Electrical Magnetic Pumps

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
-

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications

Excellent acid and alkali erosion endurance.
Low power,small size.
Portable and endurable

electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Characteristic:

1.Magnetic Driver design without shaft seal.Sealing up completely, There is no leakage of chemical liquid . It's good for the environment,

2.It's apply to Chemical liquid(acid or alkali) transportation.

3.Pump applicable temperature:GFRPP-75 °C , CPVC-80°C,PVDF-90°C. Pump material decided by chemical liquid properties.

electrical magnetic pump, Seal less magnetic pump, permanent magnet water pump Details:


1. Model :MP


2.Pump Material:F-GFRPP  A-CPVC  P-CFRPVDF  E-CFRETFE


3.Power:203-45W  204-65W  255-90W  257-150W  258-260W


4.Connection Type of inlet/outlet :S-screw type   H- Straight pipe type


5.Pump spindle:C-CERAMIC  T-TITANIUM(Ti)  S-SIC


6.Rubber Material :E-EPDM  V-VITON


7.Frequency :5-50Hz  6-60Hz

8.Voltage :V11-110V/220V/1ø  V38-220V/380V/3 ø


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Why should the pump be closed when the centrifugal pump is started?
Centrifugal pump has an important characteristic: when the pressure (head) is very low, the flow will be great, which can be seen from the characteristics of the pump curve. While the pump power is directly proportional to the flow rate, pump start, no pressure in the pipeline, caused by the pump flow, high power pump, and the pump motor, the rotating part from rest to high-speed operation, need a lot of acceleration, it will cause a great starting current
Q:Water pump can not be pumped out, how to maintain water?
Packing overheating:Due to packing too tight, the cooling water can not enter the filler, or the shaft surface damage. Measures for proper relaxation of packing and cleaning of sealing pipe are adopted. Filler wear must be replaced with new ones. Before installation, soak in the oil and rotate it in turn. The incision should be staggered so that water leakage can be reduced. Fill the last lap after installed loading pressed to cover operation for further adjustment of the tightness.
Q:Direct connection pump What is straight pump and non direct pump? What's the difference in structure?
The direct connected pump impeller is directly mounted on the motor shaft, and the non direct connected pump and motor are two shafts, and the two shafts transmit torque through the coupling
Q:What happens when a centrifugal pump is selected?
First of all, the performance curve of the centrifugal pump is similar to the track of the train, and the train can not run away from the track.Secondly, the performance curves of centrifugal pump mainly include flow head curve, efficiency flow curve, power flow curve. When the pump is ready, the curve is fixed. In practical application, after determining the flow rate, the corresponding lift head, efficiency and power (relative to density) are determined. General requirements for centrifugal pump operating in the vicinity at the highest point of efficiency, the efficiency of the flow curve is similar to parabola, so if the actual operation condition deviated from the rated point, whether large or small, will cause the decline in pump efficiency (generally rated value is less than 15%), increased operating costs.
Q:What is the difference between centrifugal pump and self suction pump? Which is better?
Centrifugal pumps are vertical, horizontal, single-stage, multi-stage, single suction, double suction, self suction and other forms. The centrifugal pump drives the water to rotate through the high speed rotating impeller blade, and the water is thrown out so as to achieve the purpose of pumping water. The impeller rotates at high speed, forcing the liquid at the center of the impeller to be removed at high speeds, resulting in a low pressure at the center of the impeller, and the liquid in the lower trough is continuously sucked.
Q:How to distinguish the flow and displacement in the hydraulic pump? What's the difference between the two?
If you're allowed to spend a minute, you can do it 20 times a minute, and that is, the amount of water you sprinkle at a time (1000) is *20.1000 (ML) *20=20000 ml =20 liters, this is the flow,Here is a formula for you to see,Pump displacement * pump speed = flow,
Q:What are the conditions required for hydraulic pumps to complete oil absorption and compression?
There must be one or more sealing volumes, and the volume of work is variable;
Q:What are the advantages and disadvantages of the pump control system and valve control system in the hydraulic system?
Pump control system is generally used for closed systems, the flow of the oil pump changes to control the motor or cylinder actuator action. The utility model has the advantages that the principle is simple, and the power of the engine can be fully utilized. The disadvantage is that the calorific value of larger, relatively poor precision.
Q:What is a solution pump?
Principle and structure features of canned motor pumpThe ordinary centrifugal pump is driven by coupling the pump impeller shaft is connected with the motor shaft, the impeller and the motor rotates while working and shielding pump is a kind of non seal pumps, pump and motor is sealed in a medium filled by pumping the pressure vessel, the pressure vessel only static seal and, by a group of wires to provide a rotating magnetic field and drive the rotor. This structure eliminated the traditional centrifugal pump with a rotary shaft sealing device, it can do no leakage.The pump and motor pump together, motor rotor and pump impeller fixed on the same shaft, use of shielding the rotor and the stator of the motor rotor separated in the medium, its power is transferred to the rotor through the stator magnetic field.
Q:Because the water pressure of the booster pump is not enough, it can not work automatically. It can only be operated by hand. It is inconvenient to use.
The worst case is that the pump is not automatic when it leaves the factory, and no one can say whose product is 100%.But there may be automatic control of this piece, not debugging (this depends on the specific product manual or manufacturer)

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range