Horizontal end-suction centrifugal Pumps with Good Price

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
5000 unit/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Packaging Detail:standard export plywood case
Delivery Detail:15-20days

Specifications

1,Single-stage single-suction 
2,Axial suction centrifugal pump 
3,Back-pull-out design

Min inlet pressure

Min inlet pressure depends on NPSH +0.5m safety margin + gasified pressure. It should be re-calculated the inlet pressure if one of the following happens.

*The liquid is more warm.

*The flow exceeds the nominate value.

*Suction distnace is very long or inlet pipe is very long.

*System pressure is too little.

*Inlet pressure is low.

 

Typical application

*Clean, thin, non-corrosive, non-flammable or non-explosive liquid without grain or fiber.

*Water supply system

*Heat, air condition system

*Irrigating, farming

*Booster, constant pressure water supply

*Industry cooling, heater circulation system

*Firefighting, splitting system

*Industry transferring, drainage system

 

Construction

*Non-self-priming, single stage, single suction, horizontal, axial suction and radical discharge, pump body is fixed by base.

*Use bering cradle, which can orientate bearing, prevent from radical vibration, improve the rigidity of rotary part.

*Compacted shaft, use deep grove grease lubricated roller bearing.

*Connect pump and motro with semi-flexible coupling.

*Use standard wearable mechanical seal.

*TEFC motor, size complies to IEC standard, installation type B3.

*The dimensions is conform to ISO 2858

 

Specificaton

*Flow: Max 520m3/h

*Power:Max 160Kw

*Head: Max 160m

*Liquid temperature: -15°C - 110°C

*Working pressure: Max 16bar

*Inlet and Outlet diameter: Inlet diameter: DN50-DN200; Outlet diameter: DN32-DN150

 

Curve conditions

*Curves tolerance is according to ISO9906, Annex A;

*All curves are based on the measured value of constant motor speed 2900rpm, 2950rpm, 1450rpm or 1480rpm.

*The measurements were made with airless water at temperature of 20°C. The curves apply to a kinematic vis-cosity of 1 mm2/s (1 cst)

 

Features

*Back-pull-out design, without having to disurb pump body and pipelines when servicing.

*All the models only use 4 kinds of pump shafts and bearing cover, make parts exchangeable.

*Impeller is optimum design, inlet is enlarged, no whirlpool, deduct the water pump NPSH efficiently, which makes pump work stable with little noise.

*Casing and casing cover use wearing neck ring structure, which makes pump easy to maintain, makes parts work longer. The replaceable seal ring, makes pump work efficiently in a long time.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the pump lift voltage? And how to suppress the pumping voltage rise?
The elevator is mainly used by the power grid through the rectifier, filter, inverter and other transmission to the motor. The motor in high speed when the brake suddenly, but the rotor of the motor with the load (production machinery) mechanical inertia, could not stop quickly, resulting in the back EMF (EU voltage) motor is in the state of power, the reverse voltage and torque original electric state torque instead, and the motor with brake strong torque, forcing the rotor to stop fast but usually AC-DC-AC converter is the main power AC/DC rectifier circuit is irreversible and therefore cannot go back to the grid, energy will be accumulated in the filter capacitor, produce pump voltage, this phenomenon of pump voltage converter has great destructive power.
Q:How many square cables does the submersible pump for 7.5KW need?
I=P/ (1.732Ucos phi) =7.5/ (1.732X0.38X0.85) =13A (calculated according to three-phase city power, power factor 0.85).
Q:Troubleshooting of diaphragm pump
The troubleshooting guide for diaphragm pumps, when encountered in one or more of the following situations, this information can be used as a guide to help you develop maintenance measures.As shown below, some of the abnormal operating conditions described in this guide are: A) fast circulation / low flow B) no cycle / slow cycle / irregular cycle C) leakage D) noise E) component rupture
Q:What is the minimum continuous flow of a pump?
Quality solutionsMinimum flow of pump, minimum continuous flow of pumpIn order to ensure the proper use of the pump and the normal operation of the pump manufacturer will indicate the minimum pump in the sample of the continuous operation flow, the correct selection or use to warn or instruct users. According to the provisions of the API standard, the minimum continuous flow into the minimum continuous stable flow and continuous flow. Most small thermal limit(1) the minimum continuous stable flow.API standard specifies the minimum continuous stable flow refers to the vibration limit does not exceed the standard set by the pump can work normally. The minimum flow pump at small flow rate, there will be noise and vibration increase, API of this provision is to ensure that the service life of the pump, avoid due to improper operation of the pump caused by the adverse effects.
Q:What happens when a centrifugal pump is selected?
Centrifugal pumps are too big to measure.There is a reason why the centrifugal pump does not measure up:The pump inlet pipe blockage, leakage.The pump inlet pressure is too low.
Q:Bolus dosage of infusion pumpWhat is the purpose of the pill dose control in the special safety standard for infusion pumps? If the risk is not properly controlled, what is the degree of risk? And how can the open infusion pump be used in this regard?
Four) release bolus dosage method can use automatic release and manual release two ways, the key is to alarm after the infusion must be stopped(five) any kind of pill dose release are not restricted to replace the pill. The total dose limit for in pipe blockage after pill agglomeration process will remove blocking accident, this time will be the rapid infusion of pill dose concentration into the patient's blood, if the total dose pill does not get test and limit, rapid infusion of this accident it may have unimaginable consequences.(six) supplies open type infusion pump overflow on the domestic market for pill characteristic parameters of consumables simply without testing and limitation. Therefore, the risk of accidental pill has become one of the residual risk of open type infusion pump supplies the most deadly.
Q:Why does the centrifugal pump start and close first when the outlet valve is closed?
When the valve is closed off opposite is the first current to the rated current, avoid instant electricity loss of other electrical equipment caused by voltage fluctuation. At the same time, some centrifugal pump outlet check valve is not installed, the role of avoiding the pipeline caused by backflow of water pump reversal.This Regulation (or operation regulation) is generally applicable to larger power centrifugal pumps. For small power equipment, it can be used to determine whether the above operation is necessary for actual use
Q:What is the difference between centrifugal pump and rotary vane pump?
The vane pump can be divided into centrifugal pump, mixed flow pump and axial flow pump according to the direction of liquid flow in the impeller.Centrifugal pump is a kind of vane pump, which is the most widely used.
Q:5 floor water pressure is too low, what kind of water pump is better?
The location of the pump is too far away from the pumping pool, the suction of the pump is not enough, cavitation phenomenon, pumping water, this water pump manufacturers, the pump will be placed in a reasonable position
Q:What are the causes of pump shock?
3. the water pump set screws loose, adjust the concentric, fastening the foot4. pump into foreign body, open cover overhaul5. the flow is too large or too small, adjust the equipment to control the water output

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range