Hot Sale High Quality Sewage Pump (WQ-S with CE)
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 100000 set/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Basic Info.
Model NO.:WQS
Application:Sewage Pump
Type:Blade Pump
Material:Cast Iron
Power:Electric
Structure:Single-stage Pump
Theory:Centrifugal Pump
Export Markets:South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Additional Info.
Packing:Wooden Case
Standard:CE
Origin:Taizhou, Zhejiang
Production Capacity:8000PCS /Year
Product Description
Sewage Pump (WQ-S with CE)
Working Conditon
Max. Submerged depth: 5m
Fluid temperature up to +40C
Max ambient temperature +400C
Applicaton&Feature
The pumps are installed a SS cutter on shaft bottom.
And it cut the bigger solids, particles and fibres into small pieces.
They are designed for toilets drainage, agricultrual drainage, septic tank drainage, animal husbandry
Drainage, factory waste water drainage.
Component Material
Pump body: Cast iron
Motor bracket: Cast iron
Impeller: Cast iron
Motor shaft: CS45# or SS
Mechanical seal: Ceramic-graphite or silicon carbide-carbide alloy
Motor Information
380V, 50Hz, 60Hz
Continuous duty.
Insulation calss: E
Protection: IP X8
Model | Power | Speed | discharge | Rated. Flow | Rated Head | efficiency | |
three phase | Kw | Hp | r/min | inch | m3/h | m | % |
WQS7-10-0.75 | 0.75 | 1 | 2900 | 1.5 | 7 | 10 | 51 |
WQS10-10-0.75 | 0.75 | 1 | 2900 | 2 | 10 | 10 | 54 |
WQS10-12-1.1 | 1.1 | 1.5 | 2900 | 2 | 10 | 12 | 51 |
WQS15-8-1.1 | 1.1 | 1.5 | 2900 | 2 | 15 | 8 | 61 |
WQS22-10-1.5 | 1.5 | 2 | 2900 | 2 | 22 | 10 | 65 |
WQS15-15-1.5 | 1.5 | 2 | 2900 | 2 | 15 | 15 | 60 |
WQS15-20-2.2 | 2.2 | 3 | 2900 | 2 | 15 | 20 | 57 |
WQS20-15-2.2 | 2.2 | 3 | 2900 | 2 | 20 | 15 | 64 |
WQS25-13-2.2 | 2.2 | 3 | 2900 | 2.5 | 25 | 13 | 66 |
WQS20-20-3 | 3 | 4 | 2900 | 2 | 20 | 20 | 59 |
WQS25-16-3 | 3 | 4 | 2900 | 2.5 | 25 | 16 | 65 |
WQS35-15-3 | 3 | 4 | 2900 | 2.5 | 35 | 15 | 59 |
WQS25-28-4 | 4 | 5.5 | 2900 | 2.5 | 25 | 28 | 58 |
WQS35-17-4 | 4 | 5.5 | 2900 | 2.5 | 35 | 17 | 59 |
WQS40-15-4 | 4 | 5.5 | 2900 | 3 | 40 | 15 | 71 |
WQS80-9-4 | 4 | 5.5 | 2900 | 4 | 80 | 9 | 72 |
WQS35-22-5.5 | 5.5 | 7.5 | 1450 | 3 | 35 | 22 | 58 |
WQS65-15-5.5 | 5.5 | 7.5 | 1450 | 4 | 65 | 15 | 64 |
WQS100-15-7.5 | 7.5 | 10 | 1450 | 6 | 100 | 15 | 70 |
WQS150-10-7.5 | 7.5 | 10 | 1450 | 4 | 150 | 10 | 75 |
WQS100-18-11 | 11 | 15 | 1450 | 4 | 100 | 18 | 69 |
WQS145-15-11 | 11 | 15 | 1450 | 6 | 145 | 15 | 72 |
WQS80-30-15 | 15 | 20 | 1450 | 4 | 80 | 30 | 58 |
WQS300-10-15 | 15 | 20 | 1450 | 8 | 100 | 10 | 72 |
WQS110-30-18.5 | 18.5 | 25 | 1450 | 6 | 110 | 30 | 72 |
WQS250-15-18.5 | 18.5 | 25 | 1450 | 8 | 250 | 15 | 75 |
WQS300-15-22 | 22 | 30 | 1450 | 6 | 300 | 15 | 76 |
WQS400-10-22 | 22 | 30 | 1450 | 8 | 400 | 10 | 77 |
WQS150-30-30 | 30 | 40 | 1450 | 6 | 150 | 30 | 60 |
WQS200-25-30 | 30 | 40 | 1450 | 6 | 200 | 25 | 62 |
WQS400-15-30 | 30 | 40 | 1450 | 8 | 400 | 15 | 75 |
WQS600-10-30 | 30 | 40 | 1450 | 12 | 600 | 10 | 78 |
WQS150-40-37 | 37 | 50 | 1450 | 6 | 150 | 40 | 63 |
WQS200-30-37 | 37 | 50 | 1450 | 6 | 200 | 30 | 65 |
WQS400-20-37 | 37 | 50 | 1450 | 8 | 400 | 20 | 70 |
- Q:There are second cutting, third cutting, why three times?
- I used to do this job before. After the impeller is cut, the flow and lift will decrease. Sometimes, the same pump will be cut according to the needs of the impeller, so as to meet the actual needs, at this time, with the power of the motor will also be reduced
- Q:What is the difference between the ground pump and the pump in the commercial concrete?
- Move back and forth; pour concrete into a certain area. After the filling is finished, the whole pump truck can be moved to another position quickly
- Q:Why can't the centrifugal pump pump the vacuum?
- Running process: depending on the centrifugal pressure of the liquid in the impeller, the liquid is sucked into the liquid, and the liquid in the pump shell has the conversion of the energy form, so that the fluid can obtain the mechanical energy mainly with the static pressure.The characteristics of the system: the suction diameter than out of large diameter, the general valve installed.
- Q:What are the constant pressure pumps?
- Chlorine booster pumpThe pressure range of chlorine booster pump is large, and different pump can be used to obtain different pressure area. The input air pressure is adjusted and the output pressure is adjusted accordingly. High pressure can be reached, gas 90Mpa. Wide range of flow, for all types of pumps only 0.1Kg pressure can work smoothly, at this time to obtain the minimum flow, adjust the intake volume can be obtained after a different flow. Easy to control, from simple manual control to fully automatic control, can meet the requirements. Automatic restart, regardless of what causes the pressure drop in the pressure loop, will automatically restart to supplement leakage pressure and maintain constant loop pressure. Safe operation, gas driven, no arc and spark can be used in dangerous situations.
- Q:I live on the 8 floor. Often there is no water. Life is very inconvenient. What kind of pump do I have to install? What should I pay attention to when I buy it? What's the pump for that brand? Should it be installed in that position?
- (8) check the suitability of the foundation and whether the size of the foundation corresponds to the size of the pump.(9) find the position of positive pump and motor, pump set and anchor bolt and the inlet and outlet flanges, to ensure that the flange torque of the pump conforms to the standard. Check the inlet and outlet piping before alignment. Make sure the weight of the inlet and outlet pipe does not exert force or torque on the pump. When looking for, should also pay attention to eliminate the pump rotor movement, so as to avoid the end gap error. If checked after the pump is working, it should be carried out under cold condition. It is important to draw attention to the fact that the pump set of the complete set of factory is only rough looking (checked with a ruler) when it is shipped. It may cause displacement when it is transported.
- Q:How many pumps does the 80cm tank use?
- For example, you are 80 cm tank, assuming you are 40 cm wide, the water surface is also 40 cm, then the final count by 80X40X40=128000 cubic centimeter, that is, 128000 ml.
- Q:Which nuclear submarines use the shaftless pump technology?
- Shaftless pumping technology and Simulation of shark skin technology are all the next generation of submarine propulsion technology. At present, there is no submarine in the world.
- Q:What is the displacement of the pump? Flow? What is the volume efficiency and mechanical efficiency of the pump?
- Displacement of a pump: the volume of the discharged liquid calculated by the change in the size of the sealing geometry for each revolution of the hydraulic pump
- Q:Water pump does not produce water, what are the reasons?
- The reason why centrifugal pump does not produce water:1. pump inlet or sink, water tank water shortage.2. water pump pipe blocked or valve not open.
- Q:How many millimeters is the diameter of the water outlet of the four inch pump?
- Here is a 4 inch inch, not rural, 1 inches =25.4 mm, 4 inches is approximately 100mm, with DN100 pipeline.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Hot Sale High Quality Sewage Pump (WQ-S with CE)
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 set
- Supply Capability:
- 100000 set/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products