Air Grille for HVAC systerm And Air Conditioning

Ref Price:
Loading Port:
Payment Terms:
Min Order Qty:
500 pc
Supply Capability:
999999 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specification of Air Diffuser


Supplying Air Diffusers 
-Frame Thickness: 1.0mm /0.8mm
-Any Size be customed 
-Powder Coated RAL 9010/9016



HVAC aluminum air conditioner grille



Extruded Aluminum alloy (6063-T5)



Blades in 45°from aluminum profile or as customer’s requirements


Bar spacing

30mm as standard or as customer’s requirements



0.8mm, 1.0mm, 1.2mm, 1.5mm or according to the customers’ 


Surface Finish

Powder coated, Anodized , PVDF, Mill finish.



Width x Height, any sizes available


Powder for Finish

Environmental protection and non-toxic, and Color to keep 5 -10 years.



Refer to RAL colors swatch or customized colors available



Drawings designed according to the customers’ requirements


Payment terms

T/T, L/C, PYAPAL, etc.


Delivery time

Usual 15-20 work days for a 40GP container 


Package details

Bubble wrap + Cartons for FCL,  Bubble wrap + Cartons + Wood-box for 



Stainless steel security mesh, Aluminum security mesh



Fixing and adjustable installation

Usage of Air Diffuser


The grille is suitable for ceilling  sidewall, soffit or cill mounting and may be used for supply or extract applications. 

Typical installations include offices, shops, hotels and most commercial or industrial buildings.

Available as standard in white polyester powder coat finish. 

Other polyester powder  coat finishes are also available as an option.


Air Grille for HVAC systerm And Air Conditioning

Air Grille for HVAC systerm And Air Conditioning

Air Grille for HVAC systerm And Air Conditioning

Air Grille for HVAC systerm And Air Conditioning

Air Grille for HVAC systerm And Air Conditioning

Air Grille for HVAC systerm And Air Conditioning


FAQ of Air Diffuser:


1, What's size do u have for round type diffuser?

A: We have face size from 150mm to 550mm,neck size from 250mm to 400mm


2, Do u still have other types ?

A: Yes, we have round diffuser/ rectangle diffuser/ linear grilles/ baseboard diffusers,etc


3, What's the most early delivery time?

A: Within 25 days for each 40'fcl


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Carbon crystal wall warm how good carbon crystal wall warm advantages and disadvantages
Carbon crystal wall warm how good carbon crystal wall warm advantages and disadvantages
Q:Geothermal coil spacing is too hot not how to do
Home improvement 200. works 350...
Q:How to reduce the energy consumption of electric boilers?
To prevent the valve within the leakage insulation to meet the specifications required to clean the boiler in time for a long time without power failure
Q:How to solve the heat pipe plug?
Plumbing heat pipe after 2-3 years, the tube wall will produce a lot of accumulated dirt, resulting in inadequate water flow, heat is not enough, heating effect caused a great impact, this time you need to use the warm pipe cleaning equipment to solve the warm pipe Blocking the problem, to warm the pipe dredge commonly used tool is to warm the pipeline dredge machine. In order to clean the pipe, it is necessary to use the correct way to clean, otherwise it will cause unnecessary results.
Q:How to use the boiler to open a few files
To warm the boiler to 2-3 files can be. To the use of the boiler: 1, the pressure in the use of the boiler should not be set too high in use, the pressure of the boiler must not be set too high, usually maintained at 1.2-1.5MPa is the right, if the pressure is too large, It will damage the life of the sealing parts, when the pressure is too small will occur the system can not run the normal work, adjust the pressure inside the boiler, as long as the open through the leak valve, the water, in the water on it. 2, do not mix hot water and cold water in daily life, the majority of users are often hot water mixed with cold water use, which is no problem in the water heater, but if the use of warm to the boiler will cause some bad consequences , This is mainly because the warm water boiler is not a direct heating, and only after adding cold water will lead to the cycle to change the pressure inside the system, the boiler sensor will often re-set the system heating mode function, Will cause the boiler to re-use, this will accelerate the aging rate of the boiler. 3, the boiler cleaning and maintenance problems At the end of the day, usually we need to warm the maintenance will be cleaned, the user can operate the first switch into the water, and then increase the pressure to 2, open the drain valve, dirty The water will automatically flow out, so repeatedly operation again and again, until the outflow of water is clean on it, and finally should also open the inlet valve and drain valve, after rinsing, clean, must To add clean water, then adjust the pressure to 1.2-1.5MPa on it.
Q:What kind of equipment is the protection of the fan coil in the ground source heat pump?
Ground source heat pump systems are durable and highly reliable. Contains less mechanical parts, and all mechanical parts are not buried in the ground is installed inside the house, which makes the equipment from external damage. Underground buried pipeline has 50 years of service life. Ground source heat pump system is very quiet, so that the environment inside and outside the house are very pleasant. Ground source heat pump system is no noisy fan equipment, whether in the courtyard or near the courtyard, will not affect the outdoor activities. Ground source heat pump system is safe and reliable. Since no instruments are exposed to the outdoors, children or pets are protected from damage and damage to external equipment. Ground source heat pump systems do not have open flames, flammable fuels or potentially hazardous fuel storage tanks. Plumbing geothermal is closed through the water under the floor of the cycle to the temperature of hot water to increase the temperature of the indoor temperature, do not close the doors and windows, and the head of hot head in line with human health, the body is very comfortable.
Q:Home coal-fired heating stove and electric heating furnace which is good
Coal, cheap to save money. Electricity, clean and easy to control, expensive
Q:What is the role of heating water tank?
The role of heating water tank to provide living water, to provide life heating
Q:The working principle of the heat transfer station
A heat source through the pipeline to the heat transfer station, and into the heat exchanger, heat exchanger through the heat exchanger, the primary heat exchange to the secondary heating pipe, the secondary heating pipe leads to hot users.
Q:What is the air source heat pump to warm air conditioning two for the system
Hello, are you trying to heat and cool the equipment? At present, a multi-functional heat pump called triple supply, refrigeration, heating, hot water three functions of the unit. In the cooling mode, you can get free hot water of life, energy efficiency is very high, heating mode can do floor heating, radiator, hot water and so on.

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range