1.5mm 2.5mm 4mm 6mm Copper Wire/Electrical Wire and Cable

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100000 m
Supply Capability:
1000000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

Specifications

PVC sheath solid conductor electrical wire 
ISO 9001-2008 
Voltage: 450/750V 
Cross section:1.0mm2 to 500mm2 
OEM acceptance

 

Solid copper conductor 1.5mm 2.5mm 4mm 6mm electrical wire and cable

 

1.electrical wire is usually PVC insulated wire

PVC insulation no-sheathed general purpose electrical wire,single core,solid

2.sheathed round wires:

copper(aluminum)conductor pvc insulated pvc sheathed solid wires

copper(aluminum)conductor pvc insulated pvc sheathed flexible wires

Sizes:0.5-185mm2

3.products can be produced and provided accroding to standard G/T5023,IEC60227,BS6004,JB8734.

Standard:

GB/T5023.1-1997  450/750V or below PVC insulated electric wires.

GB/T5023.1-1997 is identical to IEC227,models are the same,can be produced according to customers requirement.

Using purpose:

4. used for AC rated voltage 450/750V and below for the followings:

lighting,electrical installation,the connection between instrumention and telecomunication equipment

 

Technical Data Sheet

Class 2 Conductor

Nominal
sectional area
mm2

Conductor
No/Dia.
mm

Nominal
Insulated thick
mm

Max overall
Dia.
mm

Condcutor
Resistance at
20

Weight
Kg/km

Cu

Al

Cu

Al

1.5

1/1.38

0.7

3.3

12.1

-

19.2

-

2.5

1/1.78

0.8

3.9

7.41

11.8

30.8

15.0

4

1/2.25

0.8

4.4

4.61

7.39

45.5

21.0

6

1/2.76

0.8

4.9

3.08

4.91

65.0

29.0

10

7/1.35

1.0

7.0

1.83

3.08

110.0

52.0

16

7/1.70

1.0

8.0

1.15

1.91

170.0

70.0

25

7/2.14

1.2

10.0

0.727

1.20

270.0

110.0

35

7/2.52

1.2

11.5

0.524

0.868

364.0

150.0

50

19/1.78

1.4

13.0

0.387

0.641

500.0

200.0

70

19/2.14

1.4

15.0

0.268

0.443

688.0

269.0

95

19/2.52

1.6

17.5

0.193

0.320

953.0

360.0

120

37/2.03

1.6

19.0

0.153

0.253

1168.0

449.0

150

37/2.25

1.8

21.0

0.124

0.206

1466.0

551.0

185

37/2.52

2.0

32.5

0.099

0.164

1808.0

668.0

 

 Class 5 Conductor

Nominal
sectional area
mm2

Conductor
No/Dia.
mm

Nominal
Insulated thick
mm

Max overall
Dia.
mm

Condcutor
Resistance at
20

Min insulated
resistance at
70MΩ/km

Weight
Kg/km

2.5

9/0.41

0.8

4.2

7.41

0.011

33.0

4

19/0.52

0.8

4.8

4.61

0.009

48.0

6

19/0.64

0.8

5.6

3.08

0.0084

68.0

10

49/0.52

1.0

7.6

1.83

0.0072

115.0

16

49/0.64

1.0

8.8

1.15

0.0062

176.0

25

98/0.58

1.2

11.0

0.727

0.0058

272.0

35

133/0.58

1.2

12.5

0.524

0.0052

384.0

50

133/0.68

1.4

16.5

0.387

0.0051

510.0

70

189/0.68

1.4

16.5

0.268

0.0045

714.0

95

259/0.68

1.

19.5

0.139

0.0035

965.0

120

259/0.76

1.8

22.0

0.153

0.0032

1210.0

150

259/0.85

1.8

25.0

0.124

0.0032

1510.0

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the difference between a kbg threading pipe and a PVC threading pipe?
May be charging head of the problem, the line may also be a problem. If the warranty can be free for the change.
Q:Home leaked, installed in the floor below the wire was blisters will have any security risks? How can the water inside the pipe to dry
Cable is a unified call, including power cables, communication cables, etc., I do not know what type of cable you need the type specifications. On the power cable in terms of the main models are: VV, BJV, VV. BJV. . ZR, NH and other models, as the specifications that too much.
Q:Automotive wiring harness welding to pay attention to what the problem
5 small cable, if you feel high cost Can be from the distribution box to the circuit The first light using a small cable low-voltage bus to the equipment side, due to the power distribution room to the equipment side will appear more climbing, bus installation climbing very troublesome and affect the beautiful, The bus outlet cabinet uses cables and installs the transfer box on the busbar
Q:Is there a difference between PE cable and PE water supply pipe?
The color is easy to distinguish. General yellow on behalf of the video line, red white plug left and right audio.
Q:2.5 square copper (green, with the threading tube) can withstand the highest power of several kilowatts,
Do not know why not mislead. The The The The The Fire resistance is IECGBBS6387. GB is the general principle of flame retardant and fire resistant wire and cable, quoted the above criteria...............
Q:Where should the inner diameter of the plastic tube of the cable be at least the number of times the outer diameter of the cable?
Not allowed to slot the proposal with PVC gusset which is only 1 cm thick only open protective layer on it! The water pipe is not enough unless you have a thickened wall outside the decoration.
Q:Building decoration wiring pipe elbow with yellow wax tube can you?
Indicating that your Apple data cable is not original, no effect, re-plug the general and you can use the.
Q:When pouring concrete is how to put the tube
Oh, the pipeline is poured before the layout according to the design drawings.
Q:What is the cable for rvv? Is it a power cable or a control cable? What is the cable?
The installation process is a certain requirement, high and low voltage cable bridge should be installed separately as usual, a wall laying vertical pipeline (slot) or installation equipment, the power distribution between the depth of D1 = 1200 ~ 1500mm; weak Between the deep distance from the D2 = 1100 ~ 1400mm more reasonable. The length L1 and L2 between the power distribution and the weak can be determined according to how much electrical equipment and pipelines (slots) are installed in the room. "Civil building electrical design specifications" proposed "shaft size in addition to meet the wiring spacing and terminal box, distribution box layout must be the size, but also in the box before the left not less than 0.8m operation, maintenance distance" requirements. In the weak equipment, the operation and maintenance distance is not specified in the provisions of the Code for Electrical Design of Civil Buildings, but it should not be less than 0.8m. Cable to wear steel pipe wiring, should be reserved in the floor steel pipe, wiring should be completed after the plug fire fire blocking material. Cable bridge installation should be horizontal, the maximum sag should not be greater than 10 mm; proposed separate installation
Q:What is the difference between "wire" and "cable"?
Simple point, the plotter is generally used to out of the line map, the general is the Academy of Engineering, the Bureau of the use of a CAD map, and some can also be some effect of the general effect of the map, generally suitable for color requirements are not very high, but right Print accuracy requires a high place. Inkjet machine can be divided into indoor and outdoor ink, outdoor irritating smell, for outdoor advertising like the effect of the map, the indoor no irritating smell, the general subway, as well as other indoor advertising are used this out of

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range