Horizontal end-suction centrifugal Pumps with Good Quality

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
5000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Packaging Detail:standard export plywood case
Delivery Detail:15-20days

Specifications

1,Single-stage single-suction 
2,Axial suction centrifugal pump 
3,Back-pull-out design

Min inlet pressure

Min inlet pressure depends on NPSH +0.5m safety margin + gasified pressure. It should be re-calculated the inlet pressure if one of the following happens.

*The liquid is more warm.

*The flow exceeds the nominate value.

*Suction distnace is very long or inlet pipe is very long.

*System pressure is too little.

*Inlet pressure is low.

 

Typical application

*Clean, thin, non-corrosive, non-flammable or non-explosive liquid without grain or fiber.

*Water supply system

*Heat, air condition system

*Irrigating, farming

*Booster, constant pressure water supply

*Industry cooling, heater circulation system

*Firefighting, splitting system

*Industry transferring, drainage system

 

Construction

*Non-self-priming, single stage, single suction, horizontal, axial suction and radical discharge, pump body is fixed by base.

*Use bering cradle, which can orientate bearing, prevent from radical vibration, improve the rigidity of rotary part.

*Compacted shaft, use deep grove grease lubricated roller bearing.

*Connect pump and motro with semi-flexible coupling.

*Use standard wearable mechanical seal.

*TEFC motor, size complies to IEC standard, installation type B3.

*The dimensions is conform to ISO 2858

 

Specificaton

*Flow: Max 520m3/h

*Power:Max 160Kw

*Head: Max 160m

*Liquid temperature: -15°C - 110°C

*Working pressure: Max 16bar

*Inlet and Outlet diameter: Inlet diameter: DN50-DN200; Outlet diameter: DN32-DN150

 

Curve conditions

*Curves tolerance is according to ISO9906, Annex A;

*All curves are based on the measured value of constant motor speed 2900rpm, 2950rpm, 1450rpm or 1480rpm.

*The measurements were made with airless water at temperature of 20°C. The curves apply to a kinematic vis-cosity of 1 mm2/s (1 cst)

 

Features

*Back-pull-out design, without having to disurb pump body and pipelines when servicing.

*All the models only use 4 kinds of pump shafts and bearing cover, make parts exchangeable.

*Impeller is optimum design, inlet is enlarged, no whirlpool, deduct the water pump NPSH efficiently, which makes pump work stable with little noise.

*Casing and casing cover use wearing neck ring structure, which makes pump easy to maintain, makes parts work longer. The replaceable seal ring, makes pump work efficiently in a long time.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What are the important parameters of the pump?
Because the lift refers to the effective energy, pump output unit of heavy liquid obtained from the pump so that the product of head and the mass flow rate and acceleration of gravity, is the effective energy output from the pump in unit time of liquid -- effective power pump:Pe= P gQH (W) = QH (W)In the p - density of liquid pumping (kg/m3);Gamma - pump heavy liquid delivery (N/m3);Q - pump flow (m3/s);H - pump lift (m);G - gravitational acceleration (m/s2)The shaft power P and effective power Pe is the difference of power loss in the pump, the size of the pump efficiency to measure the efficiency of the pump. As the effective power and shaft power ratio, with ETA said.
Q:Fire pump control cabinet There are 6 pumps, two indoor fire hydrant pumps, two spray pumps, and two outdoor pumps
You said the three line refers to the control room, the control cabinet, the main pump directly start the straight line of water pump. Each pump should be equipped with single straight line Kai, reported that the cabinet Jinglian dynamic multi line linkage control board has three buttons corresponding to a remote spray pump, fire hydrant pump, pump start outdoor fire hydrant. This requires three straight lines, from the cabinet to the three pump control cabinet, which is the 9 line you call. The water pump control cabinet is provided with a terminal for supplying a remote pump. By looking at the wiring diagram of the water pump control box, you can find the technical personnel of the control cabinet manufacturer if you can't find them.
Q:Does vacuum pump oil belong to dangerous goods?
Absolutely not. We often send oil by express or by freight. There are no problems at all. Don't be afraid, don't burn, explode
Q:What are the general water pump failure, how to repair?
Two, pump speed is low(1) human factors. Some users because of original motor damage, may be accompanied by another motor, resulting in a flow of small, low head or even the consequences of Sheung shui.(2) the mechanical failure of the pump itself. Impeller and pump shaft fastening nut loose or deformation of the pump shaft bending, resulting in multi impeller, directly with the pump body friction, or bearing damage, are likely to reduce the pump speed.(3) the maintenance of the power machine is not working. The motor is lost because of winding burn, the change of winding number, wire diameter, wiring method, or failure in maintenance can not change the pump speed.
Q:How many pumps does the 80cm tank use?
Filter pump to select the water per hour can be filtered more than 3 times, I personally feel that this is almost enough. Of course, the more times the better, but also consider that if the pump is too large, the water inside the tank will be too large.128X3=384LThat is, the flow must be more than 384L/H of the water pump.You can buy a bigger pump, because the pump for a long time there will be some attenuation and domestic things in general to sign data, so it should be based on your actual situation to buy. Taobao on this category is about 20~40 yuan.
Q:What is double hydraulic pump?
Two hydraulic pumps installed on one shaft can be connected to increase output flow, and can also be connected to increase output pressure. See how the demand is. The system can change the mode of application at any time.
Q:What is the lift of diaphragm pump?
Diaphragm pump lift is different from the centrifugal pump, refers to the diaphragm pump can raise the height of water, the unit is meters water column. Lift depends on the size of the outlet pressure, the pressure per kilogram is equivalent to 10 meters height
Q:How should the water pump be installed?
(8) check the suitability of the foundation and whether the size of the foundation corresponds to the size of the pump.(9) find the position of positive pump and motor, pump set and anchor bolt and the inlet and outlet flanges, to ensure that the flange torque of the pump conforms to the standard. Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition. It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
Q:Is vane pump good or gear pump good?
The main working parts of vane pump is provided with a plurality of sliding vane rotor, when the rotor rotates, the eccentric configuration of stator cavity contour or rotor, blade sliding slot in leaves due to volume changes, resulting in the suction effect. The similarities are: 1, rotary type positive displacement pump has self-priming ability, but are not allowed to do; 2, with continuous flow pulsation, but also have flow and pressure; 3, the theory of flow is determined by the working parts of the size and speed, has nothing to do with discharge pressure; 4, rated discharge size, pressure and working parts mainly depends on the pump speed is independent of the sealing parts and bearing capacity; differences: 1) gear pump structure is more simple, reliable, low price; vane pump has complicated structure and high manufacturing precision parts, the blade is easy to get stuck, more sensitive to the oil clean degree and viscosity.
Q:What are the basic technical parameters of the pump?
Two, pump head H head is the unit weight of the liquid pump pumping from the inlet of the pump (pump inlet flange) to the outlet of the pump (pump outlet flange) energy value. Effective energy is a Newtonian liquid through the pump unit is obtained. The N m/N=m, the height of liquid column pumping liquid. Habits referred to as meters. Three, the pump speed is n RPM pump unit time revolutions, represented by the symbol n, the unit is r/min. four, the pump NPSH NPSH NPSH is also called net positive suction head, said main parameters of cavitation performance. Cavitation has been used a h power of five, the power of the pump. And the efficiency of the pump is usually refers to the input power, which is the prime mover on the pump shaft power, it is also known as the shaft power, denoted by P;

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range