Item specifice
Bag tie wire is also called loop tie wire, bag ties, loopings, etc, it canbe divided into black annealed bag tie wire , galvanized bag tie wire , pvc coated bag tie wire.
1. Wire style:
Electro Galvanized Iron Wire
Hot Dipped Galvanized Iron Wire
2. Use:
Mainly used in communication equipment, medical equipment and weaving nets, brushes, cables, filters, high pressure pipe, construction, handicrafts and other industries.
we can be made according to customers specific requirements
3.Features of Galvanized Wire:
Material: low carbon steel wire
Tensile Strength: 400--580Mpa
Standard wire gauge for electro galvanized iron wire: From 8# to 16#
Hot-DIP galvanized iron wire standard wire gauge: From 8# to 24#
Material:
Black Annealed Iron Wire
Galvanized Iron Wire
PVC Coated Iron Wire
Application:
The loop tie wire as a binding wire used in packing or construction in rebar tie. It is easy to twist directly,Enhances the working efficiency, reduce pollution. both the wire diameter and length can be customized on request.
Securing trees, wines and creepers to supports and trellises, or erecting and joining support structures; Tying bags or as a mail or laundry bag seal.
Features:
easy to twist,
hard to break,
long life,
protection against corrosion, salt or abrasives.
Specification:
Wire Gauge | SWG in mm | BWG in mm | In Metric System mm |
13# | 2.34 | 2.41 | 2.50 |
14# | 2.03 | 2.11 | |
15# | 1.83 | 1.83 | 1.80 |
16# | 1.63 | 1.65 | 1.65 |
17# | 1.42 | 1.47 | 1.40 |
18# | 1.22 | 1.25 | 1.20 |
19# | 1.02 | 1.07 | 1.00 |
20# | 0.91 | 0.89 | 0.90 |
21# | 0.81 | 0.813 | 0.80 |
- Q:Hi,I'm looking to change the outlets and the switch and light fixture in a bedroom of a home built in 1948. The outlets are original to the home I think. Will I have to fish ground wire throught to the panel box for my new receptacles? Or just install new 2 slot outlets?Why the different looking wires?Is the older wire copper with a silver colored coating to indicate being neutral or is this an old aluminum wire? The hot wire is red plastic coated and looks modern to me.
- you've got some good answers so far. if the wire turns out to be aluminum then proceed with caution because aluminum wire in small sizes turned out to be a terrible idea. it will need a special receptacle. if the wire is bx wire as described in your first comment don't bother with those greenies he mentioned because simply screwing your device into the metal box will bond the ground together. it uses the 6/32 screws provided as an excellent grounding means. you may want to consider using GFCI receptacles as well. I've never seen a new hot wire and old neutral wire like you describe and I've worked on a lot of older houses. before you get into trying to rewire your house realize that this is a very time consuming and aggravating project that will require two people who really should have experience doing this. if you do it then invest in a long (like 4 foot) drill bit and some glow sticks.
- Q:I'm trying to fix a light fixture for a friend. Her father-in-law gummed it up. At the fixture, there are 3 white wires soldered to a single wire. There are 3 black individual wires and one red wire. There are three switches that control the light.If I hook one of the black and the 3 white to the light, the light stays on constantly. If I hook either of the two other black individually, nothing comes on period.I'm pretty much at a loss. Any advice would be greatly appreciated.
- Your wiring involves 2-3/way and 1-4/way switches plus a likely additional power circuit inside the junction box. Your wiring description does not contain enough info for anyone to instruct you in correct reconnection. You need to either call an electrician or let your friend's father-in-law fix it. Remember saying I don't know how to do this is nothing to be ashamed of.
- Q:If you hang a pot-plant with mass of 8kg from two lengths of wire attached to a horizontal beam 100cm apart. The wire on the left has a length of 50cm and the wire on the right has a length of 75cm.What is the tension in both wires?
- The tension in both wires.? If you hang a pot-plant with mass of 8kg from two lengths of wire attached to a horizontal beam 100cm apart. The wire on the left has a length of 50cm and the wire on the right has a length of 75cm. What is the tension in both wires? In the triangle ABC, AB(c) = 100 cm, BC (a) = 50 cm and AC (b) = 75 cm 2s = a+b+c = 225 cm s = 112.5 s-a = 112.5 - 50 = 62.5 s-b = 112.5 - 75 = 37.5 s-c = 112.5 - 100 = 12.5 tan A/2 = √ {(s-b)*(s-c) / [s*(s-a)] = √ {37.5*12.5) / [112.5*62.5] A = 28.95? tan B/2 = √ {(s-c)*(s-a) / [s*(s-b)] = √ {12.5*62.5) / [112.5*37.5] B = 46.57? C = 180-28.95-46.57 =104.48? --------------------------------------... 46.57? is the angle between horizontal and 50 cm wire. 28.95 is he angle between horizontal and 100 cm P is the tension in the 50 cm wire and Q is the tension in the 75 cm wire Equating the horizontal components of the tensions P cos 46.57? = Q cos 28.95 ? P = Q cos 28.95 ?/ cos 46.57? P = 1.27 Q-------------------1 Equating the sum of the vertical components of the tensions to the weight of the pot P sin 46.57? + Q sin 28.95 = 8*9.8 N 0.73P + 0.48 Q = 78.4N 0.73(1.27 Q) + 0.48 Q = 78.4N Q = 55.72 N and P = 70.76 N ============================= Or use Lamis theorm Angle between P and Q = 104.48? Angle between P and the pot = 90 + 46.57? Angle between Q and the pot = 90 + 28.95 By Lamis theorm P/ cos 46.57? = 78.4/ sin 104.48? P = 55.67 N and Q = (78.4/ sin 104.48? ) cos28.95 = 70.85N ====================================
- Q:Blue and white wires contain insulated strands and red wire has a bundle of non-insulated strands. How are the two types of wires (insulated and non-insulated strands) used in homes (i.e. what are they used for?).
- The bare wires in house power wiring is used as the grounding wire. I don't think you mean stranded wire. The wiring in your walls that goes to outlets and lights is solid wire. If you are just calling them a strand of wire, that is not a good idea because it is too easy to confuse with stranded, especially if you are not careful with proper grammar and spelling. The other insulated wires are used as hot and neutral. In most homes, white is the return/neutral line and the other colors (except green) are used for different phase of hot wires. If you have green insulated wires, they are used for ground.
- Q:The house was built in the 50's. Two wires are coming up from the switch and two wires are coming down from the top of the wall. I do not see a third wire. I attached the wall light wires left wires to left wires and right wires to right wires and light stayed on, when I moved the switch it threw the breaker. So I used may combination and the switch would not make the light work. It appears one wire may be white and one black. Help please!
- The wire coming down from the wall is probably the power line. The wire going to the switch is meant to switch the hot lead lead only. Check the wires on the switch. There is probably a black and white on the switch. You will want to hook the white wire coming from above to the white wire on the light. Hook the black wire coming from above to the black wire going to the switch. Hook the white wire coming from the switch to the black wire on the light. While you are at it take black electrical tape and tape both ends of the white wire that runs to the switch. This will indicate that it is a hot lead.
- Q:my rabbit is chewing wires and in one area in my room there are like 300 wires i was just wondering if i can spray something on the wires cause i thought i saw something that said that please help!!!!
- well you could but I would not guarantee it working. Wires are just a bunny magnet. Bunnies often actually like spicy, bitter tastes. I had one that liked bitter apple. Really best is out of reach out of danger. You could keep bunny out of that room or cover the wires. Furniture the bunny cannot fit behind, large diameter aquarium tubing, for multiple wires all going to the same place even sump pump hose. For my computer desk I installed a baby gate.
- Q:can anyone please tell me what does hook-up wire mean and how does it differ from other kinds of wires such as light duty and heavy duty?Also,which one should I use for breadboards?
- Hookup wire is a term usually reserved for wire sizes smaller than 16 AWG, usually single strand conductor. It is generally used in applications where current-carrying capacity is not of prime importance. Breadboarding is one of these applications, but usually uses 22AWG or smaller wire.
- Q:Hello my question are:Examples given for wired and wireless communications systems?Compare and contrasted how wired and wireless communications systems function? Assessed the risks associated with wired and wireless communcations systems?(if you can put in simple details that would be helpful, because I understand parts of it but not all)Thank you
- I additionally want under pressure out. i began out with instantaneous, however the mouse only went by hundreds of batteries, and can crap out on me while i replace into authentic interior the midst of something. Now i take advantage of a under pressure out mouse. My keyboard continues to be instantaneous nonetheless.
- Q:Hello,I am trying to figure out what type of metal jewelry wire I need for a beading project. I found mostly copper wire at the craft store, as well as a smaller variety of aluminum and brass wire. Is this copper wire (came in many colors) a durable wire? It seemed very soft. Is there a stronger wire on the market? I am mostly looking for 22-28 gauge wire. Thanks!
- There okorder / and also look at the page on wire gauge chart. Hope this will help you to purchase the correct wire for your project.
- Q:im hooking a amp up and i need to run my remote wire to my ignition wire
- I have wired up alot of amps and the remote wire on the amp should be connected to the power antenna/amp turn on wire on the stereo head unit. This allows the amp to only turn on when the stereo is on. If you are connecting an amp to a factory stereo,I see why you would need to find an ignition wire. You need to probe the fuse panel with a 12 volt test light to find a circuit that only comes on with the key. Usually there is a spare accessory fuse location just for this. Buy a fuse tap or specialty fuse from a auto parts store to connect your remote wire to. There is very little current draw to turn on the amp,so almost any circuit on the fuse panel will work if it is only on with the key.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Galvanized Wire/Double Loop Tie Wire High Quality
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 5 m.t.
- Supply Capability:
- 50000 m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products