• WGJ Long Distance Connecting Drum Gear Coupling System 1
WGJ Long Distance Connecting Drum Gear Coupling

WGJ Long Distance Connecting Drum Gear Coupling

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Piece pc
Supply Capability:
500 Pieces per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

WGJ Long Distance Connecting Drum Gear Coupling 

1. long distance connecting drum gear coupling

 

2. stell material and other material available

 

model

WGJ1

WGJ2

WGJ3

WGJ4

WGJ5

WGJ6

WGJ7

WGJ8

WGJ9

...

WGJ23

nominal torque

6.3

11.2

18

25

31.5

50

63

80

100

...

3150

rotational inertia

0.005

0.28

0.43

0.73

1.43

2.56

4.26

6.02

7.95

...

3150

Q: I was wonder if I could fold my electric blanket under my mattress? It's too big for my bed, and I can't let it hang over the sides because there are walls in the way. Could I fold it so that half is on top of the mattress, and half is under the mattress?
Of course! Couldn't care less about your birthday suit, it's a fire no modesty there!
Q: So right after the curved pipe that comes out of the muffler a piece of pipe, probably a little over a foot long rust off. The pipe itself wasn't that rusted just the ends of the piece that broke off. The front of the exhaust pipe is still secure and the curved section attached to the muffler seems secure as well. My father is good at fixing cars and is going to replace this section with another piece of pipe and fittings/clamps etc. Does this sound like an okay fix?
Did /watch?vqQHSJg2Exk0 And if you watch very closely you will notice some lightning in the middle of the video, so I think there is a connection.
Q: Apart from the air-conditioning, the high-pressure pipe is not tight enough. What shall I do?
Will affect the cooling effect, it is recommended to cut off the connector, and then use reaming device to expand after re installation. Charges will not be too high, dozens of blocks enough to be careful to be pit.
Q: Which one is better with a logitech camera?
ive had resin in one of my teeth for nine years now, i had in another two but my new dentist didnt liked it and changed it to silver amalgam. i put it yesterday and believe me i cant eat proprely anymore because last time the fork touched the amalgam it shocked me! it was the most awful pain ever and my teeth had never hurt before. I just hope my dentist can change it back to resin without damaging my teeth i hate her for this. oh did i mention the methalic taste? yes go for resin
Q: Has anybody any problems with their Iridium shields flaking? It seems that the mirrored finish and color are starting to flake off around the bottom edge and the tab you use to flip the shield up with. Ive only had the shield for a few months and have only been really caught in the rain once. I use the Motosport Cleaner and Polish to clean it. Any ideas would be most welcome. Thanks
The glue will only work for the intended piping system. A shark bite fitting will transition from PEX to CPVC to copper. It is a brass fitting, that pushes on to the end of any of these pipes, and once on, will hold leak free. If you need to remove the fitting, there is a small tool, that when used, will remove the fitting in order to access the system, or to reconnect a different type of pipe. There are now more companies bringing their version of these fittings, that can't be removed. Good luck!
Q: Started at about 2am, the smoke alarm would go off for about 5 seconds, just to wake everyone up. Now, it went off again, same deal, about 5 seconds. I checked the furnace, it was off since midnight last night. I am not experiencing any signs or symptoms of CO poisoning. I check on my dog every 30 minutes or so, he is alert and have perfect coordination. What does it mean, usually the alarm last a lot longer when we bake. All my smoke detectors are linked together, the house was built in 2004.
because normally you have to cut threads on the end to allow attaching fittings
Q: I have a water fire extinguisher that was made in 1981 and was last hydro tested in 1999. I know how to recharge it, I just want to know if it is safe to do so?
I'm just guessing that you are referring to drain, waste, and vent (DWV) piping which operates under little or no pressure. Normally, waste and drain piping is made up from slip nut connections to simplify access for routine maintenance. In my experience, teflon ferrules will positively seal joints with finger tightness (if the piping and ferrule are clean). Ferrules (nylon or other plastic) are used on PVC and brass waste and drain piping. Rubber is used in some fittings but the performance depends on the integrity of the slip nut rather than the pipe wall (usually it is inferior).
Q: I have a pathfinder with an annoying alarm. If I take ou the Horn fuse will the alarm stop going off. It is SOOO loud that people at work and in my apartment complex want to gag me and kill me - but don't want to pay 50 bucks to have it shut off. Or what fuse number would it be?? It was already there and i bought it used, so there's not a manual.Thanks for any feedback!!!
Answering for others who lost their notes: Operating system functions: All input/output functions of the computer are controlled by the operating system. The OS manage use of the computer system, control of printers and moderns. The OS interacts with your hardware including DVD drive ,printer,sound and multimedia and many more. it creates a user interface so humans can interact with the system. The OS acts as an interface which translate human language into computer language, and helps you understand what you are doing (for instance in a program) without being a programmer! The OS takes information that you put in (like from your keyboard and your mouse) and processes it to do what you want it to do. An OS makes sure that your information is kept safe and in order on the hardware; the hard disk on your computer.
Q: Need info to purchase the lock
T Always keep them updated and scan and remove them. Each program is able to find different ones the other can't, so it actually is helpful to have all 3.
Q: Will the alarm still go off
7018 isn't well suited for vertical-down root passes, due to it's heavy, sluggish, fast-freezing slag. The thick heavy slag tend to cause inclusions when trying to fill an open root gap on pipe. It's traditional to use 601/6011 for the root pass, because it performs far better for open roots, 7018 is used for the filler passes. It's also traditional to use TIG for the root which generally produces far better root quality than stick welding. the root pass is critical because the greatest stress is on the inside of the pipe. If welding is absolutely your only option the best quality will be had by TIG welding the root, instead of 6010/6011. I would strongly recommed TIG roots. It is quite difficult to get a consistent root pass on small pipes. With pipe welding quality prep work and accurate fit-up are extremely important. Furthermore for small pipes, using screw-on fittings will likely save you labor in the long run. Not to mention being probably the more reliable option. Using a pipe vice and a pipe threading tool takes less time and skill than properly done fitting and welding. You might also consider brazing with slip-on joints. Brazing is faster, easier, and generally less prone to leaks than welding.
We have established an excellent network with more than about 50 factories in this field. Our factories are specialized in different products in order to have a much deeper and more thorough knowledge of the market and be better prepared to cooperate with our customers.

1. Manufacturer Overview

Location Jiangsu,China (Mainland)
Year Established 2011
Annual Output Value
Main Markets South America
Eastern Asia
Western Europe
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port
Export Percentage 11% - 20%
No.of Employees in Trade Department
Language Spoken:
b) Factory Information
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches