Commercial Galvanized Steel Wire

(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .

(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .

(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.

(4) Tensile Strength Range

Size (mm)

Tensile Strength (mpa)

0.15-1.60

290-550

0.65-1.60

400-550

1.61-6.00

400-1200

(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.

(6) Packing

Size (mm)

Coil Size

Spool Packing

Big Coil Packing

ID (mm)

OD (mm)

0.15-0.26

6 inch

1-14kg/spool

0.27-0.60

8 inch

1-100kg/spool

0.61-1.60

12/14/16 inch

1-100kg/spool

250-400

400-770

1.61-6.00

14-500kg/spool

450

800

508

840


(7) Zinc Coating

Meet GB/T 15393 standard.

Size (mm)

Weight of Zinc-Coating ( g/m2 )

A

AB

B

C

D

E

F

A1

B2

0.25

30

20

18

>0.25-0.40

30

25

20

>0.40-0.50

30

20

>0.50-0.60

35

20

>0.60-0.80

120

110

40

20

>0.80-1.00

150

130

45

25

>1.00-1.20

180

150

50

25

>1.20-1.40

200

160

50

25

>1.40-1.60

220

180

50

35

30

>1.60-1.80

220

180

70

40

30

>1.80-2.20

230

200

80

50

40

>2.20-2.50

240

210

80

55

40

>2.50-3.00

250

230

90

70

45

>3.00-4.00

270

250

100

85

60

30

>4.00-5.20

290

270

110

95

70

40

>5.20-6.00

290

270

245

110

100

80

50


Q:my old light fixture had 2 white wires (from ceiling) twisted together and connected to a screw, it also had a green wire (from ceiling)connected to it with a screw.no black wires were connected to light fixture although they are 3 wires in the ceiling taped off together.how do i test for hot wire, i got a tester that lights up.i got a new light fixture that has 3 wires, 1 wht 1blk and copper.i know the copper goes with green, white with white and black with black. so i untangled the black wires, and i connected one to new light.but now my new light doesnt turn off.so i know i by passed my switch.how do i test for hot wire....where does the hot wire go?is it possible one of the white wires is my hot wire and the other white whire my neutral....so help please, im confused and frustrated
you are in a older home where there was no black wire. you that your tester ,and put one end to the gound then that the other end to the other wire one at a time to see if is hot . one will and the ohrer not. if you have a switch then trun it . and off to make sure it work those wire . some old light had pall chains to trun the light on.
Q:what wires are my speaker wires going to and coming from the factory amp and how do i hook them up please help i drive a 96' ford exploder
aamp of america has a psa interface part# BHA 5511. It works great The other way is to rewire from the psa to the radio. The psa is over the r rr wheel well (a real pain in the butt to get to)
Q:What exactly is 6 AWG stranded grounding wire usually used for?
In a nutshell: a) Verify that your service drop has the capacity for the additional load - verify this with your utility. b) If you are planning to install a 200A service in the barn, and you are planning to bury the wire, you will need to use 3-0 wire in a conduit. Use separate conductors. Check with your local electrical inspector, but I do not believe you will need to run a separate ground within the conduit for this application. The code may have changed, however. c) You will need to install a 200A fused safety-switch at the pole, and a new 200A panel in the barn. d) The barn panel will also have a 200A main disconnect breaker in it. e) You will need to install an additional ground-rod (or rods) at the barn panel. 1. DO NOT use old/used wire. 2. Consider running triplex wire overhead as it will be less expensive and equally effective. 3. Get the work inspected by an underwriter - your fire insurance will be voided if you do not. Lastly, it is not rocket science, but the codes and standards that apply are there for a reason - follow them carefully and fully and you will be fine.
Q:I don't like wiring nuts because I always feel like it's not a solid connection, like it could come out.
There are many different alternatives to wire nuts: split bolts, butt splices, push in wire connectors, terminal blocks, etc. Each has its own unique qualities with pros and cons. However, a properly installed wire nut is a very secure method for connecting wires.
Q:How do I wire this ceiling fan? There are two house wires coming from ceiling-one white, one black. There are three wires on the fan- one white, one solid black, and one black with a white stripe. There is one light switch in the room that will be operating the fan/light (the fan has a light on it). I wired the white wire to the white wire, the black wire with the white stripe to the black wire, didn't know where to wire the solid black wire to. Now only the light part of the fan works, the fan does not work at all. Where does the solid black wire go? I need both the fan and the light to work.
The black and black/white are the hot legs for the fan and the light kit.If you have separate switches on your wall then you could operate the fan and the light without having to pull the string.On my house all the switches are that way.Up in the ceiling there is an additional hot wire.It is colored red.
Q:other than soldering and using a T-tap (wire tap), what are other common ways of connecting two wires together? Also, what does the following video say at the 1 minute 10 second mark? It's a something-set that helps to attach wires.
wires can be welded or brazed (which is a little different than soldering) and mechanically attached (wire nut or screw terminal). THere are some electrically conductive pastes and adhesives. The ends of the wires can be immersed in a container of Hg (but this is getting farther away from common ways).
Q:I have a water valve that I need to connect but I don't know how to read this diagram. I'm unsure how to connect the wires to the cold and hot valve. I have four wires that need to be connected. A pair of white caps with one blue wire and one orange; and a pair of black caps with one blue wire and one yellow wire. Sorry if this sounds confusing but I have no idea how to explain it well. Thanks!
Oddly the diagram shows three valves, a hot and two cold valves. If you were needing to wire Cold Valve 1 and Cold Valve 2, the wire colors you describe are shown as one or two letters in front of the connector IDs (where BL presumably means blue, and O and Y, orange and yellow).
Q:ok got the mute wire figured out thanks to yahoo answers people..now i was wondering what the [ ILL] WIRE IS FOR ,ILLUMINATOR FOR SOMETHING?..also which wires on the speaker wires are pos and neg one is solid ,one is solid with stripe..not sure which is pos or neg thanks alot steve
first answer is correct, However, as long as you keep the solids and stripes consistent, it doesn't really matter if you hook them up negative stripe or positive stripe...just keep them all the same..
Q:does copper, bell, or speaker wire carry energy faster
No, the speed of electricity along a wire is only a bit slower than the speed of light, and the type of wire does not change that by much if any. Besides, bell and speaker wire is usually copper. Note that the size of the wire determines how much energy is transferred along the wire as opposed to dissipating it in the wire itself. Thicker wire is better. .
Q:On what actually does ampere depends, thickness of wire or number of turns of wire or what else? Electrical
Higher current requires lower resistance in order to prevent heat buildup in wires. Multi-strand wires are not suitable for higher amperage applications. Stranded wires have higher resistance and insulating air pockets, which will cause them to heat up with increased current.. possibly to the point of melting insulation and/or causing fire hazards. Some stranded core wire uses material other than copper to cut costs, which further increases resistance. Large diameter solid core copper wire is the standard solution. They offer lower resistance and better heat handling ability. The trade-off is less flexibility and lower durability in moving or reuse situations.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords