• Cross-linked Polyethylene (XLPE) Insulated Shipboard/Marine Power Cable System 1
  • Cross-linked Polyethylene (XLPE) Insulated Shipboard/Marine Power Cable System 2
Cross-linked Polyethylene (XLPE) Insulated Shipboard/Marine Power Cable

Cross-linked Polyethylene (XLPE) Insulated Shipboard/Marine Power Cable

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT or LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Cross-linked Polyethylene (XLPE) Insulated Shipboard/Marine Power Cable

   XLPE  insulated low-smoke, halogen-free and flame retardant shipboard power cable,  type SC
   XLPE  insulated fire resistance and flame retardant shipboard power cable, type SNA,  SNC

 

Application:
 The XLPE  insulated shipboard/marine power cable with rated voltage up to and including  0.6/1kV is applicable for all kinds of shipboards and over-water buildings like  petrol platform at sea.

 

Operation Properties:
 Rated  voltage of cable:0.6/1kV.
 Continuous  permissible operating temperature:  85℃.
 Min  bending radius under installation
 Metal  braid armored type:6D;
 Non-armored  type:4D≤25
 6D>25

 

Execution Standard:


     Type

   Execution    Standard

DA Type

SA Type

SC Type

SNA Type

SNC Type

 

CJV/SA/DA/SNA
         CJV80/SA/DA/SNA
         CJV90/SA/DA/SNA
         CJV82/SA/DA/SNA
         CJV92/SA/DA/SNA

 

IEC60092-351
         IEC60092-353
         IEC60092-359
         IEC60228
         IEC60332-1
         GB9331.5

 

IEC60092-351
         IEC60092-353
         IEC60092-359
         IEC60228
         IEC60332-3
         GB9331.5

 

 

IEC60092-351
     IEC60092-353
     IEC60092-359
     IEC60228
     IEC60332-3
     IEC60331
     GB9331.5

 

 

 

CJPJ/SC/SNC
         CJPJ80/SC/SNC
         CJP90J/SC/SNC
         CJPJ82/SC/SNC
         CJPJ92/SC/SNC

 

 

 

 

 

IEC60092-351
         IEC60092-353
         IEC60092-359
         IEC60228
         IEC60332-3
         IEC61034
         IEC60754
         GB9331.5

 

 

IEC60092-351
     IEC60092-353
     IEC60092-359
     IEC60228
     IEC60332-3
     IEC61034
     IEC60331
     IEC60754
     GB9331.5

Specifications:


     Type (DA/SA/SB/SC/SNA)

No. of cores

Nominal cross-sectional area mm²

All Types

1

1—300

2

1—120

3

1—185

4—37

1—2.5

Type and Name:


     Type

Name

CJV/SA/DA/SNA

XLPE insulated PVC sheathed    shipboard power cable, type DA、SA、SNA

 

CJV80/SA/DA/SNA

XLPE insulated PVC inner sheathed bare tinned copper    braid armored shipboard power cable, type DA、SA、SNA

 

CJV82/SA/DA/SNA

XLPE insulated PVC inner sheathed tinned copper braid    armored and PVC outer sheathed shipboard power cable , type DA、SA、SNA

 

CJV90/SA/DA/SNA

XLPE insulated PVC inner sheathed bare zinc plated    steel wire braid armored shipboard power cable, type DA、SA、SNA

 

CJV92/SA/DA/SNA

XLPE insulated PVC inner sheathed zinc plated steel    wire braid armored and PVC outer sheathed shipboard power cable, type DA、SA、SNA

CJPJ/SC/SNC

XLPE insulated PO sheathed low-smoke, halogen-free    (LSOH) and flame-retardant shipboard power cable, type SC、SNC

 

CJPJ80/SC/SNC

XLPE insulated PO inner sheathed bare tinned copper    braid armored low-smoke, halogen-free (LSOH) and flame-retardant shipboard    power cable, type SC、SNC

 

CJPJ86/SC/SNC

XLPE insulated PO inner sheathed tinned copper braid    armored and PO outer sheathed low-smoke, halogen-free(LSOH) and    flame-retardant shipboard power cable, type SC、SNC

 

CJP90/SC/SNC

XLPE insulated PO inner sheathed bare zinc plated    steel wire braid armored low-smoke, halogen-free(LSOH) and flame-retardant    shipboard power cable, type SC、SNC

 

CJPJ96/SC/SNC

XLPE insulated PO inner sheathed zinc plated steel    wire braid armored and PO outer sheathed low-smoke ,halogen-free(LSOH) and    flame-retardant shipboard power cable, type SC、SNC

Main Technical Properties
   DC resistance and insulated resistance of  conductor
   The second class of Conductor


     
     Nominal
     cross-sectional area
     mm²

DC resistance of Conductor
     at 20℃ 
     ≤Ω/km

XLPE Insulation resistance ≥ MΩ/km

20℃

工作温度
     Operating temperature

1

18.2

1077

1.077

1.5

12.2

949

0.949

2.5

7.56

785

0.785

4

4.70

664

0.664

6

3.11

567

0.567

10

1.84

458

0.458

16

1.16

376

0.376

25

0.734

385

0.385

35

0.529

331

0.331

50

0.391

318

0.318

70

0.270

294

0.294

95

0.195

254

0.254

120

0.154

246

0.246

150

0.126

258

0.258

185

0.100

264

0.264

240

0.0762

246

0.246

300

0.0607

233

0.233

 

Main Technical Properties:


     No.

Technical Properties

Type DA

Type SA

Type SNA

Type SC

Type SNC

1

D.C. resistance of Conductor(Ω/km)

See above table

2

Insulation resistance(Ω/km)

See above table

3

Power frequency voltage test for 4h

Insulated    and no breakdown at 3.5kV

4

XLPE insulation hot set test

≤175%

5

Single vertical burning test

IEC60332-1

6

Bundled burning test


IEC60332-3(A type)

7
     7.1

Burning smoke density test
     Minimum light transmittance

 

 

 

 

60%

8

 

Fire resistance test



No breakdown for 90min at 750℃



9

Burning gas corrosion test


9.1

HCL Content (mg/g)

Not more than 5

9.2

PH value


Not less than 4.3

9.3

Conductibility (μs/mm)


Not more than 10

Referenced current carrying capacity for  continues operating

Referenced current carrying capacity for the  cable of single core and three cores


     Nominal cross-sectional area

    Referenced    current carrying capacity

Single Core

Three Cores

10

82

71

16

103

92

25

132

113

35

160

132

50

193

155

70

244

197

95

296

240

120

338

273

150

385

310

185

442

240

522

300

602

400

700

500

804

630

921

Temperature for continues operating

85℃

Surrounding temperature

45℃

Correction factors at different ambient air  temperatures:

 

the highest permission temperature for conductor

Correction factors at different ambient air temperature

35℃

40℃

45℃

50℃

55℃

60℃

65℃

70℃

75℃

80℃

85℃

60℃

1.29

1.15

1.0

0.82

65℃

1.22

1.12

1.0

0.87

0.71

70℃

1.18

1.10

1.0

0.89

0.77

0.63

75℃

1.15

1.08

1.0

0.91

0.82

0.71

0.58

80℃

1.13

1.07

1.0

0.93

0.85

0.76

0.65

0.53

85℃

1.12

1.06

1.0

0.94

0.87

0.79

0.71

0.61

0.50

90℃

1.12

1.06

1.0

0.94

0.88

0.82

0.74

0.67

0.68

0.47

95℃

1.10

1.05

1.0

0.95

0.89

0.84

0.77

0.71

0.63

0.55

0.45


Q:Cable yjv-0.6 / 1kv-4 * 120 + 1 * 70 What does it mean?
Cable trench as a power construction project should be cable trench construction construction design, cable trench construction program, according to the previous design requirements and programs in order to develop cable trench construction quality acceptance procedures
Q:The power cable for my DELL laptop AC adapter just got burned. I read the power that the desktop cable transmits. It is the same as my laptop's power cable. Is there a real risk if I use it?
Hi solomon, It is not recommended to use a desktop power cable for supplying power to laptop as it might cause damage to AC adapter as well as laptop. You may purchase a power supply cable at a nominal charge from a local electronics store. Thanks Regards, Sundeep B
Q:I have just bought the above SSD product and don't know what connection I need for power, I have a SATA cable but the other long slot doesn't fit any of my power adapters, what do I need?
You can use splitters.
Q:There are the six pins in the socket and six pins on the cable like on all other XBox i have seen. However a small black bit in-between the two rows of pins stop my cable going in at all. Not sure how what to do as the xbox is from Cash converters and it may be out of warranty. Thanks.
THAT CABLE YOU HAVE ARE FOR THE NEWER VERSIONS OF XBOX360 ....THE OLDER 360'S HAVE JUST THE PINS NO MIDDLE IF U BOUGHT IT USED YOU SHOULD JUST TELL EM TO EXCHANGE THE POWER CABLE OR BUY ANOTHER POWER CABLE FOR OLDER VERSION
Q:I have a cam camcorder battery charger power cable and I want to use it as a ps1 power cable. Is It possible. The both look the same.
The charger isn't meant to be a capacity source, purely a charging source. As such, with out battery, this is voltage will selection badly whilst a load is utilized and would land up adverse the stereo and/or the charger.
Q:Will this cable work with an iPhone 4s? On the website they only mention iPods, but I want to see if anyone has any experiences with this. It's a make-or-break deal for me. thanks
no offence but its a rip. go to walmart and buy an AUX cable they are 8 bucks and they will fit ipods phones and all that good stuff.
Q:I am trying to hook up a LCD display (CPU Temp, USB's in use, Memory Temp/usage, etc) and It came with a 5pin DIN connector for what I assume is the power. I am not sure what I need to do to connect it to the PSU. Any help or ideas?
I think this device should have a power connector as well as a sensor cable (USB in use should have a connector running on to your motherboard.) can you provide me the make/mode number of the equipment. Also provide me with a link so that i could see the connectors and wires and the device. Else take a pic, upload it some image hosting site and provide with a link. (you can edit your question or add additional info and provide a link. Replace the
Q:why power cables are to be earthed at both ends?
Its called the M.E.N. system. It stands for Multiple Earth Neutral. The neutral of an appliance acts as a return, held at a low potential by earthing at each house, using rods into the ground, transformers in the street with earths, and earth mats where required when soils are not conductive. When a fault occurs to earth the low earthing point causes the fuse / breaker to trip. GL
Q:Please i need help
u can find about your power supply cable . its hp parts direct store number.
Q:I have a ZXi8008 and there's a cable that goes out to the head unit to turn on the amplifier, which is different than the power cable. But in this car, i have not installed a new head unit. Where do I hook up this cable otherwise? It needs a constant power supply to be on.
i would hook it up to the power cable from ur stero that whay the amp will only come on when the radio comes on. that way u wont drain ur battery, thats if ur talking about the remote cable

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords