Galvanized Steel Wire For Pvc Coated Wire

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Hot Dip Galvanized Steel Wire

(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .

(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .

(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.

(4) Tensile Strength Range

Size (mm)

Tensile Strength (mpa)

0.15-1.60

290-550

0.65-1.60

400-550

1.61-6.00

400-1200

(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.

(6) Packing

Size (mm)

Coil Size

Spool Packing

Big Coil Packing

ID (mm)

OD (mm)

0.15-0.26

6 inch

1-14kg/spool

0.27-0.60

8 inch

1-100kg/spool

0.61-1.60

12/14/16 inch

1-100kg/spool

250-400

400-770

1.61-6.00

14-500kg/spool

450

800

508

840


(7) Zinc Coating

Meet GB/T 15393 standard.

Size (mm)

Weight of Zinc-Coating ( g/m2 )

A

AB

B

C

D

E

F

A1

B2

0.25

30

20

18

>0.25-0.40

30

25

20

>0.40-0.50

30

20

>0.50-0.60

35

20

>0.60-0.80

120

110

40

20

>0.80-1.00

150

130

45

25

>1.00-1.20

180

150

50

25

>1.20-1.40

200

160

50

25

>1.40-1.60

220

180

50

35

30

>1.60-1.80

220

180

70

40

30

>1.80-2.20

230

200

80

50

40

>2.20-2.50

240

210

80

55

40

>2.50-3.00

250

230

90

70

45

>3.00-4.00

270

250

100

85

60

30

>4.00-5.20

290

270

110

95

70

40

>5.20-6.00

290

270

245

110

100

80

50


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Will 8 Gauge wire support 50 amps?
8 okorder.com
Q:how do I wire chandelier into the ceiling?
alongside with james answer the wires interior the ceiling are(power, black or purple ) and the (independent is white) interior america of a. The lamp could desire to be (a million) black and (a million) white cord so connect the colours to a minimum of one yet another. black-black then white-white. If the lamp wires are brown and blue then it rather is ( black to brown) and the (white and blue) . the reason in the back of it particularly is the outer area of the bulb (threads) is independent and the middle connection is the flexibility
Q:Floodlight installation: what are these three wires?
Am guessing that the third wire is a ground wire. check the instructions that came with it to be sure.
Q:Help in grounding a two wire outlet?
better to spend eight dollars and replace it with a GFCI outlet. It will protect every outlet downstream of it if you can determine which one is first. use the labels on all protected outlets.
Q:2001 honda civic oxygen sensor wiring?
Keep in mind the sensor has a signal wire, a ground wire and a heater wire (or wires). Good luck!
Q:red wire,black wire,white wire,green wire, which is live?
THe black wire is hot (live) The white wire is netural (return path) The green wire is ground (connected to metal juction box) the red wire is use in connecting three-way switch
Q:Whats the difference between 8 gauge wire?
properly, there are transformations in conductivity in wires of a similar gauge, based upon the fabric of which the twine is made and no count if or no longer it quite is multi-strand or good middle. That sounds like an quite huge hollow even even with the shown fact that. To account for that lots variance i could almost ought to think of the decrease one is aluminum or some very decrease priced copper alloy. 8 gauge is distinctly thick twine, after all.
Q:6 AWG STRANDED GROUNDING WIRE?
In a nutshell: a) Verify that your service drop has the capacity for the additional load - verify this with your utility. b) If you are planning to install a 200A service in the barn, and you are planning to bury the wire, you will need to use 3-0 wire in a conduit. Use separate conductors. Check with your local electrical inspector, but I do not believe you will need to run a separate ground within the conduit for this application. The code may have changed, however. c) You will need to install a 200A fused safety-switch at the pole, and a new 200A panel in the barn. d) The barn panel will also have a 200A main disconnect breaker in it. e) You will need to install an additional ground-rod (or rods) at the barn panel. 1. DO NOT use old/used wire. 2. Consider running triplex wire overhead as it will be less expensive and equally effective. 3. Get the work inspected by an underwriter - your fire insurance will be voided if you do not. Lastly, it is not rocket science, but the codes and standards that apply are there for a reason - follow them carefully and fully and you will be fine.
Q:Rj-45 connector wiring?
There Are Two Main Wiring Hook-ups That Should Both Work Just Fine.
Q:sub wiring and amp wiring?
The current passing through the wires will cause the wires to heat up if not sufficient guage. Think of the millions of little electrons pushing and shoving back and forth, all this action causes friction on a molecular level and of course we all know friction equals heat. In a bigger guage wire there is more room for the same number of electons. It's really that simple. Use as heavy a guage speaker wire that you can. You will have no signal loss and little heat.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range