• XLPE/PVC insulated PVC sheath underground power cable System 1
  • XLPE/PVC insulated PVC sheath underground power cable System 2
  • XLPE/PVC insulated PVC sheath underground power cable System 3
XLPE/PVC insulated PVC sheath underground power cable

XLPE/PVC insulated PVC sheath underground power cable

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
20000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

1.PVC insulation CU/AL conductor 
2.multi core armour cable 
3.medium voltage 0.6/1KV 
4.good quality low price 
5.OEM available

1.Standard: GB/T12706/IEC60502 or according to customer’s requirements

2.Voltage Rated:  0.6/1KV, 6KV, 8.7/15KV, 12/20KV, 26/35KV

3.Application: It's applies to electrical power transmission and distribution lines with AC rated voltage up to and including 0.6/1KV. For outdoor and indoor installation in damp and wet locations , laid directly in the ground. 

1,The general type cable are suitable for rated AC voltage 0.6/1KV and below electric lines without flam-retardant or fire-resistance requirements.

2,The flame-retardant type cables are not easy to burn or their flame propagation is limited only in a certain length. . These cables are suitable for high installation density places like power station, subway, tunnel, high-building, large industrial enterprise, oil field and main etc.

3,The fire-resistant cables can not only operate in normal condition, but also can operate in fire during a certain time. These cable are suitable for power station, subway, high human density places where having fire-proof and fire-fight requirements.

4. Operating Features

1, Max .Long-time operating temperature of PVC insulated cable is 70°C

Max .Long-time operating temperature of XLPE insulated cable is 90°C

2.Installing temperature of cable should not be less than 0°C

3, Max short-circuit temperature is not exceed 250°C, Not more than5 Sec.

4,Ambient temperature of installation is not lower than 0°C

5,With good chemical stabilities, such as resistance to acid, alkali, salt, oil and organic solvent and flam-retardant..

6,With light weight, good character, easy to installation and maintenance.

5.Norminal cross section size of conductor: 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2  630mm,

6.Cores available: Single core, 2 cores, 3 cores, 4 cores, 5 cores, 3+1 cores, 3+2 cores, 4+1 cores.

7.This series of Copper Cables  include models as below:

Type

Description

Cu Core

Al Core


VV

VLV

Cu/Al core power cable with PVC insulation PVC sheath

VY

VLY

Cu/Al core power cable with PVC insulation PE sheath

VV22

VLV22

Cu/Al core, steel-belt armored power cable with PVC insulation PVC sheath

VV32

VLV32

Cu/Al core, thin-steel-wire armored power cable with PVC insulation PVC sheath

VV62

VLV62

Cu/Al core, non-magnetic-steel-belt armored power cable with PVC insulation PVC sheath

VV72

VLV72

Cu/Al core, non-magnetic-steel-wire armored power cable with PVC insulation PVC sheath

YJV

YJLV

Cu/Al core power cable with XLPE insulation PVC sheath

YJV22

YJLV22

Cu/Al core, steel-belt armored power cable with XLPE insulation PVC sheath

YJV32

YJLV32

Cu/Al core, thin-steel-wire armored power cable with XLPE insulation PVC sheath

YJV62

YJLV62

Cu/Al core, non-magnetic-steel-belt armored power cable with XLPE insulation PVC sheath

YJV72

YJLV72

Cu/Al core, non-magnetic-steel-wire armored power cable with XLPE insulation PVC sheath

8.Specification Size and Technical Data:

Core number

Nominal Section(mm²)

D.C.Resistance in 20 °c(Ω/km)

 

O.D.(mm)

Reference Weight(Kg/km)

CU

AL

Cu

Al

 

 

 

3 core

1.5

17

10.7

141

2.5

23

17

11.5

180

134

4

30

23

13.6

255

183

6

39

30

14.9

341

228

10

54

41

16.3

470

285

16

71

55

19.6

697

363

25

99

76

23.4

1049

568

35

120

92

25.8

1370

702

70

186

143

28.7

2350

1031

95

227

175

32.8

3144

1355

120

262

203

34.9

3882

1624

185

352

272

43.9

5945

2464

240

420

324

49.2

7647

3132

 

 

 

 

 

 

3+1 core

3×4+1×2.5

31

23

14.2

289

202

3×6+1×4

40

31

15.8

386

262

3×10+1×6

54

42

17.3

548

329

3×16+1×10

72

56

20.5

793

408

3×25+1×16

98

75

24.6

1196

608

3×35+1×16

122

94

26.9

1518

744

3×50+1×25

153

118

27.9

2032

931

3×95+1×50

231

178

35.1

3683

1583

      3×120+1×70

267

207

37.9

4617

1924

3×150+1×70

315

242

41.7

5563

2306

3×185+1×95

362

279

46.4

6929

2854

 

9.Construction:

No: of cable cross: 1 core(Single core),2cores(Double cores),3cores, 4cores(4 equal-section-area cores OR 3 equal-section-area+1 small section area neutral core),5cores(5 3 equal-section-area cores+2 small area neutral cores OR 4 equal-section-area +1 small area neutral cores).We provide armored type and non-armored type for the cables stated above.

About us:

Our company is specialized in conductor ,such as: AAC, AAAC, ACSR/AW, ACS, ABC CABLE, PVC insulated Wire and flexible Eire, PVC insulated Power cable, XLPE insulated power cable


Q:What is the power cable accessories used to do?
The shield has two types of semi-conductive shield and metal shield
Q:What are the advantages and disadvantages of separating 28Vdc, 200A positive power cables and returns into two different harnesses?
WHAT ARE YOU TALKING ABOUT ? ALL DC POWER SOURCE REQUIRES TWO SEPARATED CABLES .
Q:I lost the power cable to my Dell printer 922. Can anyone help me find the cable online, or at a store. Dell told me they don't sell the cable. thanks for the help!! =]
I okorder /.. Parts can also be ordered from Dell by calling 1-800-357-3355. I hope this helps.
Q:The question above relates with the Transpose Line.One of the subtopics under Transmission Line Parameters in Power System.
If the adjacent line induces current in a nearby cable that would be a problem. Transposing results in one section having an induced current with a certain phase but the next section (after the transposition) has an induced current with the opposite phase. Over the length off the cable, the opposing induced currents will cancel each other out.
Q:I'm installing a new hard drive and I need an extra power cable. Thing is, I've only got one in my computer (15 pin SATA) I have a spare SATA port for the data, so that's not a problem. Anyone know of any multipliers or some way i can add an extra power cable?Thanks in advance
Yes, okorder
Q:How do power-station-cable thieves manage to get away without being electrocuted?
Police are hunting for a badly scorched would-be copper thief after finding a hacksaw embedded in an 11,000 volt power cable. The thief also left a lit blow torch at the scene. He is presumed to be badly charred, and not the brightest bulb in the socket. .
Q:There is no load in the middle of the problem added: the laying of the laying, and now the longest cable can do more long
Set-top box on the TV next to a method is to use the network cable connected to the computer, another method is in the set-top box next to a wireless router, the computer can not be used to use the network, if there is no dark Set the network cable, you can also use the power network adapter to the network set-top box out of the network cable connected to the power adapter, through the power line to connect the computer Internet. As long as enough 4M, regardless of rural or urban are the same, I now use the 4M broadband, basically not card.
Q:I know Ethernet cable is much more susceptible to electromagnetic interference than fiber optic cable, but is fiber completely immune to it? I want to wrap a fiber optic cable around a 230 volt power line going through my attic for about 150 feet. Will this cause problems?
Nope my Cable went out sometime between 10:00 and midday in the present day. they're sending a Tech out the following day. I already know what surpassed off. The citizens around the corridor from me moved out and had their cable became off, The goobers became off my cable as a replace as our addresses are one variety off from one yet another. My tackle leads to eight my friends leads to 9.
Q:I have 2 subs and a amp, I have a hi/low converter so it will be able to work. I hooked it all up properly and i noticed i have a empty space on my amp. Its the power control cable. I have no idea how to hook this up to my FACTORY deck. Do i hook it up to the antenna? PLEASE HELP I NEED A ANSWER NOW please thanks-
continuously flow with a smart harness which you would be able to get at radioshack..you'll be able to need an antenna adapter. fool data way and defintitely quite certainly worth the money because it makes it a cinch to place in in sprint or flow reason you do not could decrease your production unit wires....
Q:A pair of Copper wire mains, each of 3.87 sq.cm cross section use to transmit the power, a distance of 915m for 10 hours a day, 80 kilo watt at 200 volts are taken from the mains, find power lost in cable per day at resistivity 1.7 micro ohm.cm.Note: Question is talking about A PAIR OF COPPER WIRE
Power loss per day is meaningless, I assume you mean energy loss per day, or power loss You have to calculate the resistance in the wire. Resistance of a wire in Ω R = ρL/A ρ is resistivity of the material in Ω-m L is length in meters A is cross-sectional area in m? A = πr?, r is radius of wire in m resistivity Cu 17.2e-9 Ω-m 3.87 cm? = 3.87 e-6 m? R = (2*915)(17.2e-9) / (3.87 e-6) = 8.13 ohms 80 kW at 200 volts is a current of 80000/200 = 400 amps You cannot put 400 amps through an 8 ohm resistance, as that requires a voltage of 3200 volts, which we don't have. So the premise of 80 kW is not possible. Perhaps you copied one of the numbers incorrectly. .

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products