• Compensating cable Compensating Conductor System 1
  • Compensating cable Compensating Conductor System 2
  • Compensating cable Compensating Conductor System 3
  • Compensating cable Compensating Conductor System 4
  • Compensating cable Compensating Conductor System 5
Compensating cable Compensating Conductor

Compensating cable Compensating Conductor

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
-
Supply Capability:
1000000meters m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Compensating conductor, compensating cable

Product Description

  The products are applicable for the electric connection between various thermocouples and temperature-indicating instrument with index of S,K,E,T,J and N to improve the thermometric precision.Usually,the PVC insulated and sheathed compensating cable is applied since it's good for its dampproof ante-corrosion and flame-retardant performance.The heat-resistant fluoroplastic insulation and sheath has high temperature-resistant,alkali-resistant acid-resistant,oil-resistant, wear-resistant,age resistant,waterproof and flame-retardant performance.The silicon rubber insulated compensation conductor and compensating cable have oil-resistant,anti-corrosion,age resistant,waterproof and flexible features.The compensating cable is composed of certain quantities of twisted pair type compensating.

Executive Standard:

Apply GB/T4989-94 and JB/T7495-94.   Which is equivalent to IEC584-3 (1989)

Operational Performances:

1.Working temperature:

  General: max. 135°C~ -20°C

  Heat resistant: max. 275°C~ -60°C

  Fire resistant: max. 550°C~ -60°C


2. Minimum bending radius:

  A. PVC insulated and sheathed

  parallel type: not less than 6 times of the thickness of the compensating conductor; twisted pair type: not less than 6 times of the outer diameter of the compensating conductor

  B. Fluoroplastic insulated and sheathed

  parallel type: not less than 10 times of the thickness of the compensating conductor; twisted pair type: not less than 10 times of the outer diameter of the outer diameter of the compensating conductor.

  C. Silicon rubber insulated and sheathed

  parallel type: not less than 4 times of the thickness of the compensating conductor; twisted pair type;not less than 4 times if the outer diameter of the compensating conductor.

  D. For no armored layer compensating cable, not less than 6 times of the outer diameter of the cable. For armor-layered compensating cable, not less than 12 times of the diameter of the cable. For fluoroplastic sheathed and insulated compensating cable, shall not be less than 8 times of the outer diameter of the cable.

Main Technical Data

1.Type, alloy materials and insulation colors

Type of

Compensating Conductor

Equipped Thermocouple

Thermocouple Index

Compensating Conductor

Alloy -wire

Insulation

Layer Coloration

Positive

Negative  

Positive

Negative  

SC

PtRh10-Platinum thermocouple10

S

SPC   Cu

SNC

Cu Ni

Red

Green

RC

PtRh13-Platinum thermocouple13

R

RPC   Cu

RNC Cu Ni

Red

Green

KCA

KCB

KX

Ni Cr- Nisi-loy

Thermocouple

K

KPCA Fe

KPCB Cu

KPX Ni Cr

KNCA Cu Ni

KNCB Cu Ni

KNX Ni Si

Red

Blue

Blue

Black

NC

NX

Ni Cr- Nisi-loy

Thermocouple

N

NPC Fe

NPX

Ni Cr Si

NNC Cu Ni

NNX Ni Si

Red

Grey

Grey

EX

Ni Cr- Copper-nickel

Thermocouple

E

EPX Ni Cr

ENX Cu Ni

Red

Brown

JX

Fe- Copper-nickel

Thermocouple

J

JPX Fe

JNX Cu Ni

Red

Purple

TX

Cu- Copper-nickel

Thermocouple

T

TPX Cu

TNX Cu Ni

Red

White



Note: The letter of type is corresponding to the index of thereto couple, the letter "C" in the second letters represents compensated type compensating conductor, the letter "X" represents prolonged type compensating conductor. The SC type compensating conductor can adapt thereto couple with R type index.


