Black Wire 1.1mm 1.2mm 1.6mm 2.0mm 3.0mm 4.mm PVC Coated Copper Wire
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 25 m.t.
- Supply Capability:
- 25000000 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification
1.Structure of Black Wire 1.1mm 1.2mm 1.6mm 2.0mm 3.0mm 4.mm PVC Coated Copper Wire:
Black Annealed Iron Wire also called galvanized steel wire, galvanized iron wire according to the difference zinc coating process, there are electro galvanized iron wire and hot-dipped galvanized iron wire.
Black Annealed Iron Wire can be classified into hot-dipped galvanized iron wire and electro galvanized wire according to the differences of processing. This wire is very good for Chain link fence, fencing mesh, gabion mesh box production and for construction business as tire wire, binding wire and galvanized wire raw material production.
2.Main Features of Black Wire 1.1mm 1.2mm 1.6mm 2.0mm 3.0mm 4.mm PVC Coated Copper Wire:
• Use widely
• Corrosion- resistant
• Durable
• Practical use
• Beauty Surface
3. Black Annealed Wire Black Wire 1.1mm 1.2mm 1.6mm 2.0mm 3.0mm 4.mm PVC Coated Copper Wire Images
4 Black Wire 1.1mm 1.2mm 1.6mm 2.0mm 3.0mm 4.mm PVC Coated Copper Wire Specification:
Chemical composition | C | Mn | Si | S | P |
Guarantee value | ≤0.12 | 0.3~0.6 | ≤0.35 | ≤0.035 | ≤0.040 |
Test Item | Rm(MPa) | ReL(Mpa) | A(%) | KV2(J) | KV2(J) |
Guarantee value | ≥420 | ≥330 | ≥17 | -(normal temperature) | -(0°C) |
General result | 460~540 | ≥340 | 18~26 | 50~80 | ≥47 |
5.FAQ
We have organized several common questions for our clients,may help you sincerely:
①How about your Black Wire 1.1mm 1.2mm 1.6mm 2.0mm 3.0mm 4.mm PVC Coated Copper Wire?
We are focus on steel wire trading for more than ten years. We are specialized in export of various kinds of steel wire and wire mesh products, like Black Annealed Iron Wire we offer high quality steel wire; hot dipped wire; electro galvanized wire; PVC /PE coated wire; fencing , steel wire rope, steel wire strand, cable wire; wire mesh and other wire related products.
②What is the advantage of our Black Wire 1.1mm 1.2mm 1.6mm 2.0mm 3.0mm 4.mm PVC Coated Copper Wire?
1. Durable service life and competitive price.
2. Beautiful, strong and not expensive.
3. With long live and good anti-corrosive
4. High quality and low price.
③How long can we receive the product after purchase?
In the purchase of Black Annealed Iron Wire within three working days, We will arrange the factory delivery as soon as possible. The pacific time of receiving is related to the state and position of customers. Commonly 15 to 20 working days can be served.
Black Wire 1.1mm 1.2mm 1.6mm 2.0mm 3.0mm 4.mm PVC Coated Copper Wire
- Q: I want to make wire art but I'm not sure what type of wire to use
- They also sell rolls of other wire, click on metals in the top sequence, choose one then choose wire.
- Q: i hate the wired controllers. they all get tangled
- All DualShock2s are wired. However, a company named Katana made a wireless controller called the force2 that was of high enough quality that Sony made it an officially licenced product (as opposed to all the other third-party controllers) and allowed them to use the same physical design and packaging as the actual DualShock2s. It's a nice little controller, though it doesn't like rechargeable batteries at all.
- Q: What good would it do to change my spark plugs and wires would it be a good idea for a 86 year of a car they've never been changed before I was wondering would it help the car out thanks for the help
- you will find the car will respond better. You should car the sparkplugs once a year. The wires maybe every ten years or until they are not working.
- Q: what if I use a 100 amps.main braker to wire my range and dryer
- I'm not sure if you are asking if you can hook them both to a 100 amp breaker, or you want to wire them from a 100 amp sub-panel? A standard electric dryer is 30 amps and requires a 30 amp branch circuit using 10 gauge copper wire (10-3 with ground), and a standard electric range is 40 amps and requires a 40 amp branch circuit using 8 gauge copper wire (8-3 with ground). You need to hook them each to their own individual breaker.
- Q: i need to connect a new bathroom light/fan combo to existing wiring. Existing wiring is black/white/red/copper. The new fixture wiring is black/blue/white/white. Thanks
- The existing wiring should be as follows: Black and Red are both hot. White is neutral. Copper is ground. The fan/light fixture should be as follows: Black and Blue are hot for the light and fan separately. White and White are neutral for the light and fan separately. Connect all 3 white wires. Connect the two black wires. Connect the Red and Blue wires. Connect the copper to metal on the fixture. The only thing left is to determine which switch is the light and which is the fan.
- Q: I live in a condo and Im trying to wire a new light. When I wire it, it stays on constantly despite hitting the switch.The wiring Im dealing with is as follows.At the switch on the wall, there is a red wire, brown wire connected to the switch. A green wire connected to the box in the walll behind the switch.In the ceiling there is a brown wire, green wire, and a white wire wrapped with an unstripped red wire.Coming from the fixture are black, white, green.Ive tried connected black-brown, white-white green-green but the light stays on no matter what. Also tried white-brown, black-white, green to bolt. Still the same thing happens.Not sure what to do.
- the red and brown are probably positive (red) and the brown (neg) The green is probably a ground wire. You can go to the hardware store. Home Depot or Sears or Ace etc and get a small tester and then touch it to the wires. It will come with instructions and you can also ask the sales person in the electrical dept.
- Q: I have two kicker cvr 12s looking to wire them to an acoustic 601se amp can someone please tell me how to wire them like by matching the dots up and stuff.
- Wire okorder /.. . This will drop the ohms down to 2 ohms each and this way of wiring sound much better.
- Q: ok i have 3 questions...i have a oldsmobile cutlas supreme and i have a 0 gauge power wire that is 17 feet is that long enough???? and i have 0 gauge ground that is 17 feet is that long enough....and about the speaker wire..i have 8 gauge speaker wire that is 25 feet..is this a good setup.make sure u answer all these questions please thank you..
- 8-10 awg could be extra desirable than sufficient for floor. Make a sturdy floor... run it removed from any the +ve and speaker wires... and make confident the bare metallic on the physique artwork is advantageous and clean... this could make each and all the version as you may understand between stable sound and a relentless humming on your audio gadget... sixteen-22 awg for audio gadget reckoning on your determination and producer suggestions. IMHO the audio gadget purely desire a sign and the decrease gauge does not make a great difference. in certainty a speaker run on 4 awg can sound worse than an 8 awg... however the right way is to fulfill a million/2 way and characteristic sixteen-22 awg. The lighter twine additionally ability you shop cable weight.
- Q: how do you hook up a wired connection with xbox 360 if you have an wireless connection(the wire included with the 360)
- If you have a wireless connection it has to plug into a wired connection somewhere. I would just guess that you have a wireless router. There should be extra ports on your router for a wired connection(on the back of your router). You can buy a Linksys aftermarket wireless adapter for your 360 that will work on your wireless signal, or just buy the xbox version for $100. E-mail me if you have other questions, I am sure I can help if needed. I work for a communications company, and wireless and cabling is what I do all day long. If needed you can click on my profile and e-mail me from there.
- Q: im hooking up a air/fuel tomorrow and i need to know what color the wire for the sensor signal is on my rt... i have 4 wires and heres the colors and were they are from. t/w or o/t from c124 b/lbl from c14 and c315 b gound and o/dg from fuse a... need answer thanks
- It should be the BLK/ LB wire (although my wiring schematic shows that wire BLK/ GREEN), It will be the only circuit that have a varying voltage between 0-1 volt. Probe the wires with a DVOM and determine which wire has the signal, one wire will supply B+ for the heater, one is heater ground, one is reference supply voltage and one is signal return The signal return is the circuit you need to tap.
Send your message to us
Black Wire 1.1mm 1.2mm 1.6mm 2.0mm 3.0mm 4.mm PVC Coated Copper Wire
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 25 m.t.
- Supply Capability:
- 25000000 m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords