JET Water Pump

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1.Introduction


JET pumps are with an automatic ejector system, widely used in domestic applications, gardens and supply water  



2. Construction


Pump Body: Cast Iron/Stainless Steel/Brass
Front Cover: Cast Iron/Cast Iron with brass insert / Aluminum


Impeller: Brass/Aluminum/PPO
Mechanical Seal: Carbon/Ceramic/Stainless Steel
Motor Housing: Alloy Aluminum

Shaft: Carbon Steel/Stainless Steel/High Frequency Wedding Shaft
Insulation: Class B / Class F
Protection: IP44 / IP54
Cooling: External Ventilation


With thermal overload protector in single phase motor


 



3. Operation Conditions


Suction head up to 9M


Liquid temperature up to 60C
Ambient temperature up to 40C
Max.Pressure:9Bar



4. Technical Data




TYPE

Power

Ampere

R.P.M

Q.Max

H.Max

S.Head

Pipe Dia

L X W X H

HP

KW

1~220V

(l/min)

(m)

(m)

(mm)

JET-60M

0.5

0.37

3

2850

40

38

9

1"*1"

420*210*220

JET-80M

0.75

0.55

3.6

2850

50

42

9

1"*1"

470*205*250

JET-100M

1

0.75

4.8

2850

60

48

9

1"*1"

470*205*250




Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the pump lift voltage? And how to suppress the pumping voltage rise?
[pump voltage] when braking, in the motor winding series resistance, motor equivalent to the generator, the energy will be converted to electric energy consumption in the series resistance. This method is widely used in all kinds of motor braking, and frequency conversion control is also used. From high to low (zero speed), then the electrical frequency changes quickly, but the rotor of the motor with the load (production machinery) mechanical inertia, could not stop quickly, resulting in the back EMF (EU voltage) motor is in the state of power,
Q:The distance from the pump button to the ground
A button is arranged on the surface of the fire hydrant button, and when the fire hydrant is started, the press button can be pressed directly, and the red starting indicator light of the fire hydrant button is on
Q:How to adjust the flow of piston pump?
The oil pan with oil liquid through the suction port and the piston cylinder; from 180 degrees to 360 degrees, the piston cylinder volume decreases, so the oil liquid in the pan with oil discharged from the outlet of the liquid. The pump works continuously as long as the drive shaft rotates.
Q:Double floor sewage pump circuit diagram of a small problem
Question 4 when you need backup, you need to switch the SA switch, but where you want it. For example, when the 1# pump is running and does not reach the high water level, the 2# pump will not operate. If SA is placed in the left position, 21 and 22 are connected, and the KT is electrically delayed, and the KAB action causes the 2# pump to function. After the KAB operation, the KT will be disconnected, restored to the ready state, and also convenient for KT to restart the power on time, and also avoid the time relay to work on a long-term basis.
Q:Common failure treatment of piston pump
1) overflow valve regulation is too high, overload after the pump2) the overflow valve spool is blocked, the central hole of the valve core is blocked or the overflow valve is blocked by a damping hole, and the overflow is not overflow3) pump outlet one-way valve installed or spool blocked and stuffy pump4) motor fault x091) adjust the relief valve pressure value2) repair valve boring3) overhaul check valve4) overhaul or replace the motor
Q:What are the conditions required for hydraulic pumps to complete oil absorption and compression?
There must be one or more sealing volumes, and the volume of work is variable;
Q:The difference between submersible pumps and centrifugal pumpsWhat's the difference between the two? What is applicable and what?
1. submersible pumpsA very wide range of water treatment tools. Unlike ordinary water pumps, it works underwater, while the pump works mostly on the ground.The working principle of submersible pumpBefore the pump is opened, the suction pipe and pump must be filled with liquid. Open the pump, the impeller rotating speed, which leaves the liquid together with the rotation under the action of centrifugal force, the left outside impeller injection, injection of the liquid in the pump shell gradually slow the spread of indoor speed, the pressure gradually increased, and then from the pump outlet, the outflow discharge tube. At this time, in the leaves at the center of the vacuum area of low pressure liquid was thrown to the surrounding formation there is no air and no liquid, liquid pool at the surface of the liquid under the action of atmospheric pressure, through the suction pipe into the pump, the liquid is continuously pumped up from the liquid pool is also continuously from the outflow discharge tube.Basic parameters of submersible pumpIncluding flow, lift, pump speed, matching power, rated current, efficiency, diameter and so onSubmersible pump main application and scope of applicationIncluding construction, construction, drainage, agricultural irrigation and drainage, industrial water recycling, urban and rural residents cited water supply, and even rescue, disaster relief and so on
Q:What are the basic technical parameters of the pump?
The effective power of pump and output power, with Pe said. It is the effective energy per unit time from the pump in conveying out liquid obtained in the pump. Because the lift refers to the effective energy, pump output unit of heavy liquid obtained from the pump so that the product of head and the mass flow rate and the acceleration of gravity. Is to obtain the output from the pump in unit time of liquid effective energy - efficient pump power: Pe= P gQH (W) = QH (W) - P - density of liquid pumping (kg/m3); severe gamma - pump for transporting liquid (N/m3) - Q (pump flow; m3/s; H) - pump head (m); G (m/s2). The acceleration of gravity P axle power and effective power Pe is the difference of power loss in the pump, the size of the pump efficiency to measure the efficiency of the pump. As the effective power and shaft power ratio, with ETA said. Selection of related pumps:
Q:Because the water pressure of the booster pump is not enough, it can not work automatically. It can only be operated by hand. It is inconvenient to use.
The worst case is that the pump is not automatic when it leaves the factory, and no one can say whose product is 100%.But there may be automatic control of this piece, not debugging (this depends on the specific product manual or manufacturer)
Q:Hydraulic pump displacement refers to the pump shaft what?
You can see the sign of your hydraulic pump. There will be a displacement **ml/r in the sign of the hydraulic pump (r stands for every turn, ML is milliliter)

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range