• PVC insulated wire and cable voltage with rated voltage 450/750V System 1
  • PVC insulated wire and cable voltage with rated voltage 450/750V System 2
PVC insulated wire and cable voltage with rated voltage 450/750V

PVC insulated wire and cable voltage with rated voltage 450/750V

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

The products is suitable for power installation with voltage up to and including 450/750v , household appliances, small electric tools, instruments and lighting etc.    The product is manufactured according to the standards of GB5023-1997《PVC insulated cables for rated voltages bellow 450/750 kV》,JB8734-1998 《PVC insulated cables for rated voltages bellow 450/750kv》, besides, we can produce cables according to IEC standard, BS,DIN and  ICEA upon request. Flame retardant cables, fire-proof cables and nylon-sheathed cables are manufactured.

Typedesignation and main usage  

Type

Designation

Main application

227 IEC 01 (BV)

Single-core non- sheathed cable with solid conductor for general purposes

Fixed laying

BV

Copper conductor PVC insulated wire

BLV

Aluminum conductor PVC insulated wire

227 IEC 05 (BV)

Single-core non-sheathed cable with solid conductor for internal wiring for a conductor temperature of 70

227 IEC 07 (BV-90)

Single-core non- sheathed cable with solid conductor for internal wiring for a conductor temperature of 90

227 IEC 10 (BVV)

Light PVC sheathed flexible cable

BVV

Copper conductor PVC insulated and sheathed round cable

BLVV

Aluminum conductor PVC insulated and sheathed round cable

BVVB

Copper conductor PVC insulated and sheathed flat cable

BLVVB

Aluminum conductor PVC insulated twisted flexible cord for connection

AV

Copper conductor PVC insulated wire for installation

AV-90

Copper conductor PVC insulated wire under the temperature of 90 for installation

AVP

Copper conductor PVC insulated screened wire for installation

AVP-90

Copper conductor PVC insulated screened wire for installation under the temperature of 90

BVR

Copper conductor PVC insulated flexible cable

Soft floor is requested while laying

227 IEC 02 (RV)

Single-core non-sheathed cable with flexible conductor for general purposes

Flexible cable for connection

227 IEC 06 (RV)

Single-core non- sheathed cable with solid conductor for internal wiring for a conductor temperature of 70

227 IEC 08 (RV)

Single –core non-sheathed cable with flexible conductor for internal wiring for a conductor temperature of 90

227 IEC 42 (RVB)

Flat non-sheathed flexible cord

227 IEC 52 (RVV)

Light PVC sheathed flexible cord

227 IEC 53 (RVV)

Ordinary PVC sheathed flexible cord

RVS

Copper conductor PVC insulated twisted flexible cord for connection

AVR

Copper conductor PVC insulated flexible cable for installation

AVR-90

Copper conductor PVC insulated flexible cable for installation under the temperature of 90

AVRB

Cooper conductor PVC insulated flat flexible cable for installation

AVRS

Copper conductor PVC insulated twisted flexible cable for installation

AVVR

 

Copper conductor PVC insulated PVC sheathed flexible cable for installtion

RVP

Cooper conductor PVC insulated sheathed flexible cord

RVP-90

Copper conductor PVC insulated screened flexible cord for a conductor temperature of 90

RVVP

Copper conductor PVC insulated and sheathed screened flexible cable  

RVVP1

Copper conductor PVC insulated and sheathed, twisted  screened flexible cable

 

2、Operating requirement

    Max. permissible continuous operating temperature of the conductor 
    BV-900…………………………
90

    For other types …………………70

    For the fixed installed cables, the ambient temperature under installation shall not bellow 0℃, and the permissible bending radius of cable ≥6D

 



Q:My girlfriend recently damaged (beyond repair) her hp touchsmart tm2 notebook pc Power Cable. I was wondering if laptop power cables are pretty generic, or is there a specific one that i need to order?
I busted my Compaq laptop power cord a few months back and I was able to find another at Walmart to replace it - it set me back $75 which sucked but it was a fairly easy replacement. I imagine you'll find the same to be true with your HP. Good luck.
Q:which cables cant be near each other??(will cause noise radiation if put together)i gotta run some wires through my car and i dont know wich ones to keep away from others. im runnin...4 gauge (eventually will be 2 gauge) power wire for amp2 speaker wires for rear deck speakersrca cables for ampremote turn on wire for amp
yes. run your power cable on the othr side of your car from the rcas. your remote and speaker wire shouldn't affect it
Q:Hello, I am looking to purchase a single power connector for 5 hard drives. I have a modular 1200W power supply, and all i can find on website is these single power connecters that do not even look like they will connect to my power supply. My computer came with power connectors for 4 hard drives in single cables. I do not want to waste another Power supply slot for just 1 more hard drive. Can anybody tell me how to search for this? Thank you.
SATA or EIDE?
Q:NE1 have a surge protector and power filter for there home theatre stuff? If so what is the model and did it make a difference? I have RF grounding problem through my cable and was wondering if the moster cable boxes would help clean up the signal. I have to wrap a wire around the coax cable and ground it to something to make SOME not all of the noise dissappear. (lines rising from bottom to top of picture) Obviously I want a more definate and permant solution. Thanks.
A power conditioner should be a part of any home theater products you want to keep. Monster makes a fine product and backs it up with a connected equipment warranty. But your issue is not power line noise it is a ground problem, get the cable fixed with the appropriate ground clamps,etc.. If you don't have a monster or one that is equivalent you need to get one. I had a lightning strike, not a near strike but a direct one. Took out everything that wasn't hooked up to a monster power center. A few of those fried but monster replaced them, they did exactly what they were designed to do not pass on a surge or die to prevent it. Calling monster was not a problem, and my replacement centers were there within a few days.
Q:i replaced my ps2 power ribbon cable with a slightly diffrent ribbon cable but it had all the connections just like the original one. i plugged in my ps and i heard that slight clicking sound of the electricity entering the ps2's cuircut such as it always has when it was working fine. but when i plug the ps2 in the lights on the power buttons wont come on and they havent come on no matter whitch way i turn the cable. i would really like to get back to KH2 bugt this is getting annoying. what is up with my ps2 that even though everything is connected i cant seem to get the power lights to come on. help!
reassemble it again .pull out out the power cord and reattach it .it happened to me and thats what i did
Q:remove just this cable or use different hd and it works fine, is the hd broken or is it a power consumption by the hd issue? tryed a different psu and its the same problem, unfortunately not got another pc handy to check the hd on. Thanks In advance?
change the hdd interface bus u may get solution otherwise replace it. .in
Q:What is the difference between VV22 and VV62?
Cross-linked power cable heating the main reason there are . the choice of continuous allowable current is less than the load of the maximum continuous current power cable; . the power cable in the implementation of the cable for cold contact, the use of crimping pliers die too large, leading to copper . the air switch input and output and cable copper nose connection, the choice of non-standard flat gasket or no spring gasket; . the air switch input and output side of the cable and cable core crimp is not solid and reliable; When the cable is connected to a strand, the air switch bolts are not tightened. . high-power UPS running, the filter cabinet is not put, n harmonic effects of cable overload, neutral overload, serious lead to cable breakdown, and a fire hazard. . the power cable along the building facade iron cabinet box laying, the surrounding environment is not ventilated, poor heat dissipation. Select the power cable should consider the following factors: . the rated voltage of the cable is greater than or equal to the rated power supply system power supply system; . the cable can continue to allow the current to be equal to or greater than the maximum load current load; . Power supply system short-circuit stability requirements; . according to the length of the cable to determine whether the voltage drop to meet the requirements; . the end of the line minimum short-circuit current should be able to protect the device reliable action. . a high degree of breakdown strength; . low dielectric loss; . a very high insulation resistance; . excellent resistance to discharge performance; . with a certain degree of flexibility and mechanical strength; . long-term stability of insulation.
Q:I installed a 40mm fan on the GPU heatsink that is drawing power from the 12v on the DVD power cable. I'm also thinking of installing a couple 4'' cold cathode lights. How much power can you draw from the 12v DVD power cable before it becomes unstable?
its not smart to attach anything to your 12v power on the dvd line it can cause problems to your 360 and your dvd drive. get your 12v directly from the power socket .
Q:The only thing that im worried about is that my PC power cable has three little slots where you plug it into the brick and my brick only has 2 slots, th cord still fits and powers up my xbox 360 but im just worried about it quot;fryingmy new system. Thanx
Don't do it. The power brick is what powers the console and you need it to properly run it smoothly. Just get a power brick. If you don't have one, go on OKorder.
Q:In the wire and cable factory, will be marked on the wire and cable voltage level, I would like to ask the current market, wire and cable marked on the voltage level which? Such as: BV-450V / 750V. Cable in the order to pay attention to what issues? As well as cable inspection when the attention to what issues? More
Basically are refining, the wax is also used, the high cost of particles

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products