2.Category and grade-mark of compensating conductor

Category

Accuracy Grade and Marking

Sheath Coloration

General

Precision

General

Precision

General

G

B

A

Black

Grey

Heat-resistant

H

B

A

Black

Yellow


3.Thermoelectric potential and allowance

Type

135°C

280°C

(mV)

Thermoelectric

(mV) Allowance

(mV)

Thermoelectric

(mV) Allowance

General        

Precision

General        

Precision

SC

0.645

±0.0379(5°C)

±0.023(3°C)

1.440

±0.0379(5°C)

±0.023(3°C)

BC

  0.333

  -

  -

0.178

  -

  -

KC

  4.095

±0.105(2.5°C)

±0.763(1.5°C)

6.137

±0.201(5°C)

  -

KX

  4.095

±0.104(2.5°C)

±0.065(1.3°C)

8.137

±0.100(2.5°C)

±0.060(1.0°C)

EX

   6.317

±0.570(2.5°C)

±0.102(1.5°C)

13.419

±0.183(2.5°C)

±0.111(1.5°C)

JX

   5.268

±0.134(2.5°C)

±0.081(1.5°C)

10.777

±0.138(2.5°C)

±0.083(1.5°C)

TX

   4.277

±0.047(1.0°C)

±0.024(0.5°C)

9.286

±0.053(1.0°C)

±0.043(0.5°C)


4.The intrinsically safe compensation wire has the following data in addition to the above data

Item

Unit

Data

Working capacity

PF/m

80

Unbalanced capacity

PF/m

1

Distributed inductance

µH/m

0.6

Electrostatic induction (electrostatic voltage 20kV)  

V

1

Electromagnetic interference reduction (interfered magnetic field 400A/m)

mV

5


5.Other performance data

Item

Unit

Technical Data

PVC insulation

F46 insulation

Insulation resistance (20°C)

M .km

25

500

Test voltage

V/min

1000

Flame-retardant character  




FAQ

Example 1: Compensated type and precision grade compensating cable for connection with index K thermocouple: max. application temperature is 200°C,Fluoroplastic insulation flame-retardant temperature is 135°C,PVC sheath is of twisted pair type, aluminum/plastic compound separate shield and copper tape general shield. 7 compensating conductor pairs, conductor nominal section is 1.5mm2, multiple-strand alloy-wire stranding, expressed as: ZR135-KC-HS-FP3VP2 7 X 2 X 1.5

Example 2: Prolonged type and precision grade compensating conductor for connection with index E thermocouple:max. application temperature is 275 0C ,fluoroplastic insulation and sheath, tin-plated copper wire shield, single-strand conductor, section is 2.5mm=, expressed as:

EX-HS-FF46P1 2 X 2.5





Q: Alright, im most likely moving to Germany in December, and im bringing my PS3 over with me. That I bought here in the US.. Is it possible for me to buy the power cable for a PS3 that works in Germany and plug it into my current PS3, or will it short it out?
Hmm i think of I had a similar difficulty as quickly as I did it... You hook up the two ingredient and hdmi cables so which you will discover the reveal then you certainly adjust the output settings to hdmi, after which you will do away with the ingredient cable and it rather is going to likely be advantageous. it may take upto 30seconds for it to alter to hdmi so wait and spot and look ahead to a picture.
Q: I have a 2003 hyundai tiburon and need to know where in the firewall should i drill my hole to run the power cable i know it goes throught the firewall but where if you have ever done this to a tiburon please let me know.
There should already be a hole there.
Q: What I really just want to know is the equation and basic concept on how to determine the optimal length of power cable needed to connect two poles while knowing only the linear density of the cable.It does not matter how much sag is produced because of limitations due to the strength of the power cable.
The web page provides very thorough information and rigorous mathematical treatment relevant to the answer you seek. But it is just too much all at once to digest. So take it piecemeal, one bit at a time! First, you must realize that the sag of the cable is the single most important design parameter and strict attention to cable weight determines the optimal length. The equation of the catenary is the precise model but a parabolic approximation may work. (parabolic approx.) ymax = (3wl?) / ?√(64EA) P = wl?/(8ymax) Where ymax is the maximum sag l is the unstretched length w is the weight/unit length E Youngs modulus A Wire area P axial tension the curve is a parabola, which is a good approximation if the depth of sag is no greater than 1/8th of the span. Use the second equation to derive the induced tension P. H:=WL?/8S S:=WL?/8H L: distance between support S: Sag at mid-span H: tension (horizontal component of tension) The tension depends purely on the loaded geometry and the weight per unit length.
Q: Interested to learn more about selection of Power Cable for Diesel Generating Sets. I have checked out a few websites, but they are all too complicated and ask too many questions. Would like to know if there is a thumb rule for this?
Power cable size will depend on the output current rating of the genset. The conductor size shall be rated for carrying the maximum genset current contnuously and shall be rated for the voltage of the genset.
Q: Also i want to add more power cables to power my hardrives WHAT SHOULD I BUY !!?
Most all motherboards have like 6-10 SATA ports on them, meaning you can connect 6 sata devices (hard drive or dvd drives). Your power supply is what gives you sata power cables. Your psu needs to have the cables already built into it, since the psu has to have the power to actually power all those devices, so it only comes with cables of what its capable of powering. There are 4pin molex adapters which allow you to use a 4pin molex to power sata devices. So you would need to buy sata cables to connect drive to motherboard, and your psu needs to be capable of powering them. You may need to buy a new psu.
Q: Wire with a single core copper wire is good, or multi-core good?
Second, the laying of the bracket, the power cable should be placed in the upper control cable, but 1000 volts below the power cable and control cable can be laid side by side
Q: I have a desktop PC that when turned on the fans works but it won't beep or display anything on screen. But after I unplug both motherboard power connectors and plug them back in, the PC stats working normally, why is that? Oh, and I tried disconnecting only the external power cable, no luck.
Just a guess, but maybe you had a loose connection to the motherboard. Unplugging, and then plugging the cables back in, just made a solid connection.
Q: I have a two year old HP Compaq 6710s laptop, and since yesterday, the second I plug in my power cable, my CPU usage goes up from a normal amount to 100% immediately, making my computer really really slow. Is there anything I can do to fix this? Do you think there's something wrong with the cable or the computer?
In most laptop configurations there are things that are setup to run only when the laptop is plugged in. For example, antivirus scans, adware scans, and such can be set so that they only run when plugged in. It is possible that the unit has been unplugged for awhile and the system suddenly recognizes its plugged in and all the software tries to run thus bogging it down. This is only a hypothesis. The best way to know for sure is to check the Task Manager to find out whats hogging everything. If you don't know, you can open the task manager by either doing CTRL-ALT-DELETE and selecting task manager or by going Start-Run and type in 'taskmgr'. In the window, the applications tab should show what apps are running, the Processes tab should show you all the processes and their memory consumption, and the Performance tab should show you all your memory and CPU untilization. I would start with the Processes tab and see what is consuming the most memory. You can sort by size by clicking on the MemUsage column heading. The processes with the highest memory are the ones to start with. ALso check the Applications tab and see what is running at the time. I would check these while running on battery, and then plug the system in and check them again to see what is different. Whatever has changed is most likely the culprit.
Q: what is the resistance of overhead power cables?
electrical resistance? depends on length, temperature end diameter mechanical...depends on material, steel, copper, aluminium... resistance to corrosion, to fatigue due to vibration from the wind... be more specific Guru
Q: And twisted pair cable parallel to the laying of the same route with 10kVA 380V power cable, the minimum spacing between the two cables should be how much? Knowledge related to integrated wiring. The The The The
PLC and computer communication cable, different manufacturers of PLC connection is not the same

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches