two feeler dial gauge or flange coupling the parallelism, usually with clearance between the both ends of the side instead of difference, in the circumferential direction every 900 measure, the maximum and minimum gap gap difference (Ab) less than or equal to 0.3 mm.2, the coupling flanges outside the park up and down, left and right four position to check whether they are in the same line, C less than or equal to 0.1 mm.When looking for a positive C, it will affect (a - b), finding the right (a - b) will affect the C, to balance each other. It's easier for an unskilled comrade to find C (a - b) first, and then find a positive one. Through the adjustment of the motor at the foot of the gasket thickness (Ab) and meet the requirements of C.Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition.It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
Q:What is cavitation, centrifugal pump cavitation phenomenon how to solve?
In order to make the pump full of liquid, usually in the valve installed at the bottom of the filter screen along the suction pipe, the valve until the end against the valve, strainer prevents the solid material into the normal operation of the pump impeller damage or hinder the pump.

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range