Deep Well Pump 6SS(m) 6"

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The diving pump in the aquarium stops and stops on the goldfish
Submersible pump is used as if you push the pump filtration should be open for 24 hours, so the water circulation process, continuously into the fresh air to increase the oxygen content of water bodies two, filter on the filter of the continuous cleaning system to maintain water make nitrification safe and clean, the water can be fully introduced the content of nitrification ammonia water, let the fish live healthy and strong resistance, good activity, three appropriate water flow on the long time to keep fish, turn off and the formation of water to fish is always in a state of tension and decreased immunity antifeedant or death. Four, frequently start the pump, easy to cause damage to the motor coil, reduce pump life, so according to the above, if you are using submersible pump as a filter to promote, I suggest you open 24 hours.
Q:Why is the water pump smaller than the pipe diameter?
The size is only a matter of convenience or experience, and a small number of tubes are already available. As long as you can pick it up, you can use it.The so-called thick pipe to reduce resistance is a certain relationship. But it shouldn't be your decision to choose the big one. Then why don't you choose the big three? Four or the thicker ones?! @! The resistance will be smaller!!!!- - - - - - - - - - - - - - layman; look at the knowledge of fluid mechanics!!!The question is a conclusion, explain why not one or two words, learn the knowledge of fluid mechanics to know why -- try to answer it, that is to improve the water pump outlet total pressure head, intuitive feeling is to have enough pressure to pump out the water pressure. As for the big three or four, it is necessary to ensure that the flow velocity in the pipe is more uniform, otherwise the flow near the pipe wall will flow or flow too slowly due to viscous action.
Q:Water pump part is stainless steel, which part is it?
Of any part of the body that is in contact with water
Q:Diving pump voltage
Absolutely not, because 220V is not the same as the 380V waveform. Submersible pump single-phase motor is generally single-phase capacitor motor. The working principle is different from that of the single-phase 380 motor. If the power capacity is enough, it is recommended that you increase the wire (you can buy a line and go to use, to avoid waste), preferably with copper wire.
Q:How many kinds of pumps are there? What are the advantages of soft start?
The starting modes of water pump are direct start, star triangle start, reactance start, soft start, step-down start and frequency conversion start.1, direct start, generally suitable for small power motors, generally only in the following 15kw pumps, cheap;2, the buck start is the star triangle conversion start, that is, the start is accelerated two times to reach the rated speed, generally in more than 18.5kw pump use, moderate price;3, soft start is gradually increased to the rated speed, the impact on the pump is very small, the price is relatively high, is generally 3 times the buck start;4, the highest frequency conversion is started, in addition to the advantages of soft start, but also can be set at any speed work, energy saving has significant effect.Advantages of soft start:1, the output torque of the motor can meet the requirements of the starting torque of the mechanical system, ensure smooth acceleration, smooth transition, and avoid the impact of destructive torque;2, the starting current to meet the requirements of the motor capacity, to avoid motor heating, causing insulation damage or burnout;3, make the starting current to meet the grid power quality related standards requirements, reduce voltage sag amplitude, reduce the higher harmonic content.
Q:What are the new regulations in the design of main and auxiliary water bin and water pump room in coal mine?
The main water bin must have a main bin and an auxiliary warehouse. When a sump is cleaned, another water tank can be used normally.When the normal water inflow is below 1000m3/h, the effective capacity of the main water tank should be able to accommodate the normal discharge of 8h.The effective capacity of the main water bin can be calculated by pressing type in the mine where the normal water inflow is greater than 1000m3/h:V = 2 (Q+3000)Effective capacity of V-- main water bin in type m3;Q-- mine hourly normal water inflow, m3.However, the total effective capacity of the main water storage tanks shall not be less than the normal water inflow of 4h.The effective capacity of the water tank in the mining area shall be able to accommodate the normal water inflow in the 4H mining area.There is a big difference between the maximum water inflow and the normal water inflow in the mine. The drainage capacity and the water storage capacity should be specially designed.The water inlet chamber should be set up. A sedimentation tank shall be provided for the filling of water sand, hydraulic coal mining and other gushing water with a large amount of impurities. The water storage capacity of short positions must often remain above 50% of total capacity.
Q:Water pump is not Sheung reason
The problem you are experiencing is stressThe above answer is only considered in the case of water absorptionJust imagine, two pumps are normal work, the same suction pipe, how can there be dissatisfaction with water or vacuum state?.According to my experience analysisYour system is three sets of parallel, lift and flow should be the same, if not the same, not in this discussion, the topic should be set up.Lift is the same, that is, in two or three units at the same time, the resulting system pressurization is the same, and water will increaseBut now your traffic is increasing at two units, but it will not increase at threeYou have selected pipeline system design, in the design of head flow under single condition is constant, if the increase in open water pump, the pressure is constant, increasing water content, according to the continuity equation Q = A X V, then the flow velocity in the tube will increase;But when the third pumps, 2Q becomes 3Q, normally velocity should be larger, but the Darcy formula shows that the velocity increases, extension resistance and local resistance will be increased, and the double square, so you can open third pumps for reasoning, when the resistance effect caused by the pipeline the increase of water flow in the pipeline can not be reused, the general formula of constant current, now the whole pipeline in turbulent stateThat is, third pumps to do the work in the water and pipe wall friction in the loss, and actually did not play a role in water supplyThe solution is to increase the flow rate by increasing the water supply pipeline
Q:What motor with Grundfos pumps
General Motors Malaysia gelanfu! Can also be optional!
Q:What does the lift of a pump mean?
Lift lift height = water raise height = total lift lift height + water = water is expressed in M by H (m)
Q:How many lift pumps should be used for 100 meters tall buildings?
35m lift around. HVAC pump lift is generally between 5~50m, the selection of the head is mainly to see the difference between water pressure. As head of 35m as an example, if the inlet height of 60m, so the theory of height =60+35=95m, if all pipe closed air conditioning water system, and resistance of the equipment for water is equal to the pressure difference is equal to the pump head to choose your height, and out of the water is the same, the resistance loss of lift all into the water. The calculated resistance loss is needed to pump lift. The resistance component (1) chiller resistance at 60-100kpa (2) water collector resistance in 120-200kpa (3) 20-50kpa (4) air terminal equipment body resistance is generally not less than 40kpa so 100m building the resistance calculation of estimated value = (1) 80kp+ (2) chiller resistance pipe, the collector resistance (140kpa+ 3) air terminal equipment 40kpa+ (4) body resistance 50kp=310kpa safety factor of 10% 320x1.1=341kpa H= P/ (head of pressure water density * acceleration of gravity g =352000/ (10m) X9.8 =34.8m fand) so we head for 35 meters

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range