Specifications

1.220V Single Phase Variable Frequency Drive 2.2KW
2.Advanced control technology
3.Easy to operate

    220V Single  Phase Variable Frequency Drive 2.2KW

 

General

 

CNBM  frequency  inverter is a high-quality, multi-function,

low-noise variable frequency drive which is designed, developed and manufactured according to international standards.

It can meet different needs of industrial conditions.

The inverter applies advanced control technology of space voltage vector PWM, with functions of constant voltage control, power-off restart, dead zone compensation, automatic torque compensation, online modification parameter, high-speed impulse input, simple PLC and traverse.

 

 

Product Name:CMAX-VCG15/P18.5T3 ~ CMAX-VCG18.5/P22T3

 

Application

 

 

Textile: coarse spinner, spinning frame, wrap-knitting machine, loom, knitting machine, silk-spinning machine, etc.

 

Plastic: extruder, hauling machine, decorating machine, etc.

 

Pharmacy: mixer, roaster, etc.

 

Woodworking: engraving machine, sander, veneer peeling lathe, etc.

 

Papermaking: single type papermaking machine, etc.

 

Machine tool: non-core grinding machine, optical lens grinding machine, cutting mill, etc.

 

Printing: cloth-washing machine, dye vat, etc.

 

Cement: feeder, air blower, rotary furnace, mixer, crusher, etc

 

Fan and pump: kinds of fans, blowers and pumps

 

 

Specification

Item

Specification

Input

Input voltage

220/380V±15%

Input frequency

47~63Hz

Output

Output voltage

0~input voltage

Output frequency

0~600Hz

Peripheral interface characteristics

Programmable digital input

4 switch input, 1 high-speed impulse input

Programmable analog input

AI1: 0~10V input

AI2: 0~10V input or 0~20mA input,

Programmable open collector

output

2 Output

(3.7kW and above: 1 Open collector output)

Relay Output

1 Output (3.7kW and above: 2 Relay output)

Analog output

2 Output, one is 0~10V,

another is 0~20mA or 0~10V

Keypad

Display:5-digit 8-section LED (Red), 2 indicators; parameter setting: 8 keys (including multi-function hot key ), 1 potentiometer

Technical performance characteristics

Control mode

All digital space voltage vector SVPWM algorism

Overload capacity

G purpose: 150% rated current 60s

P purpose: 120% rated current 60s

Speed ratio

1: 100

Carrier frequency

1.0~10.0kHz

Torque compensation

Linear, multi-point, 1.3th power, 1.7th  power, 2.0th power reduced torque; Compensation voltage range: automatic compensation and manual compensation 0.1~10%

Automatic voltage adjustment

It can automatically maintain output voltage constant when grid voltage fluctuates.

Automatic current adjustment

When the current is over current limit, under clocking automatically limits output current.

Function characteristics

Frequency setting mode

Keypad digital analog input, keypad potentiometer, impulse frequency, communication, multi-step speed and simple PLC, PID setting and so on, switch-over of setting modes.

Simple PLC,

multi-step speed control

16-step speed control

Special function

Traverse control, length control, time control

QUICK/JOG key

User-defined multi-function hot key

Protection function

Over-current, Over voltage, under-voltage, over-heat, phase failure, over-load and motor over-load

Working condition

Installation site

Indoor, altitude of less than 1km, dust free, non-corrosive gases, no direct sunlight

Application environment

-10°C~+40°C, 20~90%RH (no dew)

Vibration

Less than 0.5g

Storage temperature

-25°C~+65°C

Installation type

Wall-mounted type, floor cabinet type

Cooling mode

Air-forced cooling

 

 

Q: What's the frequency converter for? What does it look like?
The inverter is mainly used in industrial equipment, such as power plants, water plants, water supply equipment, large pumping station, it is basically a cuboid, a digital display control panel; and in the English show types into the universal type, fan pump type, vector control, different types should be used in different working conditions, voltage grade from 220V-10 million volts, currently has the localization.
Q: First of all, I would like to achieve the frequency converter with motor static linear acceleration, high-speed linear deceleration stop processFirst question: I say kind of situation, three paragraph speed start, 0.1hz---> high 30hz-->0.1hzSecond problem: manual speed instruction 1, speed 2, speed 3 instruction instruction I want to use PLC to control three speed motor with three reverse contact dry. I understand speed instruction 1 is switched on (2, 3 connected) transmission section set the frequency with the frequency segment set 0HZ123 AssociationThird questions: manual section, speed command, main frequency and STEP1-STEP7 stage setting frequency, I use PLC analog to the frequency main frequency setting, plus and deceleration, STEP1-7 are set 0, can achieve what I wantInitial contact frequency converter, home pointing
Control the three section speed inversion section, the speed instruction setting surface needs three frequency (M series frequency converter P-17, P-18, P-19) beforehand, which frequency conduction section fast contact line is needed
Q: What is the function of a frequency converter on an electric motor?
Mainly for AC motor speed regulation, but also is a smooth stepless speed regulation. You can also implement some specific controls.
Q: There is a feed and send system. Now due to the severity of the material is not the same as the two converters often change speed, the workers do not understand their own, often by, often bad now how to use the best way you can use a potentiometer or other method, control of the two frequency converter, synchronous operation. Is to adjust one, and the other also with the kind of frequency, so that you can let the workers themselves to open, and the two inverters, the same manufacturer, the same model, the same load,
Two start with frequency conversion. The frequency converter is controlled by a potentiometer, and the analog output signal (AO.GND) is sent into the converter and connected to the AI.GND port of the converter. If the pulse port can also be connected to the pulse port.
Q: What does "EPCU" mean in a frequency converter?
This code indicates external signal interference.It is possible that the power line and the signal line are coming together to check that the ground of the converter is ready.If not yet, that can only be considered in the inverter output end of the inverter output filter, or inverter output reactor to try.Frequency converter (Variable-frequency, Drive, VFD) is the application of frequency conversion technology and microelectronics technology, by changing the power supply frequency of the motor to control AC motor power control equipment.
Q: Why does the frequency change when the frequency converter regulates the frequency?
Main flux of motorM = U/ (4.44*f*N)In the upper model, the U is the stator voltage, that is, the output voltage of the inverter, f is the frequency, and N is the stator winding turn number.N is a constant.Obviously, when the frequency changes, if the voltage is constant, then the flux will change.The iron core of the motor is nonlinear, and when the flux changes, both too large (saturated) or too small (weak magnetic) is detrimental to the motor.Therefore, when changing the frequency, the voltage is changed, and the constant value of U/f is kept, so that the magnetic flux can be kept unchanged.
Q: Does the number of inverter settings differ from the number of motor poles, and does it affect the use?
1. motor speed control will not be accurate2. the working current of the motor may become larger, and the motor will be burnt out3., excitation what will change, but also may cause the motor heating, burnout, will also reduce the efficiency of the motor;4. may also burn the inverter.5. motor output may be affected.
Q: Is the voltage low? The younger brother is bored to death, no problem with the wire drawing machine, the full load will jump off. Display frequency converter overload and acceleration operation overcurrent. Help me please.
The difference between the display value and the measured value shows that the bus detection circuit is abnormal if the deviation is larger. Conversely, if the two value deviation is minimal or equal, the missing phase signal is abnormal. At present, there are two kinds of bus detection circuit used in our company: resistance voltage divider and operation comparison amplification (TL082). Corresponding to the detection circuit output 0 - 3.3V corresponds to the actual bus 0 - 1000V, the two circuits are relatively simple, maintenance only need to test the key point voltage in the circuit, you can easily find the fault point.
Q: I would like to ask, the inverter in use in the grid is very high?
Yes, because the harmonic generated by converter works has certain influence on the quality of power grid, so the demand for power grid is higher. Frequency converter (Variable-frequency, Drive, VFD) is the application of frequency conversion technology and microelectronics technology, by changing the power supply frequency of the motor to control AC motor power control equipment. The frequency converter adjusts the voltage and frequency of the output power by the breaking of the internal IGBT. According to the actual needs of the motor, it provides the required power supply voltage, and then achieves the purpose of energy saving and speed regulation,
Q: What are the basis of the frequency converter to choose?
1, brand, mainly for cost control2, performance, overload, function, reliability,3, load characteristics, constant torque, square torque or special load (determine the length of the cable of the load motor)4, environmental aspects: temperature, humidity. Altitude.These are the needs of attention when type selection.The last point is the most important, when choosing type, remember that the motor power can not be selected, must be selected in accordance with the motor current.

Send your message to us