• 26inch sand gravel pump with High Quality System 1
26inch sand gravel pump with High Quality

26inch sand gravel pump with High Quality

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
1 unit
Supply Capability:
100 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Our gravel pumps are manufactured to be the best standards, ensuring longer service life, higher performance, ease of operation and maintenance. The pumps are widely used in mining, construction, metallurgy, power plant, sewage water treatment, dredging, and chemical and petroleum industries.

Function Introduction:
1. Horizontal cantilevered single-casing centrifugal gravel pump.
2. Pump discharge direction in any of 360. Easy installation.
3. Cylinder bearing assembly, oil lubrication, adjusting the distance between impeller and pump.

4. Mechanical seal, expeller seal and packing seal
5. Wide passage, good performance of NPSH, anti-wearing and anti-corrosion, high efficiency,
6. V belt driver, gearbox driver, elastic coupling driver, fluid couplings driver, frequency conversion driver, silicon controlled rectifier speed regulation etc.

 

Capacity (m³)Head (m)Speed (r/min)Inlet (mm)Outlet (mm)
3.6-12095-99.4350-380038-25425-203

 

Q:What's the water pump?
A water pump that automatically or manually supplies water to the water system when the amount of water in the water system decreases (evaporation, overflow, etc.), and does not belong to a chilled water pump or a cooling water pump.
Q:When I turn on my pump for the pool water-fountain it will run for 30 seconds or 4 minutes or anywhere in between then it just shuts off. I push the remote on button on again and it runs for a few seconds. Sometimes it will run for a while longer but mostly short durations. Thanks in advance for your help.
Contrary to another poster's reply, if it were an electrical problem and there was a larger than acceptable load (draw) on the electrical system, the breaker switch would click off as the amperage from the pump or wiring would create too great a draw. That is what breaker switches are for. It is likely that you have a vacuum leak or something plugging a line. Check the filter basket ... check the pool water return lines from the pool to the pump. Bleed air out of the filter. If those don't work, it would be time to call a pool service.
Q:i have a 1994 honda accord lx. i was wondering what the water pump is for and if it goes bad can i still drive around without it thanks
1994 Honda Accord Water Pump
Q:300M head of 11 stage centrifugal pump with 22KW motor, empty (not water) current of 13A, the water into the pump, current up to 44A, open the outlet valve of the current rising to 100A, immediately shut the gate current is up to 170A, the motor stop. Without any problems, not on the impeller pump shaft is not clean the shell the balance sheet, no wear, bearing normal.
(1) the influence of the basic installation on the equipment.The quality of equipment foundation installation has great influence on the quality of equipment operation. Iron pad placed properly, causing around the foot bolt hanging device, in alignment and fastening process for iron pad hanging, tighten anchor bolts will cause deformation of crosshead slide in the crankcase, the cross head is blocked in the operation of reciprocating load increases when the chute.W5 type reciprocating vacuum pump in the structural design of the cylinder body is cylinder, and the piston, intake and exhaust valve after the heavy weight in the foundation design without considering the cylinder support or hanger, the cylinder will be in a suspended state, because the weight of the crankcase cylinder will cause deformation of the cylinder and slide and slide the concentric degree of difference, so that the cross head is blocked in the slideway and the piston reciprocating operation is blocked during the reciprocating motion in the cylinder caused by the increase of the load.According to the above analysis, inspection found that the vacuum pump end of the cylinder body is slightly lower than the end of the crankcase, cylinder pad iron is low, deformation of crosshead guide foot bolts, the cross head caused by load increases in the slideway and the piston in the cylinder reciprocating operation is blocked, this is one of the reasons causing motor overheating.(2) cylinder and valve coking;The influence of process, cylinder and valve of reciprocating pump is easy to coke, Coke will cause the piston cylinder and piston in reciprocating cylinder operation when the load increases the valve is blocked; coking will cause poor exhaust, the valve closed lax, increasing load, low vacuum degree; clearance at the cylinder piston striking the cylinder will cause coke it will increase the load of cylinder, valve has found the phenomenon of coking, which is mainly caused by the low degree of vacuum.
Q:I would like to use water from the lake to water my lawn. My lawn is about 100 feet up hill from lake. Just want something I can attach a garden hose to. what type of pump and horsepower do I need.
Get an Aeromotor!!! You''re going to need 2 filters. One out in the pond you're pulling from and 1 filter prior to the pump. AlgeaQueen makes a good filter for out in the water.
Q:I have a 1998 ford taurus. It started to over heat so i turned on the heater full blast and it didn't get hot. so i put antifreeze in it and i turned it on and it seemed ok but it started to over heat again and the tank for the antifreeze looked like the cap was going to pop off. I was just down the road from my house so i thought if i drove slow i could make it home and it turned on ok but when i put it in drive it stalled. Does this mean its the water pump??????
This is bad news. For some reason, you ran low on antifreeze. It may have been your water pump or a hose leaking that caused it. Here's the problem now. More than likely a head gasket is leaking, or a head is cracked. Either way this is a big job and should be diagnosed properly first. Sorry. Good Luck!
Q:the impeller on my calpump pw1200 water pump will not turn. what is the problem? and how do you fix it
CLR soak. Remove the calcium and lime from the tap water use. I would use a 50/50 solution in the inlet and give it 30 min then plug it back in with the in and out in a bucket with the 50/50 mix until it runs like new.
Q:What is the difference between a sewage pump and a clean water pump? Why can't sewage be pumped with clean water?
The main difference between water pump and sewage pump is that:Impeller and runner design, as well as other parts of the configuration are very different.1., in order to prevent clogging of sewage pump, the main design of large flow channel, so naturally lead to relatively low efficiency, so the head is generally not high. Clear water pump flow smaller, smaller clearance, the head is relatively high.2. in order to prevent the wound, water pump impeller design is more simple but not ring pump, equipped with tips, cloth and other debris can be crushed after the pump, and the impeller water pump is relatively complex, but the efficiency will be significantly higher than the former.Why can't the sewage water pump and impeller: because features of key design, resulting in water pump for sewage situation is likely to occur, blocking, winding, wear and corrosion occurs, resulting in damage to pump or scrapped, so water pump can not be used for sewage.Sewage pump is a pump and motor conjoined, and at the same time submerged into the work of pump products, and general horizontal pump or vertical sewage pump compared to the sewage pump compact structure, small footprint.The water pump is for the transport of water and physical and chemical properties similar to water and other liquids used, suitable for the industry and the city water supply and drainage, water pressure high-rise buildings, garden sprinkler, fire booster, long-distance transportation, HVAC refrigeration cycle, irrigation, bathroom, cold and hot water circulation pressurization and equipment.
Q:From the days of the laying of pipe line and trouble is far away, two or more people share the idea of a water pump, controlled by the electromagnetic valve, do not know whether it is feasible, attention should be paid to each of the power may be different phase, and it is the automatic control, automatic switching request all big brother big sister what the solution of power. At the same time, the electromagnetic valve is closed to others. Turn on your own solenoid valve StopThe idea is that each pumping with its own power, so you don't have to worry about sharing electricity.
If you want to share the electricity bill, but also to pay their own, but it is difficult ~ but we can change the way ~!First of all, we use a pressure tank or a water tower to let it water automaticallyAn electric meter is installed on the water pump to measure its total power consumption ~!Then each household installed water meters independently and measured their water consumption ~!Then, according to the amount of water consumption, according to their respective proportion of electricity charges ~ but this cost is higher ~!
Q:I received a call from my daughter who said that the water pump was making a grinding noise. She sent a photo to me showing 0 psi on the gauge. I came home to find it actually working again but after running water straight from the pump I found that it is really rusty. What is this caused from? Our water was nice and clear! We've had freezing conditions here. Still doesn't explain the sudden rust.
it relatively is probably not appropriate. a threat that the sump pump and the nicely pump have been tied jointly and has a GFCI breaker interior the line. See in case you will discover a GFI it relatively is likewise tripped.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords