WQ blockage-free sewage submersible pump(hereinafter as pump) is untegrative motor and pump. Which is manufactured based on absorbing domestic and foreignadvanced technology and advantages. Impeller, designed with hydraulic model and made by precision casting, has the advantages of energy-saving, anti-winding and non-clogging,etc. At the same time, the pumps have a unique effect in the carriage of solid particles and long fibers garbage. Single or dual impeller structure ensures the pump has the higher efficiency when it has bigger flow. So this king of pump is a ideal drainage pumps for industries and cities.

Application:
1. Living waste water discharging
2.Sewage system of municipal works
3.Sewage system in factory and mine corporation
4.Other transportation of none orrosive and diluted medium
5.Temporary floodwater discharging
6.Waste water discharging of public facility
7.Various waterd is chharging system

Work Conditions:
1.Capacity scope:2-1500m³h;
2.System pressure:≤0.6mpa;
3.Medium consistency:≤1.3x10³kg/m³
4.Motor insulation class:IP68;
5.Rotation:clockwise rotation viewed from motor;
6.Rated Speed:970-2900r/min;
7.Head scope: 3-45;
8.Medium temperature:-15℃-+60℃;
9.Medium PH scope:5-9;
10.Motor insulation class:E Grode;


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to maintain and repair the booster pump of pipeline pump?
Installation and use1. use rubber washer and bolt to connect the pump flange at both ends and the pipe flange. In order to use and maintenance convenience, in the pump inlet and outlet pipelines should be installed with a regulating valve.2. open the inlet control valve, so that water into the pump, in order to keep the cavity filled with liquid (otherwise it will damage the seal), close the outlet valve.3. turn on the power and make sure the correct turn.4. make sure the pump starts and runs after turning.5. adjust the opening of the outlet valve so that the pump runs near the design point, depending on the rated flow and lift of the pump. [for this reason, it is better to place a pressure gauge near the outlet flange). Note: this pump is strictly prohibited to run without water, so as not to damage the seal.
Q:Water pump outlet valve sequence
In order to prevent the generation of water hammer when the pump stops the damage to the rubber head, should be immediately set rubber head pump outlet, the gate valve and the check valve is not a very convincing reason to decide the order of habits in our hospital order rubber head, check valve, gate valve1. Check valve located in front of the pump, I do not know what the significance is too great to think of.2. The actual installation sequence shall be: soft fittings, check valves, gate valves. The pressure gauge is best installed on the water outlet of the pump, but it must be in front of the check valve.Reason: 1) the soft joint is used to reduce vibration. The connection between the pump and the piping system, of course.2) normal work, the gate valve is not operating, and the check valve is frequent action, so the probability of maintenance is larger, when the maintenance of the pump closed, the water outlet valve can be maintained without affecting the normal operation of the system.3) the pressure gauge is installed in the check valve, which can prevent the impact and damage of water hammer on the pressure gauge.
Q:Centrifugal pumps for normal operation, is it reasonable to install valves on their inlet lines?
Reasonable, no valve, how to debug, overhaulGenerally installed on imports of valves of relatively large Cv value
Q:How can the submersible pump level meter be connected?
Install liquid level controller, two position liquid level sensor, controller to buy manual, wiring according to wiring diagram.
Q:What is the relationship between the minimum suction vacuum of a pump and the required cavitation?
Suction is allowed to pump the vacuum from the distance from the inlet, which is part of the field installation.The manufacturer of cavitation allowance is closely related to the design and process of pump. Estimation formula: cavitation allowance =10.33 meters - allow suction of -0.5 meters (safety).
Q:What's the difference between non negative pressure and variable frequency water pump?
When peak water is used, the fluctuation of water pressure will be the same for customers! Because the key to the fluctuation of hydraulic pressure is the flow rate of the pump and the lift of the pump. As long as the flow of the selected pump is large enough, the tank is large enough, the lift head is suitable, and the pressure fluctuation is relatively small. And the selection of non negative pressure and frequency conversion pump group is not directly related. If the municipal tap water pressure and water sufficient (large enough diameter), the use of non negative pressure is better. If the municipal tap water pressure and water shortage, you can only use the frequency converter pump + water tank, no negative pressure can not be used.
Q:What is the minimum continuous flow of a pump?
The minimum continuous steady flow can be obtained by test and, in general, the pump supplier will indicate(2) minimum continuous heat limited flow (.API) provides minimum continuous heat limit flow, which means the minimum continuous flow that the pump can maintain and that its operation is not impaired by the temperature rise of the liquid being pumpedMinimum continuous heat limited flow can be calculatedIn the formula, the Pe amount of the fixed axis power is.KW;P pump medium density, kg / m3;
Q:Advantages and disadvantages of canned pumps
The graphite bearing lubrication medium, make the operation less noise and manual, reduce maintenance costs; in recent years, bearing material added with silicon carbide SIC, super hard, life is better than that of graphite bearing.The vertical structure can be installed on the pipeline like a valve, the installation is convenient and quick, and the motor and the impeller can be drawn out only when the utility model is used, and the pipeline is not needed to be removed.The utility model can be installed and run with a shock absorber or a damping pad, so that the pump is less noisy at running time.
Q:What is the difference between centrifugal pump and rotary vane pump?
The vane pump can be divided into centrifugal pump, mixed flow pump and axial flow pump according to the direction of liquid flow in the impeller.Centrifugal pump is a kind of vane pump, which is the most widely used.
Q:What is cavitation, centrifugal pump cavitation phenomenon how to solve?
The pump is in operation, if the over-current part of the local area (usually the impeller blade inlet somewhere later) for some reason, the absolute pressure of pumping the liquid was reduced to liquid vapor pressure temperature, liquid vaporization began in the area, produce a lot of steam, forming bubbles, when the liquid contains a lot of bubbles forward by high pressure impeller zone, high pressure liquid around the bubbles in the bubble decreases drastically and rupture. Condensation in the bubble burst at the same time, the liquid particle filled hole at a high speed, this moment has a very strong effect of water hammer, and with a high impact frequency against the metal surface, the impact stress of hundreds to thousands of atmospheric pressure, impact frequency can be up to tens of thousands of times per second, serious breakdown when the wall thickness will be.The process of cavitation in a pump is caused by the bursting of bubbles and bubbles in the water pump and the destruction of the over-current components. Water pump cavitation, in addition to the over-current components will have a destructive effect, but also noise and vibration, and lead to the performance of the pump down, seriously when the pump will be interrupted liquid, can not work properly.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range