Rated Voltage 6kV to 15kV Forinverter Main Circuit Flame-Retardant Power Cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 10000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Rated Voltage 6kV to 15kV Forinverter Main Circuit Flame-Retardant Power Cable
1. Application
This product is suitable for AC rated voltage 15KV and below frequency control system for power cables or electrical connections, the product has a strong impact resistance, voltage, pulse voltage inverter can withstand time, the cable has a good shielding performance, and effectively eliminate electromagnetic interference reduce the frequency conversion motor noise, to ensure stability of the system. Widely used in metallurgy, electric power, petrochemical and industries.
2. Type and Specification
Voltage | 3.6/6 kV、6/6 kV、6/10 kV、8.7/10kV、8.7/15kV |
Type | Z-BPYJVP12、Z-BPYJVP12-22、Z-BPYJVP2 |
Specifications(mm2) | 3 Core:25~300 |
Standard | Q/XLJ 0349 |
3. Using Features
① Rated voltage Uo/U 3.6/6kV 、6/6kV 、6/10kV、8.7/10kV、8.7/15kV.
② Long-term allowable working temperature of cable conductor is 90 ℃
③ When the short-circuit (The longest duration of no more than 5S) conductor maximum temperature does not exceed 250 ℃.
④ When the ambient temperature of cable laying should not below 0 ℃, the minimum bend radius of 12 times the cable diameter.
⑤ Cable has good shielding performance, may reduce the adverse effects of higher harmonics of the inverter output exist.
⑥ DC resistances of conductor comply with GB / T 3956.
⑦ Cable flame-retardant characteristics comply with the requirements GB / T 19666.
4. Picture of Structure
1、Conductor 2、Insulation 3、Filler 4、Tape 5、Copper wire shield 6、Copper tape shield 7、Inner sheath 8、Armor 9、Outer sheath
FAQ
Q: How’s your service?
A:1. Offer customers 24/7 service, whenever you need us, we are always here for you.
2. Immediate response. Your any inquiry will be replied within 24 hours.
3. Support small order quantity, for the first time cooperation customers, we can send you less quantity for trial order.
4. Support third party inspection company to inspect and check the quality and quantity before delivery.
- Q: NH-YJV-4 * 4 in NH-YJV-4 * 4 in power cable tube
- Because the AC operation will produce eddy current, will make the steel pipe and cable heat burned. Single core refers to only one conductor in an insulating layer. When the voltage exceeds 35kV, most of the single-core cable, its core and metal shield layer relationship can be seen as a transformer primary winding coil and the relationship between the core. When the single-core cable core through the current when there will be magnetic lines linked to aluminum or metal shielding layer, so that both ends of the induced voltage. Power safety regulations: 35kV and below the voltage level of the cable are used at both ends of the grounding method, which is because most of these cables are three-core cable, in normal operation, the current flow through the three core sum of zero, in the aluminum There is no flux chain outside the package or metal shield, so that there is essentially no induced voltage at both ends of the aluminum or metal shield, so there is no induced current flowing through the aluminum or metal shield after grounding at both ends. But when the voltage exceeds 35kV, most of the single-core cable, its core and metal shield layer relationship can be seen as a transformer primary winding coil and the relationship between the core. When the single-core cable core through the current when there will be magnetic lines linked to aluminum or metal shielding layer, so that both ends of the induced voltage.
- Q: Apparently my computer has a 300 watt power supply. I am wanting to purchase a new graphics card but apparently in order to get a better graphics card then my existing card, Geforce 8400, I need a larger power supply.What will I need to purchase to increase the power supply to 500 watt and is it really worth buying all this? I am thinking I might aswell save up a bit more and buy a new computer.Any help apprietiated, thank you.
- There's nothing you can buy to boost your existing power supply - you have to buy a complete new one. Luckily though power supplies are relatively cheap. You can find a 500w supply for around $30-60.
- Q: When I plug and unplug a power cable to the net in my home for let's say, 50.000 times a day, why doesn't my electricity-meter not count that power for the monthly electricity fee?When I unplug the cable the cable should still have some electricity flowing through it at the moment of unplugging. That electricity disappears very shortly after . But after unplugging it, it doesn't have any electricity anymore. So some electricity is lost right? How does this work?
- by electricity I assume you mean electrical energy. power is the rate at which electrical energy is consumed. Power is generated by the flow of electrical current across a potential difference. Let's use an analogy. A cable is like a water pipe. Current is like the flow of water in the pipe. Pressure is like potential difference (voltage). When there is a difference in pressure at the two ends of the pipe, water will flow through the pipe. The flow of water carries energy, because it can be used to spin a paddle wheel (motor), and the friction of the water against the pipe (electrical resistance) generates heat. I think your question is something to the effect of, if I suddenly remove the pressure difference across the pipe, won't there still be energy in the water flowing in the pipe, and isn't that energy wasted? Well, there's a difference between water and electrical current: the electron hardly weighs anything. There's very, very little energy stored in the motion of electrons in a wire. When the wire is disconnected, the electrons come to a stop almost immediately, and the amount of energy wasted is infinitesimal. I hope that sort of answers your question.
- Q: this 40gb ps3 has no power computer cord or hdmi cable and i would like to know how much money i would spend all in all with allt he stuff i need...
- It's okorder A friend at work suggested I check them out when I was looking for various video and audio cables for my computer and flat screen TV. You'd be surprised how great the prices are. Hope this helps! It seem you've already gotten a ton of great suggestions.
- Q: I bought a used DVD player that didn't come with a power cord or power cable.On the back of the DVD player, the power cable input looks like this:__________|_o__|__o__)So basically it looks like the power cable should have two wires with one side being flat and the other end being a half circle.What is the technical name for this power cord so I can easily find it if I go to Radio Shack?Thanks.
- Ask for a 6 ft AC power cord. They come in a few difference shapes so just describe what you did here. If it helps reference Radio Shack model/catalog number #61-2878. Good luck!
- Q: Can anyone tell me the best place to run the power cable for my amp from the battery through the firewall? (2000 Chevy Impala)
- Look for where the factory wire harness goes through. there's usually enough room to cut or drill a whole and pass your power wire through. If not, you'll have to make your own hole in a safe place.
- Q: i have pentium iii cpu.unexpectedly i disconnected my power cable from power button.the power cable consists four color(red,black,white,blue) and in my power button it has four(p1,p2,1,2) pins.i don't know which colour is opt with this pins uld you plz help me...
- Find out the make/model of your motherboard. Go to the motherboard manufacturer's website and download the user manual for your motherboard. In this manual there should be a page (or pages) illustrating where the various headers and connectors are on your motherboard.
- Q: Beginner cost, do not know how the calculation of power cable works, is directly from the drawings on the amount of it?
- Fire paint is esterified by epoxy resin plant acid, respectively, with iron oxide red, iron oxide black, zinc yellow and other pigments and physical paint grinding, and adding driers, to, butanol modulation
- Q: what is the easiest way to replace the power window cables on the motor in the passenger side of a '94 accord
- If you are referring to the electrical wires leading to the power window system, then you need to cut wires and splice new ones back into the system along with the plug at the end of the cable.
- Q: How to choose the type of street lamp cable specifications, anxious
- Depends on your number is not arranged in order, the general building room when the patch panel and the user board number is one to one correspondence
Send your message to us
Rated Voltage 6kV to 15kV Forinverter Main Circuit Flame-Retardant Power Cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 10000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords