Hot dip/ Electric galvanized Double Twist Barbed Wire Fencing Real Factory (ISO)
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 m.t.
- Supply Capability:
- 5000 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Item specifice
Product Description
Barbed Wire
Material:Galvanized steel wire,stainless steel wire, PVC coated wire
Types of Barbed Wire:
Galvanized Barbed Wire
Galvanized barbed wire is used in defending of farm land, sport ground, or used together with concertina razor wire. Normally it's settled above the fence, for example chain link fence and welded fence, avoiding climbing across. Galvanized barb wire can also form a barbed wire wall with wooden sticks or iron sticks. The weaving methods are one main wire, one barbed wire; one main wire, twin barbed wire; and twin main wire, twin barbed wire.
PVC Coated Barbed Wire
Core of PVC coated barbed wire can be galvanized iron wire
A variety of colors like green, blue, yellow, orange, gray
Packing: In coil of 25 kilos or 50 kilos , lined with PVC strips, then wrapped with P.V.C or hessian cloth
Barbed wire weave types:
1) single strand barbed wire,
2) double strand double twisted barbed wire;
3) double strand common twisted barbed wire
Common Uses
1. the protection net in industry
2.agriculture,animal husbandy,dwelling houses
3.plantation of fencing,grass boudary
4. ranch and livestock farn, detention houses
5.railways and highways
5. Our product info:
wire Gauge: 16#-12#
Barb Wire Gauge: 16#-12#
Barbed length:1-3cm
Barbed spacing:7.5-15cm
Weaving way: Twist, standard
Surface finished: Electro galvanized,Hot dipped galvanized,PVC coated
Weight of packing in coil: 25kg/coil,50kg/coil as standard
Note: Customer request acceptable.
Features:
* Barbed wire has the feature of extremely difficult to cut and hard to climb.
* Barbed wire is very strong and reinforced with a steel coil which makes it very hard to bend, while the barbs have a piercing and gripping action.
* Barbed wire enjoys good appearance.
The manufacture machine and our factory
The packing
Plastic inside, hessian outside Plastic inside,waving bag outside
1)in nude 2)in iron axletree 3)in wood axletree ; 4) in wood pallet
Specification List
Gauge of | Approximate Length per Kilo in Meter | ||||
Barbs Spacing 3" | Barbs Spacing 4" | Barbs Spacing 5" | Barbs Spacing 6" | ||
12x12 | 6.0617 | 6.7590 | 7.2700 | 7.6376 | |
12x14 | 7.3335 | 7.9051 | 8.3015 | 8.5741 | |
12-1/2x12-1/2 | 6.9223 | 7.7190 | 8.3022 | 8.7221 | |
12-1/2x14 | 8.1096 | 8.814 | 9.2242 | 9.5620 | |
13x13 | 7.9808 | 8.899 | 9.5721 | 10.0553 | |
13x14 | 8.8448 | 9.6899 | 10.2923 | 10.7146 | |
13-1/2x14 | 9.6079 | 10.6134 | 11.4705 | 11.8553 | |
14x14 | 10.4569 | 11.6590 | 12.5423 | 13.1752 | |
14-1/2x14-1/2 | 11.9875 | 13.3671 | 14.3781 | 15.1034 | |
15x15 | 13.8927 | 15.4942 | 16.6666 | 17.5070 | |
14x16 | 15.3491 | 17.1144 | 18.4060 | 19.3386 |
- Q:I am connecting a humidstat to furnace. I would normally use furnace/thermostat wire for this purpose except that I need 8 conductors and the largest furnace/thermostat wire seems to be 5 conductors. I would like to use another 18guage 8 conductor wire but not sure if there are any specifications I need to ensure it meets before I can use it inside furnace cabinet.
- they do make 8 and ten conductor stat wires but in a pinch you could run two 4 conductor wires side by side. just make sure you mark at both ends becayse you will have 2 of each color wire. mark them as red 1 and red 2, etc.
- Q:Hello,I'm trying to replace my old ceiling fan with a new one but i can't seem to figure out the wiring.I have three wires coming out of the ceiling: 1) Two white ones that were connected together when the old ceiling fan was installed2) A grey wireI have four wires in the new fan:1) Black2) Black and White (would connect with the black based on the instructions)3) Green Grounding4) WhiteCan you help me figure out the connections. Thanks!
- the two connected means a continous circut. Means it goes to something else. Tie the two blacks, from the fan with the grey. Your fan must have a light. And the white to the white. Your just compleating the circut. Cant really mess it up. green is ground ofc
- Q:circuit breakers,equipment,wire,or people
- Fuses protect against short circuits but need to be replaced when they blow. Circuit breakers trip to protect against short circuits and can be reset once the problem is fixed. A corollary of Murphy's law for electronics states that the most expensive, difficult to access and unobtainable component will protect both circuit breakers and fuses by blowing first.
- Q:My renter took apart a timer that was hooked to a ceiling fan because the timer was clicking loudly.Now, I just want to simply install a normal on/off switch in it's place. There are two sets of wires coming into the box. One set has a red,white, and black wire coming from it. The other set has just a white and black wire coming into the box. I'm sure this is relatively simple for someone who has wiring expertise. How do I wire a normal light switch to these wires?!?!
- The set of black and white wires are coming from your breaker box (supply). The Black, white and red wires are leading to your ceiling fan (demand). This next part depends on how your fan is wired up. You will want to check first. USUALLY, the red wire controls the fan only, while the black wire supplies power to the light kit, but it could be reversed. This is the part that you want to check. The red wire may also be capped off in the ceiling box and only exists if the user wants separate fan/light control in the future. Assuming that the red wire is capped off: 1.) Turn off the breaker supplying the circuit you are working on. 2.) Use a wire nut to twist the white wires together. 3.) Use a second wire nut to cap off the red wire. 4.) Wrap the black [supply] wire clockwise around the bottom screw on your new switch and tighten.. 5.) Wrap the black [demand] wire clockwise around the top screw on your new switch and tighten. 6.) Attach the new switch to the wall box while carefully tucking the wires in behind the switch. 7.) Install cover plate. 8.) Restore power to the circuit. It IS possible that the person who installed the ceiling fan used the red wire as the hot instead of the black. If this is the case, you can either rewire the ceiling fan's box accordingly (disconnecting the red wire and using the black instead) or substituting red instead of black in the instructions above. The red wire would then connect to the top screw terminal of your switch. If the red is connected to the light kit (if applicable) and the black is connected to the motor (or vise versa), disconnect the light kit and wire it along with the motor.
- Q:How do I wire with reg 5 wire T-Stat Installing a 2 ton Goodman A/C cond unit to a old Carrier Heat pump AHU with emergency heat strip.
- red is your low voltage green is your fan yellow is your cool brown is your com orange is your heat how many wires do you have on the old one should be color to color
- Q:I got a ventilation fan for the bathroom. The fan has 2 wires and there are 2 wires sticking out of the wall.How do I know which wire connects to which wire?What would happen if I connect the wrong wires?
- Of the two incoming wires, one should be white (neutral) and one should be black (hot or power). The bath fan should have a neutral and hot also. A wiring diagram can usually be found on the fan unit if a manual is not available. Simply wire the white/neutral to the neutral wire of the fan and do likewise for the hot wire. For safety modern fans make accommodations for the attachment of a ground wire. This provides a path to ground should there be a short in the unit. Hopefully there is a third wire from the wall that will provide a ground. It is usually bare and should be attached to the fan using a green ground screw. Older homes did not have the third ground wire but unless your home is from the fifties, you should have three wires. (If your electrical outlets accommodate three prong plugs, you have grounded wiring). If your bath fan is relatively inaccessible (on the ceiling) not having it grounded might not be that big of an issue but it is always better to ground the bath fan frame when possible. Again, if you have or can locate the manufacturers wiring diagram it should be followed.
- Q:I just tore my old shed down, that was wired for electrical. though I never used power out there There is size 10 wiring (two wires), running from the house to where my shed was. I then bought a Tough Shed from The Home Depot and put it where my old shed was. While working on wiring my new shed for electricity, I turned power off to the entire house.I am trying to install power to the shed and I spliced the size 10 wires to size 14 (three cable, includes a ground) which I have connect to an electrical outlet in the shed, but once I turn the main power box back on, the circuit that runs power to the shed keeps tripping off. Am I missing something here?Thanks
- GET A PRO,...................or atleast someone that knows enough about electricity not to make a death - trap
- Q:I have a 98' F-150 and need to add a 4 flat trailer wire connector to it. What all do I need to do? Is their a special connector?
- go to your local auto parts store and ask the counter guy about trailer wiring. he should show you the right stuff
- Q:What fabric is the wire made of? What are the advantages and disadvantages?...
- The overall fabric, the wire about 3%~8% or so, under the same general level of technology, the higher the proportion of metal wire.
- Q:I have some salvaged wire from a computer power supply and would like to know it's break-down voltage rating. Most hookup wire is rated at 600 volts but unfortunately, all computer stuff is now made in China. The repair job of a vintage piece of equipment requires wire that can withstand 300 VAC.
- Computer power supply cables do not deliver anything like 300 volts, so I would say no, don't risk it.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Hot dip/ Electric galvanized Double Twist Barbed Wire Fencing Real Factory (ISO)
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 m.t.
- Supply Capability:
- 5000 m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords