XBD-W Horizontal Single-stage Fire-fighting Pump

Product Introduction:
   The XBD-W horizontal type single stage single suction fire extinguishing pump group, not is similar for the transportation including solid particle′s clear water and the physico-chemical properties to water liquid, mainly uses in the fire prevention system pipeline turbo-charged supplying water, also suitably gives draining water in the industry and the city, the high-rise construction turbo-charged supplies water, the long-distance range to supply water, the heating, the bathroom, the boiler changes in temperature water cycle, the turbo-charged air conditioning refrigeration system to supply water and the equipment necessary and so on situations. this department produces XBD-W fire extinguishing pump group its performance, the engineering factor conform to national new promulgation GB6245-1998 "Fire extinguishing pump Performance requirement And Testing method" the standard request, the product examine the central test after the national fire prevention equipment quality surveillance to be qualified, obtain the Shanghai fire prevention product approval certificate.
Range of Application :
 Water supply for hydrants and sprinkling, pressure stabilization of fire fighting system,and other locations to handle clean liquids.
Type Designation:
XBD 3.2/5-65W-160A
XBD – Fire Pump code
3.2 –Designed pressure (1/10MPa)
5 – Designed flow (L/S)
65 – Diameter of the pump outlet and inlet (mm)
W – Horizontal structure
160 – Nominal diameter of impeller (mm)
A – Primary cutting of the impeller
Technology Parameters:
Flow:5-100L/S;
Pressure:0.10-1.25Mpa;
Power:1.1-250KW;
Rotary speed:980-2900r/min;
Calibre:50-300mm;
Temperture range:≤80℃


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Fire pump room is required to set up water pump control room?
What is the concept of fire pump control room? If there is a control room host automatic alarm automatic fire alarm system of words (through the pump distribution box can also control) can control the fire pump, if there is no distribution box automatic alarm system you can through the pump room control
Q:Can centrifugal pumps be idle? What's the status of the empty transfers?
It burns and seals when idling. The individual thinks that it can be indirectly reacted according to the pressure change in the pipeline, and the electric contact pressure gauge can be installed on the suction pipe
Q:How to install circulating water pump for cooling tower?
I think it should be installed on the outlet pipe of the cooling tower
Q:Fire pump control cabinet installation distance, ground height should be how much?
The ground height shall be determined according to the height of the connecting line at the bottom of the control cabinet and the water pump, usually 15~20CM.
Q:Why can't sprinkler system and hydrant system share water pump in fire fighting system?
Code for design of sprinkler systems, GB, 50084 - 2001 (2005 Edition)The water pump 10. 2.1 systems should be set up independently, and should be a preparation or a preparation will set the standby pump ratio.10., 2.2, according to the two load power supply construction, it is appropriate to use diesel pump as a standby pump.Some of them used to be common pumps, and now the code emphasizes independence.
Q:What's the water pump?
Whether frozen water pump or cooling water pump, including the boiler with the water pump, as long as it is used for replenishment, are called water pump. Normally, the pump works intermittently.
Q:What is the 10KV pump unit?
10KV should refer to the motor start voltage value, ultra high voltage start, the general pump more than 160KW of the motor, the voltage used in 6KV, you motor should be more than 300KW
Q:The flow of the pump will be reduced, the speed will change, the power of the motor will change?
1, this pump flow reduction is not the reason for speed. Because it is not matching the motor frequency conversion, the frequency of power supply unchanged, the motor speed will not change.2, the flow of water pump down, the reason may be that the impeller due to cavitation or wear and tear smaller, second, the gap between the impeller housing change, and the impeller plug foreign bodies, and some of the suction port leak.3, it is possible that the whole system resistance increases, so that the work point of the pump left.
Q:Safety head of water pump?
In fact, to prevent pipeline errors, generally take 0.5 meters margin, just in case the pipeline changes, resistance, and do not smoke Sheung Shui
Q:37KW how many contactors does the pump need to start directly?
37KW current is about 70 a few A, you can use CJ12-100 contactor, the answer is for reference only, the premise is that the motor limit voltage is 380V.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range