• Horizontal Single Stage Fire Pump System 1
Horizontal Single Stage Fire Pump

Horizontal Single Stage Fire Pump

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
5000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Description

horizontal single stage fire pump is newly developed according to market needs.Its performance,technical conditions conform with international standard ISO2858 and requirements for national standard GB6245-2006《Performance requirements and test methods for fire pumps》.

Applications

It has been widely used in fire fighting and living water supply of industry the residence buildings.

Parameter range

Inlet diameter :50-200mm(2"-8")

Capacity:5-110L/s

Head:0.31-1.27MPa

Rate of rotation:2900r/min、1450r/min

Power:4-110kW

Two seal types: stuffing seal or mechanical seal

Structural Characteristics

  XBD-I series horizontal single stage fire pump set is mainly made up of 1.pump cover 2.impeller 3.shaft 4.seal ring 5.packing ring 10.Suspension bearing parts 12 .etc.

  Pump casing and pump cover of XBD-I series horizontal single stage pump are split from back of impeller,namely,back-open structure.It is convenient to maintain,when maintaining,pump casing,suction pipe,discharge pipe shall not be dismantled,so rotor parts can be taken out for maintenance easily.

   Pump casing(namely,pump body and pump cover) composes pump working room.Impeller,shaft and rolling bearing are rotors of pump.Suspension bearing parts support the rotor parts,and rolling bearing bears the radial force and residual axial force of pump.

    To balance the axial force of pump,there are seal rings on the front shroud and back shroud of impeller,and there is balancing hole on the impeller back shroud.Some of the pumps do not have too much axial force,so there are no seal ring or balancing hole on the impeller back shroud.

    Pump seal is made up of packing gland 9,shaft sleeve 8 and packing 11,or mechanical seal is applied to avoid air getting inside or too much water leakage.

    There is a shaft sleeve through the packing cavity to avoid shaft abrasion.There is o-ring between shaft sleeve and shaft to avoid the air getting inside or water leakage.

    Driving way of pump is connected through coupling and motor.Pump rotates clockwise from the direction of drive.

Q:What are the characteristics of the piston pump?
Piston pump is an important device of hydraulic system. It depends on the plunger in the cylinder in reciprocating movement, so that the volume of the sealing chamber volume changes to achieve oil absorption and oil pressure. Plunger pump with a rated pressure, compact structure, high efficiency and flow and easy adjustment, is widely used in high pressure and large flow and flow needs to adjust the occasion, such as hydraulic machine, engineering machinery and ships.
Q:How many concrete pump tube diameter
Different pipe diameter is different, most of the 125, there are 150. Now we have the smallest pump on the market, with a pipe diameter of 100.
Q:Difference between pump and compressor
Working principle:The impeller is installed in the pump casing and is fastened on the pump shaft 3, and the pump shaft is directly driven by the motor. There is a liquid suction in the center of the pump shell, and 4 is connected with the suction pipe 5. The liquid through the bottom valve 6 and the suction tube into the pump.The liquid discharge port 8 on the pump housing is connected with the discharge pipe 9. Before the pump starts, the pump shell is filled with the liquid to be transported; after starting, the impeller is driven by the shaft to rotate at high speed, and the liquid between the blades must also rotate. Under the influence of centrifugal force, the liquid is thrown from the center of the impeller to the outer edge and obtains energy, and leaves the outer edge of the impeller at high speed to enter the volute pump shell.
Q:How to install, operate and maintain the pipeline booster pump?
When the pump leaks, check it immediately to prevent leakage. If it leaks with the motor connection, replace the mechanical seal. Check that the power is connected. Is the supply voltage consistent with the operating voltage of the pump?. If the above a and B are normal, please remove the pump, open the pump cover, remove the foreign body in the pump, and then pump the lid on, and then tighten it to normal.No water pump, pump installed in the tap water pipeline, such as tap water level in the pump impeller on the plane (horizontal installation) or center line (vertical) below, you should turn off the power supply, to tap water level rise more than the impeller plane or the center line, connected to the power supply, to avoid mechanical damage (automatic no need to turn off the electric type). When the pump used in pumping wells, please check whether the water inlet pipe leak; pump cavity storage is not enough, should be filled with water, whether the suction process is too high, proper adjustment. Check whether the inlet and outlet diameter is too small or blocked. Automatic type after a period of time, there may be automatic failure phenomenon, mainly stainless steel and other metal products in pipes, long-term precipitation to shut off the power supply after unloading, unscrew the top screw, remove the plastic sheet to be cleaned, and then, according to the original reset, the normal debugging, can be re used.
Q:Centrifugal pump flow, why can be adjusted through the outlet valve? Can the flow of the reciprocating pump be adjusted in the same way?. Why
First of all, we know that pump according to the principle of work is divided into speed and volume type, centrifugal pumps are speed type, and reciprocating pumps are volume type.The centrifugal pump can adjust the flow through the outlet valve and outlet valve opening can determine the pump flow and head performance curve parameters such as specific relationship between the outlet flow and pressure can be provided by the data pump manufacturers endplate that even close the outlet valve of the pump pressure will also have a fixed value, but not allow zero flow pump operation, vibration caused by damage to the pump on the mechanical seal is not good and so easy to cavitation, set the minimum reflux line.
Q:What are the causes of pump shock?
6., water pump relatively serious cavitation, improve the water level of the water tank, reduce water output7., impeller and motor rotor imbalance, overhaul8. pump shaft bending or abrasion overhaul
Q:Brief description of centrifugal pump on / off operation
(3) check whether the turning rotor is easy and flexible, check the pump body is clang or friction sound.(4) the protective cover is installed, and the shield contact.(5) clean the pump frame and do a good job of sanitation.(6) open the inlet valve, make the liquid full of pump body, open the vent valve, clean the air and close it. If the hot oil pump, it is not allowed to open the air valve exhaust, to prevent hot oil channeling spontaneous combustion, if there is a dedicated vent pipes and tanks, you can vent the pipe line air and cold oil.(7) the hot oil pump should be preheated slowly before starting. Especially in winter, the pump body and the pipe should be preheated at the same time, so that the temperature difference between the pump body and the conveying medium is below 50 centigrade.(8) the oil must be sufficiently dehydrated before being introduced into the oil pump.
Q:The difference between diaphragm pumps, vacuum pumps and centrifugal pumps
The function of vacuum pump is to make vacuum, which has many kinds of structure, such as centrifugal, diaphragm (diaphragm), piston, liquid ring, rotary plate, jet type...................
Q:How long does the fine stone pump need maintenance? What should I pay attention to?
Check the line from the relief valve to the cylinder inlet to ensure that there is no external drainage or deformation due to impact and wear and that the connections are complete and fully tightened. - replace any damaged pipe immediately. - change the original settings strictly: all adjustments and calibrations can only be done by professionals. - no fucks hydraulic components, otherwise manufacturers on product warranties and liability shall not be responsible for. A warning because the hydraulic oil can reach very high temperature, there is the danger of burns, so open pipe fittings should take appropriate protective measures. Any replacement parts must conform to the level specified by the manufacturer. 8.2 check lubrication grease pump in oil at any time to ensure adequate and clean the lubrication pipeline joints without overflow phenomenon. Check the lubrication of the running parts at any time, and find the parts which lack oil, and check them immediately to prevent accidents. - check that the centralized lubrication system is effective daily. When the grease pump is empty, the grease added is often not easy to pump out because of the bubble. In this case, open the outlet of the pump, run the grease pump until the grease is re flowing, and then connect the pipe
Q:What is the difference between centrifugal pump and positive displacement pump?
The centrifugal pump is usually driven by an impeller, and the head has a functional relationship with the flow rate. Positive displacement pump is gear or piston drive, each stroke output flow is constant, and the head does not matter, the pressure head can be infinite.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords