• P-12 Self priming centrifugal Diesel Trailer Mounted Water Pumps System 1
  • P-12 Self priming centrifugal Diesel Trailer Mounted Water Pumps System 2
  • P-12 Self priming centrifugal Diesel Trailer Mounted Water Pumps System 3
P-12 Self priming centrifugal Diesel Trailer Mounted Water Pumps

P-12 Self priming centrifugal Diesel Trailer Mounted Water Pumps

Ref Price:
get latest price
Loading Port:
Ningbo
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
10 set/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

                            Products Introduction

Product Description

Main datas:

     Capacity( flow rate) :  100 ~ 1270 m3/h

     Head  :4~43 m

     Speed:650 ~ 1250 rpm

     Impeller diameter:457.2 mm

     Pump weight:998 kg /1066 kg

     Power:20 ~ 175 hp

Advantage :

     Big pump body pass 76.2mmsolid ,high suction head 7.6 m

     Convenient repair and clean (a person ten minutes)

     Removable cover plate ,replaceable wear plate

     OEM ,L/C ,TT ,O/A ,D/P,D/A and so on

     CE ,TUV .ISO

NAME:  P-12 Self priming centrifugal Diesel Trailer Mounted Water Pumps

Standard SelfPriming pump units are available for Solids Handling or Clear Liquid

service. Typical mounting configurations are Engine Driven for Skid or Trailer Mounted

packages and Frame Mounted Electric Driven. Pumps also are available in a variety of different metallurgies.

1) Main Character

1.Beautiful shape and fine structure,reliable performance.

2.With strong capacity of delf priming, no need to equip with flap valve.

3.Non-clog, and with powerful capacity of passing big solid..

4.The hole can make sure that stronger sewage can be cleaned quickly when pump is jammed.

5.The unique lubrication oil mechanical seal cavity makes the performance more reliable.

6.Special check valve structure can make the pump working quickly.

7. When working, the gas and liquid  works together .

8. Low rotary speed,reliable operation,long time usage, easy to maintenance.

9.Advanced pressure protector make pump the pump work safe.


2) Application Area

1. Municipal project,  sewage project, instruction project.

2.Uptown,hospital, hotel sewage transportation.

3.Classification of municipal sewage factory treatment and concentrate system engineering.

4. Factory and contaminated water delivery.


3) Industries Served

♦ Construction

♦ Industrial

♦ Municipal

♦ Agricultural

♦ Mining

♦ Dewatering

♦ Industrial Waste

♦ Sewage

♦ Oil Field

♦ Petrochemical

♦ Paper Mills

♦ Processing


4)Parameter


1.Inlet/Outlet2''(50mm), 3''(75mm), 4''(100mm), 6''(150mm), 8''(200mm), 10''(250mm), 12''(300mm)
2.Impeller Diameter158.74mm-457.2mm
3.Rotary Speed550RPM-2150 RPM
4.Flow Rates8m3/h-1275m3/h20GPM-5500GPM
5.Head6m-63m
6.Horsepower1HP-125HP
7.N.W92KG-998KG
8.G.W114KG-1066KG
9.Solid Passing20.63mm-76.2mm
10.MaterialCast Iron, ADI, CD4MCU, 316 SS, Alloy 20, C276.
11.Diesel DrivingWater cooled or air cooled
12.Method of ConnectionSelf-priming pumps are available as basic units or may be flex-coupled, V-belt driven or engine mounted.
13.Drive VariationCummins, Deutz, Ricardo, Perkins or Chinese Diesel, Electric Motor
14.Skid Mounted on Trailer2 or 4 wheels Trailer/Trailor,Cart
15.PackageExporting plywood case
16.CertificationCE , ISO9001:2008 ,TUV



5) Mounting Configuration

♦ Frame Mounted

Base Mounted Electric Driven

♦ Engine Driven SAE Mounted

♦ Engine Driven Skid or Trailer Packages

♦ Horizontal or Vertical V-Belt Driven



5) Mounting Configuration

Frame Mounted

Base Mounted Electric Driven

Engine Driven SAE Mounted

Engine Driven Skid or Trailer Packages

Horizontal or Vertical V-Belt Driven

Packaging & Shipping

 

Our Services

 Samply available: 7~10days.
Qty: 1pc, only pump head is provided.
Price: US$100~200
OEM is welcome
OEM expierence: more than 10 years.
Countries: Germany, U.S.A, Spain, Italy, United Kingdom etc
Warranty: the whole pump is guaranteed within 1 year, the pump's spare parts are guranteed for 3 months from the date of delivery.
For more information, please do not hesitate to contact me.

FAQ


The information should be including inquiry as following:
1.Pump's flow rate
2.Pump's Head (Pressure)
3.Driven Mode: By electric motor or diesel engine or bare shaft etc
4.Power and rotary speed
5.Suction lift for self priming pump
6.Temperature of liquid if you can provide
Upon the receipt of the pump's parameter, we can send our quotation to you within 24 hours.

Or the condition of pump station would be provided.

♦FAQ:

1.   Q: Can I know more about your products?

       

        A: Pls view our website: www.lanco.cc.

2. Q: What’s your MAQ of this item?

        A: 1~2PCS

3. Q: What is the lead time?

        A: 10~30 days after receiving your payment,depends on pumps.

4. Q: where is your loading port?

        A: Ningbo, China port

5. Q: Are you a manufacturer or trading company

        A: We are a manufacturer specialize in water pump and other pumps more than 20 years.

For more information, please contact me.


Q: What is a solution pump?
(4) smooth running, low noise, no lubrication, no lubrication and low noise due to the absence of rolling bearings and motor fans(5) a wide range of use, the high temperature, high pressure, low temperature, high melting point and other conditions are able to meet the requirements2.2 shielding pump shortcomings(1) because the shielding pump adopts sliding bearings and is lubricated by the medium to be transported, the medium with poor lubricity should not be transported by shielding pump. Generally, the viscosity of the pump medium is 0.20mPa.s.(2) the efficiency of shielding pump is usually lower than that of single end mechanical seal centrifugal pump, which is approximately equal to that of double end mechanical seal centrifugal pump(3) long time in small flow operation, shielding pump efficiency is low, will lead to heat, make the liquid evaporation, and cause the pump to dry, and thus damage the sliding bearingsCanned pumps can be divided into the following types: 1) basic type 2) reverse circulation type 3) high temperature type 4) high melting point type 5) high pressure type6) self priming 7) multi stage 8) mud type
Q: Variable flow pumps are variable pumps
Yes. The variable pump is designed to change the flow rate
Q: How to select metering pump head?
When it comes to metering pump heads, the usual problem is when they measure acid, chlorine, fluoride, and hydrogen peroxide. Due to the difference in concentration and operating temperature, it is difficult to determine the specific pump head material.
Q: What is the relationship between the minimum suction vacuum of a pump and the required cavitation?
When the pump is working, the liquid at the inlet of the impeller, due to a certain vacuum pressure will produce steam, the vaporization of the bubble in liquid particles under the impact of movement, the impeller and other metal surface erosion, thereby damaging the impeller and other metal
Q: Brief description of centrifugal pump on / off operation
(3) check whether the turning rotor is easy and flexible, check the pump body is clang or friction sound.(4) the protective cover is installed, and the shield contact.(5) clean the pump frame and do a good job of sanitation.(6) open the inlet valve, make the liquid full of pump body, open the vent valve, clean the air and close it. If the hot oil pump, it is not allowed to open the air valve exhaust, to prevent hot oil channeling spontaneous combustion, if there is a dedicated vent pipes and tanks, you can vent the pipe line air and cold oil.(7) the hot oil pump should be preheated slowly before starting. Especially in winter, the pump body and the pipe should be preheated at the same time, so that the temperature difference between the pump body and the conveying medium is below 50 centigrade.(8) the oil must be sufficiently dehydrated before being introduced into the oil pump.
Q: Water pump does not produce water, what are the reasons?
6. is the motor running in correct directions?.7. pump body failure, such as sliding off the leaves or too much gap between the mouth ring.
Q: Difference between pump and compressor
Working principle:The impeller is installed in the pump casing and is fastened on the pump shaft 3, and the pump shaft is directly driven by the motor. There is a liquid suction in the center of the pump shell, and 4 is connected with the suction pipe 5. The liquid through the bottom valve 6 and the suction tube into the pump.The liquid discharge port 8 on the pump housing is connected with the discharge pipe 9. Before the pump starts, the pump shell is filled with the liquid to be transported; after starting, the impeller is driven by the shaft to rotate at high speed, and the liquid between the blades must also rotate. Under the influence of centrifugal force, the liquid is thrown from the center of the impeller to the outer edge and obtains energy, and leaves the outer edge of the impeller at high speed to enter the volute pump shell.
Q: What is the difference between the ground pump and the pump in the commercial concrete?
Move back and forth; pour concrete into a certain area. After the filling is finished, the whole pump truck can be moved to another position quickly
Q: Does the control cabinet of the fire control pump need to be related to the fire control room?
Automatic sprinkler, which is mostly used in this device or high water tank, the whole set of equipment must meet the most unfavorable point (the farthest the highest point of water) water pressure of the faucet.
Q: What flowmeter is installed after the pneumatic diaphragm pump?
According to your entire pipeline system to flow meter ah!How about the pressure, the material, the digital float or what?You must be sure of the size of the flow

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches