High Quality Double Insulated and High Tension Lead out Cable for Underground Electric Cable

Ref Price:
Loading Port:
Payment Terms:
Min Order Qty:
100 m
Supply Capability:
50000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Quick Details

Place of Origin:

Zhejiang, China (Mainland)

Brand Name:


Model Number:


Insulation Material:



Low,Medium and High Voltage


s electric power distribution networks or industrial installations

Conductor Material:

Copper or Aluminium




Non-hygroscopic Polypropylene(PP)

Binder Tape:

Non-woven fabric

Metallic Armour 1:

Galvanized Stainless Steel Tape Armour(STA)

Metallic Armour 2:

Galvanized Stainless Steel Wire Armour(SWA)

Metallic Armour 3:

Non-magnetic Steel Tape Armour(only for single core)

Metallic Armour 4:

Aluminium Wire

Packaging & Delivery

Packaging Details:wooden drum; iron-wooden drum or steel drum
Delivery Detail:Depending on the quantity


2015 new product electric power cable 
1 Conductor:Copper or Aluminium 
2 Insulation:PVC or XLPE 
3 Voltage:Low/Medium/High Vol

2015 new product electric power  cable  

Technical Parameters of our Power Cable 

1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890

2). Detailed description or construction:

    * Conductor: compacted or uncompacted copper or aluminium

    * Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)

    * Filler: Polypropylene filament with lapped binding tape

    * Binder: Binding tape

    * Inner sheath: Polyvinyl chloride (PVC)

    * Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)

    *Sheath: Polyvinyl chloride (PVC)

3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:

    U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV

4). Voltage:

     0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV

    In the voltage designation of cables U0/U(Um):

        * U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;

        * U is the rated power frequency voltage between conductors for which the cable is designed;

        * Um is the maximum value of the "highest system voltage" for which the equipment maybe used.

5). Application:

     For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.

6). Marking: According to the customers' requirements

High Quality Double Insulated and High Tension Lead out Cable for Underground Electric Cable

High Quality Double Insulated and High Tension Lead out Cable for Underground Electric Cable

High Quality Double Insulated and High Tension Lead out Cable for Underground Electric Cable

High Quality Double Insulated and High Tension Lead out Cable for Underground Electric Cable

High Quality Double Insulated and High Tension Lead out Cable for Underground Electric Cable

High Quality Double Insulated and High Tension Lead out Cable for Underground Electric Cable

High Quality Double Insulated and High Tension Lead out Cable for Underground Electric Cable


·         Can we make an OEM order?

o    We can offer or supply goods as customers' requirements.

·         How can I get some samples? Free or not?

o    We can send some normal samples, absolutely free.

·         How does your factory do regarding quality control?

o    "Quality is priority." We always attach great importance to quality controlling from the very beginning to the very end. Our factory has gained ISO9001 , SGS authentication, CE for Europe, etc.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Can a kink in the power or rca cables make my subwoofer not work?
RE: a thank you to make vehicle audio equipment clearer ( make bass in simple terms pass to subwoofers.)? I in simple terms positioned 2 10 inch Kicker L7's into my vehicle with a 1300 watt amp. those subs band somewhat difficult and that i like them yet, I even have one situation. as quickly as I attempt to look the music loud the front audio equipment start to grow to be distorted. i will't be sure a thank you to deliver the bass just to the subwoofers. I...
Q:could I use an 8-pin PCIe power cable for 8-pin m/b or not?
Q:We say that the size of power cable is 4 core, 150 sq.mm. What would be the diameter of this cable ???
A 4core (electrical) cable of that strength is usually built up from quarter circle shaped sectional wires. (Think of a pizza cut into four even pieces.) So, calculate the outside diameter from this point and add 4 times the insulator thickness. Example: 400V 4core cable has very likely 1mm insulator thickness. 150mm² * 4 cores is 600mm² total. By A=PI*d'*d'/4, d' being the diameter without insulator, would be d'=2*sqrt(A/PI)=600mm²/3.1415...=2*sqrt(...‡ Now, as said above, add the 4 insulator layers, and then you would be at approx. 31.7mm outside diameter.
Q:PCI Express Power Cable Questions Problems.?
you can purchase a molex to 6 pin pci express power adapter, this will fix the problem. This solution will work only if you have a spare molex connector you are not using Forget about what that other person said, that your power supply isn't big enough. 650w is more than enough to power a mid to high range graphics card
Q:Why dont overhead power cables have rubber/plastic cover so that if they fall they cant cause serious injury?
One small addition to what has been said above, and that seem to have been forgotten: When a power cable breaks and falls to the ground, it acts exactly like a whip! It does not matter if it were covered with feathers, the simple whipping force would STILL cut a car in two... (I have seen a cable cutting a HOUSE in two!)
Q:Power and Ground Cables?
you could go to walmart and get a kit for about $50
Q:Ipad charge does not enter the charge does not support this accessory charge
Friends, my task, hope to adopt! Answer: sorghum (Liang) explained: the poles are relatively high, beautiful riding on the poles is in the height of their own beautiful, so according to the meaning of harmony, the answer is sorghum.
Q:150,120,95,50,25,10,4 * 1.5,2 * 1.5 how much cable to use the heat shrink tube
Due to the circumstances of the question .. at any time questioned us
Q:ethernet cables explain. what are the 2 leftover power cables.?
Generally there should NEVER be power on cat5, this breaks the low voltage cable regulations of almost every country in the world. The 1 and 2 pair and the 3 and 6 pair are normally data for network. Th 4 and 5 are normally for telephone and should not really be used at the same time. Most network equipment now short circuits this pair as protection against the much higher voltage (up to 90v) of telephone lines, and continuous shorting of these lines can cause equipment damage. The 7 and 8 pair are generally unused, but are sometimes used for rf to rj45 baluns used to pass video down the line. It is possible to use all these on one cable, but makes absolute nonsense of the purpose of structured cabling.
Q:will leaving the power cable in for my laptop hurt the battery?
Newer batteries cannot be overcharged but it is not advisable to leave the power cable plugged in when the battery is at a full charge. It will not hurt the battery but overtime your battery will not sustain a charge for as long as it should. My best advice would be to fully charge and let your battery drain to near completion and then recharge. Give your battery the exercise it was meant to have.

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range